A mobile air-cooled absorption chiller of triple-effect

被引:0
|
作者
Millan, MI
机构
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Earlier investigations carried out to determine the available heat from engine exhaust gases of Madrid city buses permitted us to obtain about 15 kWh as result. This heat, supplied to the generator of a mobile air-cooled lithium bromide single-effect absorption chiller (COP=0.6) generated a cooling power of 7 kw, which is not enough to get the comfort conditions in a city bus. Furthermore, the size and weight of the prototype manufactured were larger than those of the mechanical vapor compression system of the same cooling power used until now. In this paper we present an air-cooled triple-effect system, in which the refrigerant absorption has been separated from the heat transfer. Its components are described and the process variables calculated obtaining: maximum boiling temperatures of about 275 degrees C, solution concentrations between 60% and 70%, absolute pressures between 0.10 bar and 12 bar, available heat of about 12 kWh, COP=1.5-1.7. and a cooling capacity between 15 kW and 20 kW. The separation ct the absorption process into two phases has the advantage of a lower absorption temperature than in those with a simultaneous process of mass and heat transfer. On the other hand, the solution concentration in the absorber is also lower, which increases the COP, and lowers the size and weight. The designed system has a power/volume and power/weight ratios on the same order as those of air-cooled mechanical vapor compression systems of the same cooling power.
引用
收藏
页码:355 / 364
页数:10
相关论文
共 50 条
  • [41] Air-cooled condenser
    Phogat, S.S.
    Journal of the Institution of Engineers (India): Mechanical Engineering Division, 1988, 68 pt 6 : 191 - 195
  • [42] AIR-COOLED TURBOGENERATORS
    ALWERS, E
    MERZ, K
    ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1977, 98 (10): : 661 - 661
  • [43] Air-cooled extruders
    Mod Plast, 2 (81):
  • [44] AIR-COOLED EQUIPMENT
    不详
    COKE & CHEMISTRY USSR, 1968, (05): : 52 - &
  • [45] Adsorption-absorption cascading triple-effect refrigeration cycle
    Jiang, Zhoushu
    Wang, Ruzhu
    Lu, Yunzhuang
    Shao, Yuan
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2002, 53 (06): : 566 - 571
  • [46] Simulation and analysis of triple-effect lithium bromide absorption cycles
    Wang, Leilei
    You, Shijun
    Sun, Hejiang
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1501 - 1508
  • [47] Simulation of an air-cooled solar-assisted absorption air conditioning system
    Alva, LH
    González, JE
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03): : 276 - 282
  • [48] Modelling and analysis of air-cooled reciprocating chiller and demand energy savings using passive cooling
    Chowdhury, Ashfaque Ahmed
    Rasul, M. G.
    Khan, M. M. K.
    APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1825 - 1830
  • [49] Application of an adaptive neuro-fuzzy inference system for the performance analysis of an air-cooled chiller
    Lee, Chengwen
    Chang, Yungchung
    Lu, Yunting
    ENERGY SCIENCE AND APPLIED TECHNOLOGY (ESAT 2016), 2016, : 269 - 275
  • [50] Energy simulation of sustainable air-cooled chiller system for commercial buildings under climate change
    Yu, F. W.
    Chan, K. T.
    Sit, Rachel K. Y.
    Yang, J.