Measurement of Corona-generated Space Charge Density Under DC Test Wire

被引:0
|
作者
Wang, Lu [1 ]
Lu, Tiebing [1 ]
Ma, Wenzuo [1 ]
Qi, Xin [1 ]
Zou, Zhilong [1 ]
Sun, Shuai [1 ]
Bian, Xingming [2 ,3 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Beijing Key Lab High Voltage, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, EMC, Beijing 102206, Peoples R China
关键词
space charge density; measuring apparatus; corona; HVDC; HVDC TRANSMISSION-LINES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Corona-generated space charge density is an important quantity that helps describe the electrical environment in the vicinity of High Voltage Direct Current (HVDC) transmission lines. This paper develops a device based on the ion counter method to measure space charge density under a DC test wire, which is used to simulate a HVDC transmission line. An experiment is carried out to analyze the various factors affecting the measurement. Another experiment, comparing the device with the indirect rotating field-mill method which is often used to measure space charge density at the ground level, is conducted to verify the feasibility and validity of the device and to calibrate its accuracy. Based on the device, the space charge distributions under the test wire are measured and analyzed.
引用
收藏
页码:911 / 914
页数:4
相关论文
共 50 条
  • [1] DC electric fields from corona-generated space charge near AC transmission lines
    Bracken, TD
    Senior, RS
    Bailey, WH
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 1692 - 1702
  • [2] Corona-generated Space Charge Effects on Electric Field Distribution for an Indoor Corona Cage and a Monopolar Test Line
    Bian, Xingming
    Yu, Deming
    Meng, Xiaobo
    MacAlpine, Mark
    Wang, Liming
    Guan, Zhicheng
    Yao, Wenjun
    Zhao, Shuzhen
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1767 - 1778
  • [3] Effects of humidity on variation of negative corona-generated space charge in rod to plane electrode
    Bian, Xingming
    He, Zichen
    Zhu, JunYu
    Pi, Xinan
    Wan, Shuwei
    Qi, Lei
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2869 - 2872
  • [4] CORONA-GENERATED SPACE-CHARGE ENVIRONMENT IN THE VICINITY OF HVDC TRANSMISSION-LINES
    MARUVADA, PS
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (02): : 125 - 130
  • [5] The role of low air pressure in the variation of negative corona-generated space charge in a rod to plane electrode
    Bian XingMing
    Zhu JunYu
    Yang Wei
    Wan ShuWei
    Qi Lei
    Li XueBao
    Li HaiBing
    HIGH VOLTAGE, 2018, 3 (02): : 126 - 132
  • [6] Space Charge Measurement Under DC and DC Periodic Waveform
    Romano, P.
    Imburgia, A.
    Candela, R.
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 293 - 296
  • [7] Experimental Study on Spectral Characteristics of Corona-Generated Audible Noise From a DC Conductor
    Li, Xuebao
    Cui, Xiang
    Lu, Tiebing
    Wang, Jing
    Hiziroglu, H. R.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (10) : 3690 - 3699
  • [8] Space Charge Distribution Measurement in Corona Discharged Filler Added Polyimide Films under DC Stresses
    Ota, Koichi
    Kumaoka, Kensuke
    Saiki, Takashi
    Miyake, Hiroaki
    Tanaka, Yasuhiro
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 159 - 162
  • [9] Statistical Characteristics and Stochastic Model of DC Corona-generated Sound Pressure Pulses from Single Corona Source
    Li, Xuebao
    Cui, Xiang
    Lu, Tiebing
    Wang, Zhenguo
    Zhang, Di
    Ma, Wenzuo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) : 2898 - 2906
  • [10] Measurement and analysis of time-domain characteristics of corona-generated radio interference from a single positive corona source
    Li, Xuebao
    Li, Dayong
    Chen, Bo
    Cui, Xiang
    Lu, Tiebing
    Li, Yinfei
    PHYSICS OF PLASMAS, 2018, 25 (04)