Dual-contrast decomposition of dual-energy CT using convolutional neural networks

被引:1
|
作者
Shapira, Nadav [1 ]
Cao, Wenchao [1 ]
Liu, Leening P. [1 ,2 ]
Leiner, Tim [3 ]
Smits, Maarten L. J. [3 ]
Noel, Peter B. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[3] Univ Utrecht, Med Ctr, Dept Radiol, Utrecht, Netherlands
关键词
Spectral CT; dual-energy CT (DECT); hepatic imaging; dual contrast protocols; deep learning; convolutional neural networks (CNN);
D O I
10.1117/12.2581333
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Liver lesion detection and characterization presents a longstanding challenge for radiologists. Since liver lesions are mainly characterized from information obtained at both arterial and portal venous circulatory phases, current hepatic Computed tomography (CT) protocols involve intravenous contrast injection and subsequent multiple CT acquisitions. Because detection of lesions by CT often requires further investigation with MRI, improved differentiation CT capabilities are highly desirable. Recently developed imaging protocols for spectral photon-counting CT enable simultaneous mapping of arterial and portal-venous enhancements by injecting two different contrast agents sequentially, allowing robust pixel-to-pixel spatial alignment between the different contrast phases with a reduction of radiation exposure. Here we propose a method that allows to quantitatively and reliably distinguish between two contrast agents in a single dual-energy CT (DECT) acquisition by taking advantage of the unique abilities of modern self-learning algorithms for non-linear mapping, feature extraction, and feature representation. For this purpose, we designed a U-net architecture convolutional neural network (CNN). To overcome training data requirements, we utilizing clinical DECT images to simulate dual-contrast spectral datasets. With the unique network architecture and training datasets, we demonstrate reliable dual-contrast quantifications from DECT. Our results demonstrate an ability to quantify densities of water, iodine and gadolinium, with root mean square errors of 0.2 g/ml, 1.32 mg/ml and 1.04 mg/ml, respectively. While observing some material-cross artifacts, our model demonstrated a high robustness to noise. With the rapid increase in DECT usage, our results pave the way for improved diagnostics and better patient outcome with available hardware implementations.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Calibration-Free Material Decomposition for Dual-Energy CT
    Zhao, W.
    Xing, L.
    Zhang, Q.
    Xiong, G.
    Min, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3396 - 3396
  • [32] Differentiation with the Dual-Energy CT
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (08): : 689 - 689
  • [33] Dual-Energy CT of the Pancreas
    Mastrodicasa, Domenico
    Delli Pizzi, Andrea
    Patel, Bhavik Natvar
    SEMINARS IN ULTRASOUND CT AND MRI, 2019, 40 (06) : 509 - 514
  • [34] Dual-Energy CT of the Lung
    Lu, Guang Ming
    Zhao, Yan'E
    Zhang, Long Jiang
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S40 - S53
  • [35] Nonuniqueness in dual-energy CT
    Levine, Zachary H.
    MEDICAL PHYSICS, 2017, 44 (09) : E202 - E206
  • [36] Dual-energy CT of the abdomen
    Desiree E. Morgan
    Abdominal Imaging, 2014, 39 : 108 - 134
  • [37] Dual-energy CT of the abdomen
    Morgan, Desiree E.
    ABDOMINAL IMAGING, 2014, 39 (01): : 108 - 134
  • [38] Dual-Energy CT of the Heart
    Vliegenthart, Rozemarijn
    Pelgrim, Gert Jan
    Ebersberger, Ullrich
    Rowe, Garrett W.
    Oudkerk, Matthijs
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S54 - S63
  • [39] A method for material decomposition in dual-energy contrast enhancement digital mammography
    Kahani, M.
    Kamali-asl, A.
    Ghadiri, H.
    Hashemi, S.
    MEASUREMENT, 2016, 88 : 87 - 95
  • [40] Dual-energy decomposition using a Kinestatic Charge Detector
    Endorf, RJ
    Schmithorst, VJ
    Kulatunga, S
    Spelic, DC
    Thomas, SR
    DiBianca, FA
    Rodriguez, C
    Zeman, HD
    Zhu, ZP
    Giakos, GC
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 695 - 706