A novel method for kinetic measurements of rare cell proliferation using Cellometer image-based cytometry

被引:10
|
作者
Chan, Leo L. [1 ]
Zhong, Xuemei [2 ]
Pirani, Alnoor [3 ]
Lin, Bo [3 ]
机构
[1] Nexcelom Biosci LLC, Dept Technol R&D, Lawrence, MA 01843 USA
[2] Boston Univ, Med Ctr, Dept Med, Hematol Oncol Sect, Boston, MA 02118 USA
[3] Nexcelom Biosci LLC, Dept Applicat, Lawrence, MA 01843 USA
关键词
Cell proliferation; Cellometer Vision; Image-based Cytometry (IBC); CFSE-labeling; B1 B cell; B2 B cell; FLOW-CYTOMETRY; B-CELLS; DIVISION; DIFFERENTIATION; GROWTH; DNA;
D O I
10.1016/j.jim.2012.01.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cell proliferation is an important assay for pharmaceutical and biomedical research to test the effects of a variety of treatments on cultured primary cells or cell lines. For immunological studies, the ability to perform rapid cell proliferation analysis allows the identification of potential biological reagents for inducing or inhibiting immune cell proliferation. Current cell proliferation analysis methods employ flow cytometry for fluorescence detection of CFSE-labeled cells. However, conventional flow cytometers require a considerable amount of cells per sample, which becomes an issue for kinetic measurements with rare cell population due to the lack of samples for flow cytometric analyses at multiple time points during proliferation period. Here we report the development of a novel cell proliferation kinetic detection method for low cell concentration samples using the new Cellometer Vision system. Since the Cellometer system requires only 20 mu l of sample, cell proliferation can be measured at multiple time points over the entire culturing period, whereas typically, flow cytometry is only performed at the end of the proliferation period. To validate the detection method, B1 and B2 B cells were treated with a B cell mitogen for 6 days, and proliferation was measured using Cellometer on day 1, 3, 5, and 6.10 demonstrate the capability of the system, B1 B cells were treated with a panel of TLR agonists (Pam3Cys, PolyIC, CLO97, and CpG) for 7 days, and proliferation was measured on day 2, 4, 6, and 7. Cellometer image-based cytometry (IBC) was able to obtain proliferation results on each day with the last time point comparable to flow cytometry. This novel method allows for kinetic measurements of the rare cell samples such as B1 B cell, which has the potential to revolutionize kinetic analysis of cell proliferation. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [41] A Novel Image-Based Malware Classification Model Using Deep Learning
    Jiang, Yongkang
    Li, Shenghong
    Wu, Yue
    Zou, Futai
    NEURAL INFORMATION PROCESSING (ICONIP 2019), PT II, 2019, 11954 : 150 - 161
  • [42] A novel phenotypic dissimilarity method for image-based high-throughput screens
    Zhang, Xian
    Boutros, Michael
    BMC BIOINFORMATICS, 2013, 14
  • [43] A novel phenotypic dissimilarity method for image-based high-throughput screens
    Xian Zhang
    Michael Boutros
    BMC Bioinformatics, 14
  • [44] Soiling Quantification Using an Image-Based Method: Effects of Imaging Conditions
    Yang, Mingda
    Ji, Jim
    Guo, Bing
    IEEE JOURNAL OF PHOTOVOLTAICS, 2020, 10 (06): : 1780 - 1787
  • [45] MR electrical properties imaging using a generalized image-based method
    Soullie, Paul
    Missoffe, Alexia
    Ambarki, Khalid
    Felblinger, Jacques
    Odille, Freddy
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (02) : 762 - 776
  • [46] Image-based grain partitioning using skeleton extension erosion method
    Wang, Yuzhu
    Sun, Shuyu
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2021, 205
  • [47] Image-Based Scam Detection Method Using an Attention Capsule Network
    Bian, Lingyu
    Zhang, Linlin
    Zhao, Kai
    Wang, Hao
    Gong, Shengjia
    IEEE ACCESS, 2021, 9 : 33654 - 33665
  • [48] A Novel 3-D Image-Based Morphological Method for Phenotypic Analysis
    Kristensen, Erika
    Parsons, Trish E.
    Hallgrimsson, Benedikt
    Boyd, Steven K.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (12) : 2826 - 2831
  • [49] Evaluation of regional bulbar redness using an image-based objective method
    Zhao, Wen-Juan
    Duan, Fang
    Li, Zhong-Ting
    Yang, Hua-Jun
    Huang, Qiang
    Wu, Kai-Li
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (01) : 71 - 76
  • [50] CONTROL MATERIALS TO IMPROVE COMPARABILITY BETWEEN FLUORESCENT IMAGE-BASED CELL VIABILITY MEASUREMENTS
    Pierce, L.
    Mohiuddin, M.
    Tona, A.
    Elliot, J.
    Sarkar, S.
    CYTOTHERAPY, 2024, 26 (06) : S120 - S120