Optimization of parameters of sampling and determination of reduced sulfur compounds using cryogenic capture and gas chromatography in tropical urban atmosphere

被引:20
|
作者
Campos, Vania P. [1 ]
Oliveira, Adriana S. [1 ]
Cruz, Licia P. S. [1 ]
Borges, Jomar [1 ]
Tavares, Tania M. [1 ]
机构
[1] Univ Fed Bahia, Dept Analyt Chem, Inst Chem, Salvador, BA, Brazil
关键词
Reduced sulfur compounds; Cryogenic capture; Gas chromatography; Atmosphere; HYDROGEN-SULFIDE; NATURAL SOURCES; COMPOUNDS RSC; EMISSIONS; WATER; H2S; REGION; BRAZIL; PARTS; AIR;
D O I
10.1016/j.microc.2010.04.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reduced sulfur compounds, RSCs (H(2)S, COS, CH(3)SH, CH(3)SCH(3), CS(2) and CH(3)S(2)CH(3)) play a role in global cycle and acid rain formation. At trace levels RSCs in air are difficult to collect, store and analyze because of their highly adsorptive and reactive properties. This work optimizes parameters of sampling and instrumental determination of RSCs for urban measurements. The method used is based on cryogenic sampling and gas chromatography provided with a cryofocusing trap and flame photometric detection. Greater sampling efficiency was obtained with liquid argon as freezing fluid and air flow rate of 150 mLmin(-1) for two hours. Best results have been obtained with preconcentration for 3 min and injection volume of 3 ml. For H(2)S, CH(3)SH and CH(3)S(2)CH(3) the method showed a precision of 89%, limit of detection of 0.10 mu g m(-3) and limit of quantification 03 mu g m(-3). For CH(3)SCH(3) and CS(2) the corresponding values were 89%, 0.15 mu g m(-3) and 0.5 mu g m(-3) and for COS were 75%, 0.18 mu g m(-3) and 0.8 mu g m(-3) respectively. Sampling efficiency varied between 70-80% for all the RSCs. Accuracy of H2S from field measurements obtained with parallel measurements using a continuous monitor varied between 88 and 98%. The optimized methodology proved to be suitable for field measurements in urban tropical atmospheres with different characteristics. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 38 条
  • [31] Headspace Liquid-Phase Microextraction Followed by Gas Chromatography-Mass Spectrometry for Determination of Furanic Compounds in Baby Foods and Method Optimization Using Response Surface Methodology
    Habibi, Hossein
    Mohammadi, Abdorreza
    Hoseini, Hedayat
    Mohammadi, Mehrdad
    Azadniya, Ebrahim
    FOOD ANALYTICAL METHODS, 2013, 6 (04) : 1056 - 1064
  • [32] Chemometric Study and Optimization of Headspace Solid-Phase Microextraction Parameters for the Determination of Multiclass Pesticide Residues in Processed Cocoa from Nigeria Using Gas Chromatography/Mass Spectrometry
    Abdulra'uf, Lukman Bola
    Tan, Guan Hoot
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 1007 - 1011
  • [34] Optimization of a methodology for simultaneous determination of twelve chlorophenols in environmental water samples using in situ derivatization and continuous sample drop flow microextraction combined with gas chromatography-electron-capture detection
    Karimaei, Mostafa
    Sharafi, Kiomars
    Moradi, Masoud
    Ghaffari, Hamid Reza
    Biglari, Hamed
    Arfaeinia, Hossein
    Fattahi, Nazir
    ANALYTICAL METHODS, 2017, 9 (19) : 2865 - 2872
  • [35] Efficient and sensitive quantification of polar tobacco volatile organic compounds by a micro thermal-assisted sampling device using reduced graphene oxide coupling with thermal desorption-gas chromatography/mass spectrometry
    Lai, Yanhua
    Han, Bing
    Wu, Jiahui
    Weng, Shouhui
    Chen, Senlin
    Wang, Junxia
    Wang, Yu
    Pan, Xiaowei
    Lin, Yun
    Tao, Hong
    Zhang, Zhuomin
    Li, Gongke
    ACTA CHROMATOGRAPHICA, 2024, 36 (03) : 263 - 272
  • [36] Screening method for the determination of 28 volatile organic compounds in indoor and outdoor air at environmental concentrations using dual-column capillary gas chromatography with tandem electron-capture-flame ionization detection
    Begerow, J
    Jermann, E
    Keles, T
    Koch, T
    Dunemann, L
    JOURNAL OF CHROMATOGRAPHY A, 1996, 749 (1-2) : 181 - 191
  • [37] Determination of short. chain chlorinated paraffins in ambient air using high. volume sampling combined with high resolution gas chromatography-electron capture negative ion-low resolution mass spectrometry
    Shi Leimeng
    Gao Yuan
    Hou Xiaohong
    Zhang Haijun
    Zhang Yichi
    Chen Jiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2016, 34 (02) : 202 - 208
  • [38] Optimization and validation of a head space solid-phase microextraction-arrow gas chromatography-mass spectrometry method using central composite design for determination of aroma compounds in Chinese liquor (Baijiu)
    Zhang, Xinyuan
    Wang, Chengcheng
    Wang, Lulu
    Chen, Shuang
    Xu, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1610