Simultaneous determination of Cd, Cu, Mn, Ni, Pb and Zn in nail samples by inductively coupled plasma mass spectrometry (ICP-MS) after tetramethylammonium hydroxide solubilization at room temperature: Comparison with ETAAS

被引:103
|
作者
Batista, Bruno L. [1 ]
Rodrigues, Jairo L. [1 ]
Nunes, Juliana A. [1 ]
Tormen, Luciano [2 ]
Curtius, Adilson J. [2 ]
Barbosa, Fernando, Jr. [1 ]
机构
[1] Univ Sao Paulo, Fac Ciencias Farmaceut Ribeirao Preto, Dept Anal Clin Toxicol & Bromatol, Lab Toxicol & Essencial Metais, BR-14040903 Ribeirao Preto, SP, Brazil
[2] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
基金
巴西圣保罗研究基金会;
关键词
ICP-MS; ETAAS; nail samples; trace elements; rapid determination; tetramethylammonium hydroxide;
D O I
10.1016/j.talanta.2008.03.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method is described for the determination of Cd, Cu, Mn, Ni, Ph and Zn in nails by using inductively coupled plasma mass spectrometry (ICP-MS) or electrothermal atomic absorption spectrometry (ETAAS). Prior to analysis, 10-20 mg of nail samples were accurately weighed into (15 mL) conical tubes. Then, 1 mL of 25% (w/v) tetra methylammonium hydroxide (TMAH) solution was added to the samples, incubated at room temperature overnight and then further diluted to 10 ml, with 1 % (v/v) HNO3. After that, samples were directly analyzed. Rhodium was used as internal standard for ICP-MS analysis. Method detection limits (3 s, n = 20) were 0.1, 3.0, 1.0, 4.5, 1.5, 5.0 ng g(-1) for Cd, Cu, Mn, Ni, Ph and Zn, respectively for ICPMS, and 24, 26, 30,143,130 and 1000ng g(-1), respectively for ETAAS. The key issue addressed here is the elimination of the acid digestion prior to analysis. Moreover, with the use of the proposed method there is a considerable improvement in the sample throughput comparing to the traditional methods using microwave-assisted acid sample digestion prior to analysis. For validation purposes, six ordinary nail samples were solubilized and then directly analyzed by ICP-MS and ETAAS, with no statistical difference between the two techniques at 95% level on applying the t-test. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:575 / 579
页数:5
相关论文
共 50 条
  • [21] Determination of selenium in red blood cells by inductively coupled plasma mass spectrometry (ICP-MS) after microwave digestion
    Tinggi, U
    Gianduzzo, T
    Francis, R
    Nicol, D
    Shahin, M
    Scheelings, P
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 259 (03) : 469 - 472
  • [22] The Use Of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) For The Determination Of Toxic And Essential Elements In Different Types Of Food Samples
    Voica, C.
    Dehelean, A.
    Kovacs, M. H.
    PROCESSES IN ISOTOPES AND MOLECULES (PIM 2011), 2012, 1425 : 110 - 113
  • [23] Determination of selenium in red blood cells by inductively coupled plasma mass spectrometry (ICP-MS) after microwave digestion
    U. Tinggi
    T. Gianduzzo
    R. Francis
    D. Nicol
    M. Shahin
    P. Scheelings
    Journal of Radioanalytical and Nuclear Chemistry, 2004, 259 : 469 - 472
  • [24] The use of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of toxic and essential elements in different types of food samples
    Nardi, Elene P.
    Evangelista, Fabio S.
    Tormen, Luciano
    SaintPierre, Tatiana D.
    Curtius, Adilson J.
    de Souza, Samuel S.
    Barbosa, Fernando, Jr.
    FOOD CHEMISTRY, 2009, 112 (03) : 727 - 732
  • [25] DISTRIBUTION OF MG, FE, CU AND ZN IN GLIOBLASTOMA, MENINGIOMA I AND II USING INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP-MS)
    Mudariki, T.
    Lea, R. W.
    Ashton, K.
    Dawson, T.
    Davis, C.
    Smith, J. A.
    NEURO-ONCOLOGY, 2015, 17 : 4 - 5
  • [26] Analysis of Cu, Co, V and Zn in coastal waters of the East China Sea by inductively coupled plasma mass spectrometry (ICP-MS)
    Rujun Yang
    Yutong Ning
    Aibin Zhang
    Yan Li
    Han Su
    Journal of Ocean University of China, 2016, 15 : 825 - 834
  • [27] Analysis of Cu,Co,V and Zn in Coastal Waters of the East China Sea by Inductively Coupled Plasma Mass Spectrometry(ICP-MS)
    YANG Rujun
    NING Yutong
    ZHANG Aibin
    LI Yan
    SU Han
    Journal of Ocean University of China, 2016, 15 (05) : 825 - 834
  • [28] Analysis of Cu, Co, V and Zn in Coastal Waters of the East China Sea by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
    Yang Rujun
    Ning Yutong
    Zhang Aibin
    Li Yan
    Su Han
    JOURNAL OF OCEAN UNIVERSITY OF CHINA, 2016, 15 (05) : 825 - 834
  • [29] Determination of Cr, Mn, Fe, Cu, Zn, As, Se, Cd, Hg and Pb in ginseng by inductively coupled plasma mass spectroscopy
    Chen, Bin
    Yan, Zhen
    Zhuang, Zhi-Xia
    Wang, Xiao-Ru
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 1999, 20 (5 Suppl):
  • [30] Determination of Cd, Cu, Zn and Pb in rice flour reference materials by isotope dilution inductively coupled plasma mass spectrometry
    Park, CJ
    Suh, JK
    Lee, KW
    Lee, SH
    ANALYTICAL SCIENCES, 1997, 13 : 429 - 432