The Zymark MultiDose is a non-robotic dissolution workstation for the automation of USP Apparatus 2 (paddle) dissolution profiles. MultiDose can automate up to 8 standard 6-vessel dissolution tests without operator assistance. Analysis can be performed using on-line UV or offline by HPLC. MultiDose frees up analyst's time by automating crucial steps in dissolution testing such as; media sparging (using helium), preheating and dispensing into vessels; verification of vessel temperature; dropping of dosage forms (either in batch mode ''all at the same time'' or serial mode ''one at a time''); collection and filtration of sample aliquots at prescribed times; and cleaning of vessels at the end of the test. These steps can be repeated for up to 8 batches of tablets.
引用
收藏
页码:533 / 542
页数:10
相关论文
共 50 条
  • [41] Automated testing using PXI and IVI technologies
    Bingham, EA
    AUTOTESTCON 2004, PROCEEDINGS: TECHNOLOGY AND TRADITION UNITE IN SAN ANTONIO, 2004, : 30 - 36
  • [42] Automated Regression Testing using Symbolic Execution
    Barisas, D.
    Milasius, T.
    Bareisa, E.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2011, (06) : 101 - 105
  • [43] Accelerated Dissolution Testing for Controlled Release Microspheres Using the Flow-Through Dissolution Apparatus
    Collier, Jarrod W.
    Thakare, Mohan
    Garner, Solomon T.
    Israel, Bridg'ette
    Ahmed, Hisham
    Granade, Saundra
    Strong, Deborah L.
    Price, James C.
    Capomacchia, A. C.
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2009, 14 (01) : 9 - 17
  • [44] Dissolution testing of a poorly soluble compound using the flow-through cell dissolution apparatus
    Bhattachar, SN
    Wesley, JA
    Fioritto, A
    Martin, PJ
    Babu, SR
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 236 (1-2) : 135 - 143
  • [45] AN AUTOMATED APPARATUS FOR DISSOLUTION STUDIES
    RICHTER, A
    MYHRE, B
    KHANNA, SC
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1969, 21 (07) : 409 - &
  • [46] Hydrodynamic Influences on Dissolution Testing Using Flow Channel Apparatuses
    Mattusch, Amelie
    Meurers, Alexandra
    Hense, Niklas
    Bartsch, Jens
    Thommes, Markus
    CHEMICAL ENGINEERING & TECHNOLOGY, 2025, 48 (02)
  • [47] Technical Note: Impact of Using Plastic Vessels in Dissolution Testing
    Shetgar, Sanjay S.
    DISSOLUTION TECHNOLOGIES, 2010, 17 (01): : 39 - 39
  • [48] CALORIMETRIC DISSOLUTION TESTING
    IBA, K
    ARAKAWA, E
    MORRIS, T
    CARSTENSEN, JT
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1991, 17 (01) : 77 - 89
  • [49] Challenges in Dissolution Testing
    Marques, Margareth R. C.
    Brown, William
    Giancaspro, Gabriel
    Davydova, Natalia
    Chang, Edith
    Fringer, Jeanne
    Hauck, Walter
    DeStefano, Anthony
    DISSOLUTION TECHNOLOGIES, 2012, 19 (03): : 39 - 41
  • [50] The fundamentals of dissolution testing
    Thomas, Felicity
    Pharmaceutical Technology, 2019, 43 (10) : 44 - 47