Tomography reconstruction of beams extracted from an ion source

被引:3
|
作者
Saminathan, S. [1 ]
Ames, F. [1 ]
Baartman, R. [1 ]
Marchetto, M. [1 ]
Lailey, O. [2 ]
Mahon, A. [3 ]
机构
[1] TRIUMF, Vancouver, BC V6T 2A3, Canada
[2] Univ Waterloo, Waterloo, ON N2L 3G1, Canada
[3] McGill Univ, Montreal, PQ H3A 2T8, Canada
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 12期
关键词
D O I
10.1063/1.5129786
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Commissioning of the CANREB (CANadian Rare isotope facility with Electron Beam ion source) system and its associated beamlines has recently begun at TRIUMF. At the head of this beamline is an ion source used to produce stable alkaline ions with energy up to 60 keV for the CANREB system. Throughout commissioning, it is essential to have a means of verifying beam quality and ensuring that the required beam parameters along the beamline are met. This is accomplished using tomography reconstruction, which consists of taking one-dimensional scans at different projections and reconstructing an image of the beam in two dimensions using the maximum entropy algorithm. Tomography enables the visualization of the shape of the beam as well as the investigation into the possible presence of aberrations. Initially, tomography reconstruction is performed by using simulated beam profiles at the measurement locations and is then performed by using measured beam profiles. Additionally, these measurements are benchmarked by fitting the initial beam parameters in our beam optics model, and the results are presented. Published under license by AIP Publishing.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Experimental study of Ar+ beams extracted from a cold or hot reflex discharge ion source (CHORDIS)
    Ratschko, D.
    Zhou, B.G.
    Knolle, D.
    Glaser, M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1996, 119 (04): : 549 - 554
  • [22] Plasma potential and energy spread determination using ion beams extracted from an electron cyclotron resonance source
    Harris, P. R.
    Meyer, F. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [23] Optimization of the current extracted from an ultracold ion source
    Debernardi, N.
    van Vliembergen, R. W. L.
    Engelen, W. J.
    Hermans, K. H. M.
    Reijnders, M. P.
    Van der Geer, S. B.
    Mutsaers, P. H. A.
    Luiten, O. J.
    Vredenbregt, E. J. D.
    NEW JOURNAL OF PHYSICS, 2012, 14
  • [24] Experimental study of Ar+ beams extracted from a cold or hot reflex discharge ion source (CHORDIS)
    Ratschko, D
    Zhou, BG
    Knolle, D
    Glaser, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 119 (04): : 549 - 554
  • [25] INERT GAS ION BEAMS FROM A DUOPLASMATRON ION SOURCE
    WELLS, N
    HANLEY, PR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (02): : 203 - &
  • [26] INERT GAS ION BEAMS FROM A DUOPLASMATRON ION SOURCE
    WELLS, N
    HANLEY, PR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1969, NS16 (3P1) : 43 - &
  • [27] OPTICS OF ION-BEAMS OF ARBITRARY PERVEANCE EXTRACTED FROM A PLASMA
    WHEALTON, JH
    JAEGER, EF
    WHITSON, JC
    JOURNAL OF COMPUTATIONAL PHYSICS, 1978, 27 (01) : 32 - 41
  • [28] Properties of a Rubidium Isotope Ion Beam Extracted from a Laser Ion Source
    Tamura, Koji
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (06)
  • [29] Improvement of extracted ion beam from cold cathode Penning ion source
    Radwan, Samah I.
    El-Khabeary, H.
    Helal, A. G.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 351 - 355
  • [30] THE SUPPRESSION OF ELECTRONS EXTRACTED FROM A NEGATIVE-ION SOURCE
    LEA, LM
    HOLMES, AJT
    THORNTON, MF
    NAYLOR, GOR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 409 - 411