Corrosion evaluation of post-tensioned tendons on the Mid-Bay Bridge in Destin, Florida

被引:0
|
作者
Venugopalan, S [1 ]
Hartt, WH [1 ]
Powers, RG [1 ]
机构
[1] Florida Atlantic Univ, Dept Ocean Engn, Dania, FL USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion and corrosion-related tendon failures have been disclosed on several segmental box girder bridges in Florida. One of these was the Mid-Bay Bridge near Destin where as many as 11 tendons were replaced. Additionally, many other tendons exhibited cracking of the polyethylene duct. The visual inspection of this bridge revealed (1) corrosion of tendons and individual wires that ranged from minimal to severe, (2) presence of broken wires, and (3) cracking of the polyethylene duct. Extensive cracking of the polyethylene ducts was not the primary cause of tendon corrosion problems. However, it does serve as a corrosion promoter by providing greater moisture, oxygen, and chloride access to the steel. Based upon the various field and laboratory findings, a mechanism of tendon corrosion is proposed. Susceptibility of a particular tendon to deterioration by this cause should vary depending upon the extent to which deleterious conditions are present.
引用
收藏
页码:243 / 253
页数:11
相关论文
共 50 条
  • [31] Investigation of concrete beams post-tensioned with unbonded CFRP tendons
    Bakis, CE
    Bhat, BB
    Giernacky, RG
    Boothby, TE
    ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, 2000, : 413 - 420
  • [32] TEST OF POST-TENSIONED FLAT-PLATE WITH BANDED TENDONS
    BURNS, NH
    HEMAKOM, R
    JOURNAL OF STRUCTURAL ENGINEERING, 1985, 111 (09) : 1899 - 1915
  • [33] Indirect Impedance for Corrosion Detection of External Post-tensioned Tendons: 2. Multiple Steel Strands
    Alexander, Christopher L.
    Orazem, Mark E.
    CORROSION SCIENCE, 2020, 164
  • [34] Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 2: Segregated Grout with Elevated Sulfate Content
    Permeh, S.
    Vigneshwaran, K. K. Krishna
    Echeverria, M.
    Lau, K.
    Lasa, I.
    CORROSION, 2018, 74 (04) : 457 - 467
  • [35] Condition survey and evaluation of an early post-tensioned bridge verified after removal
    Vogel, Thomas
    Fricker, Stephan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2014, 10 (03) : 359 - 374
  • [36] Cracking of the End Diaphragm of a Post-tensioned Beam Bridge
    Kuusela, Mikko
    Asp, Olli
    Laaksonen, Anssi
    NORDIC CONCRETE RESEARCH, 2019, 60 (01): : 89 - 104
  • [37] Inspection of tendons in post-tensioned concrete using guided ultrasonic waves
    Pavlakovic, B.
    Lowe, M.J.S.
    Cawley, P.
    Insight: Non-Destructive Testing and Condition Monitoring, 1999, 41 (07):
  • [38] Structural Responses of External Post-Tensioned Tendons to Increasing Localized Damage
    Lee, Jun Ki
    ACI STRUCTURAL JOURNAL, 2017, 114 (05) : 1155 - 1166
  • [39] In Situ Verification of Tendons of First Segmental Post-Tensioned Road Bridges
    Kralovanec, Jakub
    Moravcik, Martin
    Zahuranec, Michal
    Bahleda, Frantisek
    CIVIL AND ENVIRONMENTAL ENGINEERING, 2024, 20 (02) : 920 - 932
  • [40] Repair and retrofitting of structural RC walls by means of post-tensioned tendons
    Marini, A.
    Riva, P.
    Fattori, L.
    FRACTURE MECHANICS OF CONCRETE AND CONCRETE STRUCTURES, VOLS 1-3: VOL 1: NEW TRENDS IN FRACTURE MECHANICS OF CONCRETE; VOL 2: DESIGN, ASSESSMENT AND RETROFITTING OF RC STRUCTURES; VOL 3: HIGH-PERFORMANCE CONCRETE, BRICK-MASONRY AND ENVIRONMENTAL ASPECTS, 2007, 1-3 : 1157 - +