Platform switching and matrix metalloproteinase-8 levels in peri-implant sulcular fluid

被引:9
|
作者
Canullo, Luigi
Iannello, Giuliano
Netuschil, Lutz [1 ]
Jepsen, Soren [2 ]
机构
[1] Univ Dresden, Dept Periodontol, Dresden, Germany
[2] Univ Bonn, Dept Periodontol, Bonn, Germany
关键词
bone loss; collagenases; dental implants; implant design; MMP-8; platform switching; GINGIVAL CREVICULAR FLUID; CRESTAL BONE CHANGES; TITANIUM IMPLANTS; BIOLOGIC WIDTH; HISTOMETRIC EVALUATION; SUBMERGED IMPLANTS; MMP-8; COLLAGENASE-2; PERIODONTITIS; INFLAMMATION;
D O I
10.1111/j.1600-0501.2011.02175.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The concept of platform switching has been introduced to implant therapy, however long-term data are sparse. The aim of this study was to biochemically investigate the inflammatory response mediated by MMP-8 to platform switching after 3 years of loading, in order to understand the long-term effect of implant/abutment mismatching on peri-implant health. Methods: A total of 70 implants had been inserted in the posterior maxilla in 26 patients and were randomly assigned to one of the four treatment regimens (implant diameter 3.8 [control group], 4.3 [Test group 1, T-1], 4.8 [Test group 2, T-2] and 5.5mm [Test group 3, T-3]). All implants were restored using a 3.8mm abutment. In the test groups, this restoration resulted in a mismatching of 0.25-0.85mm of implant-abutment diameters. Results: Thirty-six months after prosthetic rehabilitation, peri-implant sulcular fluid samples were taken from two aspects of all implants and from periodontally healthy adjacent teeth. Samples were processed in a conventional ELISA using monoclonal antibodies recognizing the active entity of MMP-8. In the test groups, MMP-8 mean values were 2.76 ng for T-1 (SD: 2.91), 3.30 ng for T-2 (SD: 1.94) and 3.18 ng for T-3 (SD: 2.46). For the control group, MMP-8 mean value was 3.6 ng (SD: 2.23), whereas 3.38 ng (SD: 2.2) was recorded at the adjacent teeth. There were no statistically significant differences in MMP-8 values between the groups (P = 0.113, Kruskal-Wallis). Conclusions: The presence of an implant/abutment mismatching specific for this prosthetic concept is compatible with long-term peri-implant health as demonstrated by analysis of a sensitive biomarker of the peri-implant inflammatory response.
引用
收藏
页码:556 / 559
页数:4
相关论文
共 50 条
  • [21] Correlation between peri-implant sulcular fluid rate and expression of collagenase2 (MMP8)
    Janska, Emilia
    Mohr, Barbara
    Wahl, Gerhard
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (02) : 261 - 266
  • [22] Osteoprotegerin levels in peri-implant crevicular fluid
    Arikan, Fatih
    Buduneli, Nurcan
    Kutukculer, Necil
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) : 283 - 288
  • [23] Correlation between peri-implant sulcular fluid rate and expression of collagenase2 (MMP8)
    Emilia Janska
    Barbara Mohr
    Gerhard Wahl
    Clinical Oral Investigations, 2016, 20 : 261 - 266
  • [24] Levels of procalcitonin in saliva and peri-implant crevicular fluid in patients with peri-implant diseases and health
    Algohar, Ahmed
    Alqerban, Ali
    ARCHIVES OF ORAL BIOLOGY, 2020, 120
  • [25] The evaluation of peri-implant sulcus fluid osteocalcin, osteopontin, and osteonectin levels in peri-implant diseases
    Cakal, Oya Turkoglu
    Efeoglu, Candan
    Bozkurt, Emir
    JOURNAL OF PERIODONTOLOGY, 2018, 89 (04) : 418 - 423
  • [26] Cortisol Levels in the Peri-implant Sulcular Fluid of Type-2 Diabetic and Non-diabetic Patients with Peri-implantitis
    Ali, Dena
    Baskaradoss, Jagan Kumar
    Joseph, Bobby Karingada
    ORAL HEALTH & PREVENTIVE DENTISTRY, 2022, 20 (01) : 219 - 225
  • [27] Peri-implant phenotype, calprotectin and MMP-8 levels in cases diagnosed with peri-implant disease
    Onder, Yasemin Beliz
    Alpaslan, Nazli Zeynep
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (07)
  • [28] Influence of different forms and materials (zirconia or titanium) of abutments in peri-implant soft-tissue healing using matrix metalloproteinase-8: A randomized pilot study
    Kumar, Yogesh
    Jain, Veena
    Chauhan, Shyam Singh
    Bharate, Vinayak
    Koli, Dheeraj
    Kumar, Manish
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04): : 475 - 480
  • [29] Comparison of cotinine levels in the peri-implant sulcular fluid among cigarette and waterpipe smokers, electronic-cigarette users, and nonsmokers
    Alqahtani, Fawaz
    Alqahtani, Mana
    Albaqawi, Ahmed Heji
    Al-Kheraif, Abdulaziz A.
    Javed, Fawad
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 702 - 707
  • [30] The relationship between amniotic fluid matrix metalloproteinase-8 and funisitis
    Park, JS
    Romero, R
    Yoon, BH
    Moon, JB
    Oh, SY
    Han, SY
    Ko, EM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (05) : 1156 - 1161