Corona-generated Space Charge Effects on Electric Field Distribution for an Indoor Corona Cage and a Monopolar Test Line

被引:33
|
作者
Bian, Xingming [1 ,2 ]
Yu, Deming [1 ,2 ]
Meng, Xiaobo [1 ,2 ]
MacAlpine, Mark [2 ]
Wang, Liming [2 ]
Guan, Zhicheng [1 ,2 ]
Yao, Wenjun [3 ]
Zhao, Shuzhen [3 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Grad Sch Shenzhen, Lab Adv Technol Elect Engn & Energy, Shenzhen 518055, Guangdong, Peoples R China
[3] N China Grid Co Ltd, Beijing Extra High Voltage Co, Beijing 102488, Peoples R China
基金
中国国家自然科学基金;
关键词
Positive corona; space charge; conductor; corona cage; test line; electric field; CONDUCTOR SURFACE CONDITIONS; VOLTAGE TRANSMISSION-LINES; HVDC TRANSMISSION; IONIZED FIELD; INTERFERENCE LEVEL; CURRENT-DENSITY; BIPOLAR CAGE; DISCHARGE; PREDETERMINATION; AVAILABILITY;
D O I
10.1109/TDEI.2011.6032849
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effects of corona-generated space charge on the resultant electric field near a conductor were determined both for a simulated test line and a corona cage, since both are used in predicting the corona behavior of EHV and UHV transmission lines. Programs were developed for the calculation of the potential, the electric field and the space charge distributions for a simulated test line and a corona cage. Algorithms based on the charge simulation and the finite-element methods were used to solve Poisson's equation; and the method of characteristics to solve the current continuity equation. The resultant electric field on the ground plane of the two configurations was measured with a rotating field-mill, and the results fitted well with the calculated data. It was found the electric field at the surface of the conductor increased linearly, for both experimental configurations, before the voltage reached the corona inception value; but was reduced once corona-generated space charge was produced. The space charge and density distribution in the corona cage differed greatly from that around the test line: the electric field at the surface of the conductor in the test line decreased faster with voltage than that in the corona cage, the relative difference increasing as V-app/V-on was raised. The difference reached an asymptote of about 16% when the applied voltage was about 25% above the corona inception level.
引用
收藏
页码:1767 / 1778
页数:12
相关论文
共 25 条
  • [1] A comparative study of space charge effects on corona current using an indoor corona cage and a monopolar test line
    Lekganyane, A. J.
    Ijumba, N. M.
    Britten, A. C.
    2007 IEEE POWER ENGINEERING SOCIETY CONFERENCE AND EXPOSITION IN AFRICA, VOLS 1 AND 2, 2007, : 422 - +
  • [2] Measurement of Corona-generated Space Charge Density Under DC Test Wire
    Wang, Lu
    Lu, Tiebing
    Ma, Wenzuo
    Qi, Xin
    Zou, Zhilong
    Sun, Shuai
    Bian, Xingming
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 911 - 914
  • [3] DC electric fields from corona-generated space charge near AC transmission lines
    Bracken, TD
    Senior, RS
    Bailey, WH
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 1692 - 1702
  • [4] Effects of humidity on variation of negative corona-generated space charge in rod to plane electrode
    Bian, Xingming
    He, Zichen
    Zhu, JunYu
    Pi, Xinan
    Wan, Shuwei
    Qi, Lei
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2869 - 2872
  • [5] CORONA-GENERATED SPACE-CHARGE ENVIRONMENT IN THE VICINITY OF HVDC TRANSMISSION-LINES
    MARUVADA, PS
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (02): : 125 - 130
  • [6] Distribution Characteristics of Corona Space Charge Generated from the ±1 100 kV UHVDC Overhead Transmission Line Under the Thundercloud Electric Field
    Chen S.
    He H.
    Zou Y.
    Yu J.
    Chen W.
    He J.
    He, Hengxin (hengxin_he@qq.com), 2018, Science Press (44): : 1367 - 1376
  • [7] The role of low air pressure in the variation of negative corona-generated space charge in a rod to plane electrode
    Bian XingMing
    Zhu JunYu
    Yang Wei
    Wan ShuWei
    Qi Lei
    Li XueBao
    Li HaiBing
    HIGH VOLTAGE, 2018, 3 (02): : 126 - 132
  • [8] Calculation of Ion Flow Field of Monopolar Transmission Line in Corona Cage Including the Effect of Wind
    Li, Zhenyu
    Zhao, Xuezeng
    ENERGIES, 2019, 12 (20)
  • [9] Measurement of Space Charge Distribution in a Corona Cage under Influence of different Atmospheric Conditions
    Djeumen, J. S.
    Walker, J. J.
    West, N. J.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [10] Electric field measurement on time domain generated by corona on insulators on distribution systems
    Mattos, MADF
    Biagioni, PH
    Bassi, W
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 328 - 330