Brachytherapy dose inhomogeneity correction using I-125 seeds in the management of carcinomas of the nasopharynx

被引:0
|
作者
Sadeghi, KA
Bice, W
Prestidge, BR
机构
[1] UNIV TEXAS,HLTH SCI CTR,CANC THERAPY & RES CTR,SAN ANTONIO,TX 78229
[2] WILFORD HALL USAF MED CTR,SAN ANTONIO,TX 78229
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
引用
收藏
页码:C522 / C522
页数:1
相关论文
共 50 条
  • [31] TG43- and TG43U1-based dose calculations for I-125 brachytherapy seeds
    Fragoso, M
    Alves, C
    Lopes, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S26 - S26
  • [32] Treatment Planning Dosimetry Comparison Between Model 9011 I-125 ThinSeed and Model 6711 I-125 Seeds for Prostate Implant Brachytherapy
    Kudchadker, R.
    Du, W.
    Bruno, T.
    Pugh, T.
    Frank, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [33] Surface treatments of silver rods with enhanced iodide adsorption for I-125 brachytherapy seeds
    Lee, Jin Hee
    Choi, Kang Hyuk
    Yu, Kook Hyun
    APPLIED RADIATION AND ISOTOPES, 2014, 85 : 96 - 100
  • [34] Prostate permanent implant brachytherapy with BARC I-125 Ocu-Prosta seeds
    Palled, Siddanna R.
    Saminathan, Sathiyan
    Pasha, Tanvir
    Naveen, T.
    Ganesh, K. M.
    Lokesh, V.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (02) : 340 - 347
  • [35] Clinical Comparison of Point Source and Line Source Approximations for I-125 Brachytherapy Seeds
    Mensah-Brown, N.
    Enke, C.
    Deng, H.
    Zhou, S.
    Li, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [36] Positional and directional accuracy in the placement of I-125 seeds in permanent prostate brachytherapy implants
    Golshan, Maryam Afsari
    Spadinger, Ingrid
    Mahdavi, Sara
    MEDICAL PHYSICS, 2017, 44 (08) : 4381 - 4381
  • [37] A study of a pretreatment method to predict the number of I-125 seeds required for prostate brachytherapy
    Al-Qaisieh, Bashar
    Brearley, Elizabeth
    St Clair, Shaun
    Flynn, Anthony
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01): : 304 - 307
  • [38] Dynamics of implanted seeds in relation to resolution of edema in permanent I-125 prostate brachytherapy
    Beiki-Ardakani, A
    Crook, J
    Yeung, I
    RADIOTHERAPY AND ONCOLOGY, 2004, 72 : S18 - S19
  • [39] I-125 isodose patterns as predictors of inadequate prostate brachytherapy dose coverage
    Reed, D
    Wallner, K
    Cho, P
    Ford, E
    Merrick, G
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S123 - S124
  • [40] Realization of the Unit of Absorbed Dose to Water for I-125 Interstitial Brachytherapy Sources
    Schneider, T.
    Selbach, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3885 - 3885