A two-dimensional gas detector with individual readouts for neutron detection with a high spatial resolution and fast temporal response

被引:9
|
作者
Tanaka, H [1 ]
Nakamura, T [1 ]
Yamagishi, H [1 ]
Soyama, K [1 ]
Aizawa, K [1 ]
机构
[1] Neutron Sci Res Ctr, Japan Atom Energy Res Inst, Naka, Ibaraki 3191195, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2005年 / 76卷 / 09期
关键词
D O I
10.1063/1.2037967
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A gaseous neutron-imaging detector with individual signal readouts was developed for a high spatial resolution and a fast temporal response. The system comprises a multiwire head, a gas chamber with 541 channels, fast amplifier-shaper-discriminator boards, a logic circuit for position calculation and encoding, and a fast data-acquisition system. The developed prototype detector incorporating 40x40 channels exhibited a temporal response of similar to 100 ns (pulse width of the amplified signal) and a spatial resolution of 0.9 and 1.4 mm (full width at half maximum) in the x- and y-directions, respectively, with a gas pressure of 4.2-atm helium with 1.8-atm CF4. (c) 2005 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] On the determination of a detector response enhancement factor for flow modulated comprehensive two-dimensional gas chromatography
    Krupcik, Jan
    Majek, Pavel
    Gorovenko, Roman
    Spanik, Ivan
    Sandra, Pat
    Armstrong, Daniel W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1286 : 235 - 240
  • [32] Development of a Flat-Panel and Resistor-Type Photomultiplier Tube System for High Position-Resolution Two-Dimensional Neutron Detector
    Satoh, Setsuo
    PLASMA AND FUSION RESEARCH, 2018, 13
  • [33] Development of a flat-panel and resistor-type photomultiplier tube system for high position-resolution two-dimensional neutron detector
    Satoh S.
    Satoh, Setsuo (setsuo.satoh@kek.jp), 2018, Japan Society of Plasma Science and Nuclear Fusion Research (13)
  • [34] Development of two-dimensional multiwire-type neutron detector system with individual line readout and optical signal transmission
    Toh, K.
    Nakamura, T.
    Sakasai, K.
    Soyama, K.
    Hino, M.
    Kitaguchi, M.
    Yamagishi, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 726 : 169 - 174
  • [35] Fast two-dimensional detection for X-ray photon correlation spectroscopy using the PILATUS detector
    Westermeier, Fabian
    Autenrieth, Tina
    Gutt, Christian
    Leupold, Olaf
    Duri, Agnes
    Menzel, Andreas
    Johnson, Ian
    Broennimann, Christian
    Gruebel, Gerhard
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 687 - 689
  • [36] Enhancement of SNR and Spatial Resolution in φ-OTDR System by Using Two-Dimensional Edge Detection Method
    Zhu, Tao
    Xiao, Xianghui
    He, Qian
    Diao, Dongmei
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2013, 31 (17) : 2851 - 2856
  • [37] High-resolution separation of polychlorinated biphenyls by comprehensive two-dimensional gas chromatography
    Korytár, P
    Leonards, PEG
    de Boer, J
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2002, 958 (1-2) : 203 - 218
  • [38] High-resolution relaxation scheme for the two-dimensional Riemann problems in gas dynamics
    Seaïd, M
    NUMERICAL METHODS FOR PARTIAL DIFFERENTIAL EQUATIONS, 2006, 22 (02) : 397 - 413
  • [39] Solid state detector for high spatial resolution coupled to a single event acquisition system for slow neutron detection
    Casinini, F.
    Petrillo, C.
    Sacchetti, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 675 : 1 - 7
  • [40] Development of Two-dimensional Micro-pixel Gas Chamber Capable of Individual Line Readout for Neutron Measurement
    Toh, K.
    Yamagishi, H.
    Sakasai, K.
    Nakamura, T.
    Soyama, K.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 678 - 681