The impact of diabetes on short-, intermediate- and long-term mortality following left ventricular assist device implantation

被引:7
|
作者
Kogan, Alexander [1 ,2 ]
Frogel, Jonathan [2 ,3 ]
Ram, Eilon [1 ,2 ]
Jamal, Tamer [1 ,2 ]
Peled-Potashnik, Yael [2 ,4 ]
Maor, Elad [2 ,4 ]
Grupper, Avishay [2 ,4 ]
Morgan, Avi [1 ,2 ]
Segev, Amit [2 ,4 ]
Raanani, Ehud [1 ,2 ]
Sternik, Leonid [1 ,2 ]
机构
[1] Sheba Med Ctr, Dept Cardiac Surg, IL-52621 Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Sch Med, Tel Aviv, Israel
[3] Sheba Med Ctr, Dept Anesthesiol, Tel Hashomer, Israel
[4] Sheba Med Ctr, Div Cardiol, Tel Hashomer, Israel
关键词
Left ventricular assist device; diabetes mellitus; mortality; HEART-FAILURE; OUTCOMES; SURVIVAL; MELLITUS; SOCIETY;
D O I
10.1093/ejcts/ezab575
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Type 2 diabetes mellitus (DM) is a frequent comorbidity among patients suffering from advanced heart failure necessitating a left ventricular assist device (LVAD) implant. The goal of this study was to evaluate the impact of type 2 DM on early and long-term outcomes of patients following an LVAD implant. METHODS: We performed an observational cohort study in a large tertiary care centre in Israel. All data of patients who underwent a continuous flow LVAD implant between 2006 and 2020 were extracted from our departmental database. Patients were divided into 2 groups: group I (patients without diabetes) and group II (patients with diabetes). We compared short-term (30-day and 3-month) mortality, intermediate-term (1- and 3-year) mortality and long-term (5 year) mortality between the 2 groups. RESULTS: The study population included 154 patients. Group I (patients without diabetes) comprised 88 patients and group II (patients with diabetes) comprised 66 patients. The mean follow-up duration was 38.2 +/- 30.3 months. Short- and intermediate-term mortality (30 days, 1 year and 3 years) was higher in the group with DM compared with the group without DM but did not reach any statistically significant difference: 16.1% vs 9.8% (P = 0.312), 24.2% vs 17.3% (P = 0.399) and 30.6% vs 21.9% (P = 0.127) respectively. Long-term 5-year mortality was significantly higher in the group with DM compared to the group without: 38.7% vs 24.4% (P = 0.038). Furthermore, predictors of long-term mortality included diabetes (hazard ratio 2.09, confidence interval 1.34-2.84, P = 0.004), as demonstrated by regression analysis. CONCLUSIONS: Patients with diabetes and those without diabetes have similar 30-day and short- and intermediate-term mortality rates. The mortality risk of diabetic patients begins to increase 3 years after an LVAD implant. Diabetes is an independent predictor of long-term, 5-year mortality after an LVAD implant.
引用
收藏
页码:1432 / 1437
页数:6
相关论文
共 50 条
  • [21] Readmission within 30 Days after Left Ventricular Assist Device Implantation Is Associated with Increased Long-Term Mortality
    Gupta, S.
    Roy, S.
    Cogswell, R.
    Thenappan, T.
    Liao, K.
    John, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S259 - S260
  • [22] Impact of Diabetes Mellitus on Mortality and In-Hospital Outcomes after Left Ventricular Assist Device Implantation
    Blumer, V.
    Ortiz, M.
    Hernandez, G.
    Chaparro, S.
    Vest, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S81 - S81
  • [23] Proactive Right Ventricular Assist Device Placement in Patients Undergoing Left Ventricular Assist Device Implantation Leads to Improved Short and Long Term Survival
    Crespo, R.
    Khan, N. A.
    Mudy, K.
    Bae, A.
    Samara, M.
    Eckman, P.
    Sun, B.
    Hryniewicz, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S366 - S366
  • [25] Long Term Neurocognitive Outcomes After Left Ventricular Assist Device Implantation
    Petrucci, R. J.
    Feitell, S. C.
    Gracely, E. J.
    Corvi, K. L.
    Rowe, T.
    Entwistle, J. W.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S197 - S197
  • [26] Impact of prealbumin on clinical outcomes following left ventricular assist device implantation
    Imamura, Teruhiko
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (06) : 1392 - 1392
  • [27] Short- and long-term mortality following hypnotic use
    Hedstrom, Anna Karin
    Hossjer, Ola
    Lagerros, Ylva Trolle
    Akerstedt, Torbjorn
    JOURNAL OF SLEEP RESEARCH, 2020, 29 (04)
  • [28] Short-, Intermediate-, and Long-Term Changes in Basophil Reactivity Induced by Venom Immunotherapy
    Rodriguez Trabado, Ana
    Camara Hijon, Carmen
    Ramos Cantarino, Alfonso
    Romero-Chala, Silvia
    Antonio Garcia-Trujillo, Jose
    Fernandez Pereira, Luis Miguel
    ALLERGY ASTHMA & IMMUNOLOGY RESEARCH, 2016, 8 (05) : 412 - 420
  • [29] Impact of Left Ventricular Size on Outcomes Following Heartmate 3 Left Ventricular Assist Device Implantation
    Nersesian, G.
    Jaiswal, A.
    Stein, J.
    Potapov, E.
    Baran, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S284 - S285
  • [30] The impact of time to catheter removal on short-, intermediate- and long-term urinary continence after radical prostatectomy
    Derya Tilki
    Felix Preisser
    Pierre Karakiewicz
    Shahrokh F. Shariat
    Markus Graefen
    Hartwig Huland
    Felix K. Chun
    Raisa S. Pompe
    World Journal of Urology, 2018, 36 : 1247 - 1253