Scanning tunneling microscope with two-dimensional translator

被引:3
|
作者
Nichols, J. [1 ]
Ng, K. -W. [1 ]
机构
[1] Univ Kentucky, Dept Phys & Astron, Lexington, KY 40506 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2011年 / 82卷 / 01期
基金
美国国家科学基金会;
关键词
D O I
10.1063/1.3548832
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Since the invention of the scanning tunneling microscope (STM), it has been a powerful tool for probing the electronic properties of materials. Typically STM designs capable of obtaining resolution on the atomic scale are limited to a small area which can be probed. We have built an STM capable of coarse motion in two dimensions, the z- and x-directions which are, respectively, parallel and perpendicular to the tip. This allows us to image samples with very high resolution at sites separated by macroscopic distances. This device is a single unit with a compact design making it very stable. It can operate in either a horizontal or vertical configuration and at cryogenic temperatures. (C) 2011 American Institute of Physics. [doi:10.1063/1.3548832]
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Unisized two-dimensional platinum clusters on silicon(111)-7x7 surface observed with scanning tunneling microscope
    Yasumatsu, H
    Hayakawa, T
    Koizumi, S
    Kondow, T
    JOURNAL OF CHEMICAL PHYSICS, 2005, 123 (12):
  • [32] Two-dimensional tunneling in a SQUID
    Ivlev, B.
    Palomares-Baez, J. P.
    PHYSICAL REVIEW B, 2010, 82 (18):
  • [33] SCANNING TUNNELING MICROSCOPE
    PARK, SI
    QUATE, CF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (11): : 2010 - 2017
  • [34] THE SCANNING TUNNELING MICROSCOPE
    SALVAN, F
    RECHERCHE, 1986, 17 (181): : 1202 - &
  • [35] TWO-DIMENSIONAL RESONANT TUNNELING
    XUE, WG
    LEE, PA
    PHYSICAL REVIEW B, 1988, 38 (06): : 3913 - 3917
  • [36] Tunneling in two-dimensional QCD
    Olesen, Poul
    NUCLEAR PHYSICS B, 2006, 752 (1-2) : 197 - 205
  • [37] SCANNING TUNNELING MICROSCOPE
    UOSAKI, K
    DENKI KAGAKU, 1991, 59 (04): : 302 - 307
  • [38] THE SCANNING TUNNELING MICROSCOPE
    BINNIG, G
    ROHRER, H
    SCIENTIFIC AMERICAN, 1985, 253 (02) : 50 - &
  • [39] Two-dimensional weak-object transfer functions in the scanning harmonic microscope
    Gauderon, R
    Sheppard, CJR
    JOURNAL OF MODERN OPTICS, 2000, 47 (07) : 1195 - 1202
  • [40] Two-dimensional simulation and modeling in scanning electron microscope imaging and metrology research
    Postek, MT
    Vladár, AE
    Lowney, JR
    Keery, WJ
    SCANNING, 2002, 24 (04) : 179 - 185