Bi2S3/rGO Composite Based Electrochemical Sensor for Ascorbic Acid Detection

被引:36
|
作者
Qu, Chengling [1 ]
Li, He [1 ]
Zhou, Shuang [1 ]
Li, Guodong [2 ]
Wang, Cheng [1 ]
Snyders, Rony [3 ]
Bittencourt, Carla [3 ]
Li, Wenjiang [1 ]
机构
[1] Tianjin Univ Technol, Inst New Energy Mat & Low Carbon Technol, Sch Mat Sci & Engn, Tianjin 300384, Peoples R China
[2] Jilin Univ, Coll Chem, State Key Lab Inorgan Synth & Preparat Chem, Changchun 130012, Peoples R China
[3] Univ Mons, Plasma Surface Interact Chem ChIPS, Res Inst Mat Sci & Engn, 20 Pl Parc, B-7000 Mons, Belgium
基金
中国国家自然科学基金;
关键词
Bi2S3; reduced graphene oxide; ascorbic acid; electrochemical sensor; GRAPHENE OXIDE COMPOSITES; CARBON-PASTE ELECTRODE; ELECTROCATALYTIC OXIDATION; VOLTAMMETRIC DETERMINATION; HIGH-PERFORMANCE; FACILE SYNTHESIS; BISMUTH SULFIDE; URIC-ACID; DOPAMINE; NANOSHEETS;
D O I
10.3390/chemosensors9080190
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The engineering of an efficient electrochemical sensor based on a bismuth sulfide/reduced graphene oxide (Bi2S3/rGO) composite to detect ascorbic acid (AA) is reported. The Bi2S3 nanorods/ rGO composite was synthesized using a facile hydrothermal method. By varying the amount of graphene oxide (GO) added to the synthesis, the morphology and size of Bi2S3 nanorods anchored on the surface of rGO can be tuned. Compared to a bare glassy carbon electrode (GCE), the GCE modified with Bi2S3/rGO composite presented enhanced electrochemical performance, which was attributed to the optimal electron transport between the rGO support and the loaded Bi2S3 as well as to an increase in the number of active catalytic sites. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analysis of Bi2S3/rGO/GCE demonstrate that the active Bi2S3/rGO layer on GCE plays an important role in the electrochemical behavior of the sensor. In particular, the Bi2S3/rGO/GCE sensor shows a wide detecting range (5.0-1200 mu M), low detection limit (2.9 mu M), good sensitivity (268.8 mu A mM(-1) cm(-2)), and sufficient recovery values (97.1-101.6%) for the detection of ascorbic acid.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Ultrasensitive Electrochemical Sensor Based on β-Cyclodextrin–Polyaniline–Phosphomolybdic Acid Matrix for the Detection of Ascorbic Acid
    Xiaoxia Yu
    Qi Zhou
    Lihua Bi
    Russian Journal of Applied Chemistry, 2022, 95 : 1036 - 1047
  • [32] A Novel Co-MoS2/RGO-Based Highly Sensitive Sensor for Simultaneous Detection of Ascorbic Acid and Uric Acid
    Sharma, Seema
    Kumar, Prashant
    Samra, Kawaljeet Singh
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (11)
  • [33] Electrochemical detection and photodegradation of antihistamine promethazine hydrochloride in water using nanostructured Bi2S3 catalysts
    Ganesamurthi, Jaysiva
    Veerakumar, Pitchaimani
    Liu, Ting-Yu
    Juang, Ruey-Shin
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2024, 12 (02):
  • [34] Preparation and photocatalytic properties of Bi2S3/CNFs composite materials
    Wang, Mingfeng
    Shen, Jiuying
    Peng, Lei
    Liu, Runyu
    Liu, Xinzhong
    Xi, Beidou
    Jingxi Huagong/Fine Chemicals, 2021, 38 (09): : 1840 - 1847
  • [35] Molecularly Imprinted Photoelectrochemical Sensor Based on AgBiS2/Bi2S3 for Determination of Propoxur
    Shi, Xiao-Xue
    Li, Xiu-Qi
    Wei, Xiao-Ping
    Li, Jian-Ping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (03) : 396 - 404
  • [36] Enhanced dielectric properties of polypropylene based composite using Bi2S3 nanorod filler
    Dang, Yu
    Wang, Yao
    Deng, Yuan
    Li, Mao
    Zhang, Ye
    Zhang, Zhi-wei
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2011, 21 (03) : 216 - 220
  • [38] A stable electrochemical sensor for the detection of ascorbic acid based on Fe3O4/ZrO2 nano composite modified carbon paste electrode
    Bekele, Genet
    Tsegaye, Abebaw A.
    Taddesse, Abi M.
    Teju, Endale
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2024, 38 (05) : 1205 - 1223
  • [39] Highly selective and sensitive sensor based on an organic electrochemical transistor for the detection of ascorbic acid
    Zhang, Lijun
    Wang, Guiheng
    Wu, Di
    Xiong, Can
    Zheng, Lei
    Ding, Yunsheng
    Lu, Hongbo
    Zhang, Guobing
    Qiu, Longzhen
    BIOSENSORS & BIOELECTRONICS, 2018, 100 : 235 - 241
  • [40] Preparation of Nanoporous Gold-based Electrochemical Sensor for the Detection of Ascorbic Acid in Drinks
    Zhang Q.
    Cheng W.
    Zhang Y.
    Yang W.
    Yang Y.
    Tang X.
    Shipin Kexue/Food Science, 2021, 42 (20): : 274 - 279