Inter-laboratory Variability of Current Immunoassay Methods for Tacrolimus among Japanese Hospitals

被引:17
|
作者
Miura, Masatomo [1 ]
Masuda, Satohiro [2 ]
Egawa, Hiroto [3 ]
Yuzawa, Kenji [4 ]
Matsubara, Kazuo [5 ]
机构
[1] Akita Univ Hosp, Dept Pharm, 1-1-1 Hondo, Akita 0108543, Japan
[2] Kyushu Univ Hosp, Dept Pharm, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Tokyo Womens Med Univ, Dept Surg, Shinjuku Ku, 8-1 Kawada Cho, Tokyo 1628666, Japan
[4] Natl Hosp Org, Mito Med Ctr, Dept Transplantat Surg, 280 Sakuranosato, Ibaraki, Ibaraki 3119193, Japan
[5] Kyoto Univ Hosp, Dept Clin Pharmacol & Therapeut, Sakyo Ku, Kyoto 6068501, Japan
关键词
tacrolimus; immunoassay; coefficient of variation; quality control; SOLID-ORGAN TRANSPLANTATION; COLUMN-MEDIATED IMMUNOASSAY; TANDEM MASS-SPECTROMETRY; ASSAY; BLOOD; LIVER; RECIPIENTS; ANALYZER; KIDNEY;
D O I
10.1248/bpb.b16-00249
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The aim of this study was to assess inter-hospital laboratory variability (coefficient of variation; CV) of immunoassay methods for tacrolimus and the comparability of control samples and results obtained by immunoassay measurements. One hundred seven hospital laboratories routinely performing therapeutic drug monitoring (TDM) of tacrolimus participated in the study. Thirteen spiked samples with known tacrolimus concentrations in the range of 0-26.0 ng/mL were prepared. Each spiked sample was analyzed according to the manufacturer's instructions using an affinity column-mediated immunoassay (ACMIA) on a Dimension analyzer, the enzyme multiplied immunoassay technique (EMIT) on a Viva-E (R) analyzer, a chemiluminescent enzyme immunoassay (CLIA) on the Architect (R) system, and the electro-chemiluminescence immunoassay (ECLIA) on a cobas (R) analyzer. The 20% coefficient of variation values for the CLIA, ACMIA, EMIT, and ECLIA assays in the hospital laboratories were 1.82, 5.36, 4.59, and 0.89 ng/mL, respectively. CLIA and ECLIA had positive biases at concentrations of tacrolimus above 12 ng/mL relative to the spiked concentration, whereas the assay bias for ACMIA tended to be more negative at concentrations of tacrolimus above 6ng/mL. EMIT had positive biases over the wide concentration range of 0.0-26.0 ng/mL (mean of mean errors 1.224). CLIA and ECLIA provided adequate precision at the target tacrolimus concentration of 3.0 ng/mL, whereas ACMIA and EMIT were unable to respond to target concentrations between 3.0 and 5.0ng/mL for renal transplant recipients. Appropriate assessment of tacrolimus concentration by an assay having higher sensitivity, precision, and accuracy is necessary to ensure long-term survival of transplant recipients receiving tacrolimus.
引用
收藏
页码:1331 / 1337
页数:7
相关论文
共 50 条
  • [31] INTER-LABORATORY VARIABILITY IN PTH MEASUREMENT AND ATTAINMENT OF ANALTIC PERFORMANCE GOALS
    Sarabia, Sam
    Collier, Christine
    Holden, Rachel
    Turner, Mandy
    White, Christine
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33 : 163 - 163
  • [32] EEC INTER-LABORATORY TESTS ON METHODS OF ANALYSIS OF FIBER MIXTURES
    WORTMANN, FJ
    ZAHN, H
    HOCKER, H
    JOURNAL OF THE TEXTILE INSTITUTE, 1989, 80 (04) : 617 - 619
  • [33] RE-APPRAISAL OF INTER-LABORATORY VARIABILITY IN ANTIEPILEPTIC DRUG DETERMINATIONS
    PIPPENGER, CE
    PARISKUTT, H
    PENRY, JK
    CLINICAL CHEMISTRY, 1978, 24 (06) : 1050 - 1050
  • [34] Inter-laboratory consistency and variability in the buccal micronucleus cytome assay depends on biomarker scored and laboratory experience: results from the HUMNxl international inter-laboratory scoring exercise
    Bolognesi, Claudia
    Knasmueller, Siegfried
    Nersesyan, Armen
    Roggieri, Paola
    Ceppi, Marcello
    Bruzzone, Marco
    Blaszczyk, Ewa
    Mielzynska-Svach, Danuta
    Milic, Mirta
    Bonassi, Stefano
    Benedetti, Danieli
    Da Silva, Juliana
    Toledo, Raphael
    Favero Salvadori, Daisy Maria
    Groot de Restrepo, Helena
    Filipic, Metka
    Hercog, Klara
    Aktas, Ayca
    Burgaz, Sema
    Kundi, Michael
    Grummt, Tamara
    Thomas, Philip
    Hor, Maryam
    Escudero-Fung, Maria
    Holland, Nina
    Fenech, Michael
    MUTAGENESIS, 2017, 32 (02) : 257 - 266
  • [35] INTER-LABORATORY STUDY WITH REGARD TO THE VARIABILITY OF 3 AGLIME ANALYSIS-METHODS, INCLUDING A RESIN SUSPENSION METHOD
    BORNMAN, JJ
    COETZEE, JEK
    VANVUUREN, JAJ
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1988, 19 (03) : 299 - 310
  • [36] Identification of atypical Aeromonas salmonicida:: Inter-laboratory evaluation and harmonization of methods
    Dalsgaard, I
    Gudmundsdóttir, BK
    Helgason, S
    Hoie, S
    Thoresen, OF
    Wichardt, UP
    Wiklund, T
    JOURNAL OF APPLIED MICROBIOLOGY, 1998, 84 (06) : 999 - 1006
  • [37] APPLICATION OF TWO ROBUST METHODS IN INTER-LABORATORY COMPARISONS WITH SMALL SAMPLES
    Volodarsky, Evgeniy T.
    Warsza, Zygmunt L.
    ADVANCED MATHEMATICAL AND COMPUTATIONAL TOOLS IN METROLOGY AND TESTING X, 2015, 86 : 385 - 391
  • [38] A safe bet? Inter-laboratory variability in behaviour-based severity assessment
    Jirkof, Paulin
    Abdelrahman, Ahmed
    Bleich, Andre
    Durst, Mattea
    Keubler, Lydia
    Potschka, Heidrun
    Struve, Birgitta
    Talbot, Steven R.
    Vollmar, Brigitte
    Zechner, Dietmar
    Haeger, Christine
    LABORATORY ANIMALS, 2020, 54 (01) : 73 - 82
  • [39] METHODS FOR THE DETECTION OF THERMOTOLERANT CAMPYLOBACTERS IN FOODS - RESULTS OF AN INTER-LABORATORY STUDY
    SCOTTER, SL
    HUMPHREY, TJ
    HENLEY, A
    JOURNAL OF APPLIED BACTERIOLOGY, 1993, 74 (02): : 155 - 163
  • [40] Using Bayes methods and mixture models in inter-laboratory studies with outliers
    Garritt L. Page
    Stephen B. Vardeman
    Accreditation and Quality Assurance, 2010, 15 : 379 - 389