Accuracy of full-arch digital implant impressions taken using intraoral scanners and related variables: A systematic review

被引:0
|
作者
Zhang, Yi-Jie [1 ,2 ]
Shi, Jun-Yu [1 ,2 ]
Qian, Shu-Jiao [1 ,2 ]
Qiao, Shi-Chong [1 ,2 ]
Lai, Hong-Chang [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Natl Clin Res Ctr Oral Dis, Dept Implant Dent,Coll Stomatol,Sch Med,Shanghai, 639 Zhizaoju Rd, Shanghai 200011, Peoples R China
[2] Shanghai Res Inst Stomatol, 639 Zhizaoju Rd, Shanghai 200011, Peoples R China
基金
中国国家自然科学基金;
关键词
accuracy; dental impression technique; digital impressions; edentulous; intraoral scanner; IN-VITRO; CONVENTIONAL IMPRESSION; MULTIPLE IMPLANTS; PRECISION; TECHNOLOGY; PROSTHESES; RESTORATIONS; DIGITIZATION; FABRICATION; BODIES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the accuracy of full-arch digital implant impressions taken using intraoral scanners and analyse the related variables. Materials and methods: An electronic search of studies on the accuracy of digital implant impressions in fully edentulous arches from 1 January 2012 to 29 February 2020 was conducted in PubMed, EMBASE and the Cochrane Library. Only peer-reviewed experimental or clinical studies written in English were included. Studies assessing the accuracy of restorations, case reports, clinical reports, technical reports and reviews were excluded. The literature screening, article reading and assessment of risk of bias were carried out by two reviewers. The data on the study characteristics, accuracy outcomes and investigated variables were extracted. Results: After removal of duplicates, a total of 166 studies were identified, of which 42 were initially selected for full-text reading and 30 were included in the final analysis (29 in vitro studies and one in vivo study). The trueness of digital implant impressions ranged from 7.6 to 731.7 mu m, and the precision ranged from 15.2 to 204.2 mu m. Angular deviations were between 0.13 and 10.01 degrees. Considering 100 mu m and 0.4 degrees as clinically acceptable levels of deviation, 18 studies reported linear/distance/3D deviations larger than 100 mu m and only two studies reported angular deviations below 0.4 degrees. The effect of interimplant distance/length of the arch scanned/scanning sequence/scanning range/implant position (nine studies), implant angulation (ten studies), implant depth (five studies), implant connection (two studies), operator experience (six studies), scan body type (three studies), intraoral scanner type (six studies), scanning strategy (two studies) and modification technique (three studies) was investigated. Conclusions: Based on the results of the included studies, full-arch digital implant impressions taken using intraoral scanners are not sufficiently accurate for clinical application. Accuracy varies greatly with interimplant distance, scan body type, intraoral scanner type and operator experience, whereas implant angulation, implant connections and implant depth have no effect. The effects of scanning strategy and modification technique need further investigation.
引用
收藏
页码:157 / 179
页数:23
相关论文
共 50 条
  • [1] Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners
    Siadat, Hakimeh
    Chitsaz, Foujan
    Zeighami, Somayeh
    Esmaeilzadeh, Alireza
    [J]. CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (02):
  • [2] Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence
    Goracci, Cecilia
    Franchi, Lorenzo
    Vichi, Alessandro
    Ferrari, Marco
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (04) : 422 - 428
  • [3] Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions
    Akkal, Ozcan
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 179 - 188
  • [4] Linear Accuracy of Intraoral Scanners for Full-Arch Impressions of Implant-Supported Prostheses: A Systematic Review and Meta-Analysis
    Floriani, Franciele
    Lopes, Guilherme Carpena
    Cabrera, Alexandre
    Duarte, Wagner
    Zoidis, Panagiotis
    Oliveira, Dayane
    Rocha, Mateus Garcia
    [J]. EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 964 - 973
  • [5] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694
  • [6] Accuracy of full-arch scans using intraoral scanners
    Sebastian B. M. Patzelt
    Archontia Emmanouilidi
    Susanne Stampf
    Joerg R. Strub
    Wael Att
    [J]. Clinical Oral Investigations, 2014, 18 : 1687 - 1694
  • [7] Accuracy of digital implant impressions with intraoral scanners. A systematic review
    Rutkunas, Vygandas
    Geciauskaite, Agne
    Jegelevicius, Darius
    Vaitiekunas, Mantas
    [J]. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 : 101 - 120
  • [8] EPA Consensus Project Paper: Accuracy of Photogrammetry Devices, Intraoral Scanners, and Conventional Techniques for the Full-Arch Implant Impressions: A Systematic Review
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Mischitz, Ingrida
    Mijiritsky, Eitan
    Huber, Sandra
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2023,
  • [9] In vivo full-arch accuracy of intraoral scanners: a narrative review
    Jennes, Marie-Elise
    Soetebeer, Maren
    Beuer, Florian
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (01) : 9 - 16
  • [10] In vitro and in vivo accuracy of full-arch digital implant impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Akulauskas, Mykolas
    Fehmer, Vincent
    Sailer, Irena
    Jegelevicius, Darius
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1444 - 1454