Failure of locked coil wire rope of coal handling system

被引:3
|
作者
Parameswaran, P [1 ]
Raghunathan, VS
Hiremath, SC
Paknikar, KR
机构
[1] Indira Gandhi Ctr Atom Res, Mat Characterizat Grp, Kalpakkam 603102, Tamil Nadu, India
[2] Heavy Water Board, Bombay 400094, Maharashtra, India
[3] Heavy Water Plant, Manuguru 507116, Andhra Pradesh, India
关键词
rope failures; decarburisation; heat treatment; annealing; fatigue;
D O I
10.1016/S1350-6307(03)00019-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The outer Z-shaped wires of locked coil wire ropes used in coal transportation were found to fail frequently. A systematic metallographic investigation was carried out to understand the cause of failure. The wire was found to fail due to decarburised layers that form due to improper heat treatment procedure followed during production. The steps to avoid decarburisation and a comprehensive mechanical test were suggested to ascertain the life of the wire ropes. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:395 / 404
页数:10
相关论文
共 50 条
  • [31] TEXACO MASTO WIRE ROPE LUBRICATION SYSTEM
    NORGATE, R
    CIM BULLETIN, 1986, 79 (888): : 28 - 28
  • [32] MATERIALS HANDLING - WIRE ROPE SHOULD BE SELECTED AND CARED FOR AS WISELY AS ANY MACHINE
    RODES, TW
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1953, 45 (05): : A113 - A115
  • [33] The failure analysis of the drilling rig hoisting steel wire rope
    Peterka, Pavel
    Kresak, Jozef
    Vojtko, Marek
    Halek, Branislav
    Heinz, David
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2020, 22 (04): : 667 - 675
  • [34] An Analysis on the Engineering Failure of the Wire Rope Used in Surgical Instruments
    Xue, Yuhan
    Luo, Gangyin
    Liu, Xiang
    Xing, Yuan
    Hu, Bo
    Liu, Zhenglong
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (02) : 724 - 737
  • [35] An Analysis on the Engineering Failure of the Wire Rope Used in Surgical Instruments
    Yuhan Xue
    Gangyin Luo
    Xiang Liu
    Yuan Xing
    Bo Hu
    Zhenglong Liu
    Journal of Failure Analysis and Prevention, 2022, 22 : 724 - 737
  • [36] THE FATIGUE FAILURE OF LARGE DIAMETER 6 STRAND WIRE ROPE
    CASEY, NF
    LEE, WK
    INTERNATIONAL JOURNAL OF FATIGUE, 1989, 11 (02) : 78 - 84
  • [37] Study on corrosion law and mechanical properties of locked coil wire ropes
    Guo, Liulu
    Wang, Longxuan
    Chen, Zhihua
    Liu, Hongbo
    Yang, Zhengyan
    Zhang, Fan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
  • [38] Analysis of fatigue mechanism in locked coil wire ropes by means of fractography
    Woodtli, J
    Hellwig, C
    ADVANCES IN FRACTURE RESEARCH, VOLS 1-6, 1997, : 2587 - 2593
  • [39] Study of the lightning damage produced in a full-locked wire rope of an aerial cableway
    Fontanari, Vigilio
    Menapace, Cinzia
    Pedrotti, Ettore
    ENGINEERING FAILURE ANALYSIS, 2019, 103 : 530 - 539
  • [40] TESTING WIRE ROPE - MEASUREMENT SYSTEM AND EXPERIMENTAL STUDY
    MILBURN, DA
    SAMRAS, RK
    REPORT OF NRL PROGRESS, 1974, (JUN): : 52 - 53