Network and Field Analysis of Koch Snowflake Fractal Geometry Radiofrequency Coils for Sodium MRI

被引:0
|
作者
Nowikow, Cameron E. [1 ,2 ]
Polak, Paul [1 ,2 ]
Konyer, Norman B. [2 ]
Nikolova, Natalia K. [3 ]
Noseworthy, Michael D. [1 ,2 ,3 ,4 ]
机构
[1] McMaster Univ, Sch Biomed Engn, Hamilton, ON, Canada
[2] St Josephs Healthcare, Imaging Res Ctr, Hamilton, ON, Canada
[3] McMaster Univ, Elect & Comp Engn, Hamilton, ON, Canada
[4] McMaster Univ, Dept Radiol, Hamilton, ON, Canada
来源
FRONTIERS IN PHYSICS | 2021年 / 9卷
基金
加拿大自然科学与工程研究理事会;
关键词
radiofrequency coils; fractals; sodium-23; magnetic resonance imaging; koch; B1+mapping;
D O I
10.3389/fphy.2021.697104
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Sodium is one of the most abundant physiological cations and is a key element in many cellular processes. It has been shown that several pathologies, including degenerative brain disorders, cancers, and brain traumas, express sodium deviations from normal. Therefore, sodium magnetic resonance imaging (MRI) can prove to be valuable for physicians. However, sodium MRI has its limitations, the most significant being a signal-to-noise ratio (SNR) thousands of times lower than a typical proton MRI. Radiofrequency coils are the components of the MRI system directly responsible for signal generation and acquisition. This paper explores the intrinsic properties of a Koch snowflake fractal radiofrequency surface coil compared to that of a standard circular surface coil to investigate a fractal geometry's role in increasing SNR of sodium MRI scans. By first analyzing the network parameters of the two coils, it was found that the fractal coil had a better impedance match than the circular coil when loaded by various anatomical regions. Although this maximizes signal transfer between the coil and the system, this is at the expense of a lower Q, indicating greater signal loss between the tissue and coil. A second version of each coil was constructed to test the mutual inductance between the coils of the same geometry to see how they would behave as a phased array. It was found that the fractal coils were less sensitive to each other than the two circular coils, which would be beneficial when constructing and using phased array systems. The performance of each coil was then assessed for B-1 (+) field homogeneity and signal. A sodium phantom was imaged using a B-1 (+) mapping sequence, and a 3D radial acquisition was performed to determine SNR and image quality. The results indicated that the circular coil had a more homogeneous field and higher SNR. Overall while the circular coil proved to generate a higher signal-to-noise ratio than the fractal, the Koch coil showed higher versatility when in a multichannel network which could prove to be a benefit when designing, constructing, and using a phased array coil.
引用
收藏
页数:12
相关论文
共 26 条
  • [21] Generalized double-acquisition imaging for radiofrequency inhomogeneity mitigation in high-field MRI: Experimental proof and performance analysis
    Ferrand, Guillaume
    Luong, Michel
    Amadon, Alexis
    Cloos, Martijn A.
    Giacomini, Eric
    Darrasse, Luc
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 175 - 182
  • [22] Computational Analysis for the Combination of Inductive Coupled Wireless Coils and High Permittivity Materials to Improve B1 Field for Rhesus Monkey MRI
    Hernandez, Daniel
    Kim, Kyoung-Nam
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2019, 34 (09): : 1457 - 1460
  • [23] Computational analysis for the combination of inductive coupled wireless coils and high permittivity materials to improve B1 field for rhesus monkey MRI
    Hernandez, Daniel
    Kim, Kyoung-Nam
    Applied Computational Electromagnetics Society Journal, 2019, 34 (09): : 1457 - 1460
  • [24] Comparison of fluorescein sodium, 5-ALA, and intraoperative MRI for resection of high-grade gliomas: A systematic review and network meta-analysis
    Naik, Anant
    Smith, Emily J.
    Barreau, Ariana
    Nyaeme, Mark
    Cramer, Samuel W.
    Najafali, Daniel
    Krist, David T.
    Arnold, Paul M.
    Hassaneen, Wael
    JOURNAL OF CLINICAL NEUROSCIENCE, 2022, 98 : 240 - 247
  • [25] Comparing efficacy and safety between pulsed field ablation, cryoballoon ablation and high-power short duration radiofrequency ablation in atrial fibrillation: A systematic review and Network meta-analysis
    Deepan, Natee
    Sripusanapan, Adivitch
    Prasitlumkum, Narut
    Siranart, Noppachai
    Chokesuwattanaskul, Ronpichai
    Navaravong, Leenhapong
    Kewcharoen, Jakrin
    Pajareya, Patavee
    Tokavanich, Nithi
    CIRCULATION, 2024, 150
  • [26] Low viscosity dimethacrylate comonomer compositions [Bis-GMA and CH3Bis-GMA] for novel dental composites;: analysis of the network by stray-field MRI, solid-state NMR and DSC & FTIR
    Pereira, SG
    Nunes, TG
    Kalachandra, S
    BIOMATERIALS, 2002, 23 (18) : 3799 - 3806