Patient positioning and cup orientation during total hip arthroplasty: assessment of current UK practice

被引:9
|
作者
Rutherford, Megan [1 ]
O'Connor, John D. [1 ]
Hill, Janet C. [2 ]
Beverland, David E. [2 ]
Lennon, Alex B. [1 ]
Dunne, Nicholas J. [3 ,4 ,5 ,6 ,7 ]
机构
[1] Queens Univ Belfast, Sch Mech & Aerosp Engn, Belfast, Antrim, North Ireland
[2] Musgrave Pk Hosp, Primary Joint Unit, Belfast, Antrim, North Ireland
[3] Dublin City Univ, Sch Mech & Mfg Engn, Ctr Med Engn Res, Stokes Bldg,Collins Ave, Dublin 9, Ireland
[4] Queens Univ Belfast, Sch Pharm, Belfast, Antrim, North Ireland
[5] Trinity Coll Dublin, Trinity Biomed Sci Inst, Trinity Ctr Bioengn, Dublin, Ireland
[6] Trinity Coll Dublin, Dept Mech & Mfg Engn, Sch Engn, Dublin, Ireland
[7] Dublin City Univ, Sch Mech & Mfg Engn, Dublin, Ireland
关键词
Acetabular cup orientation; patient positioning; supports; total hip arthroplasty; TRANSVERSE ACETABULAR LIGAMENT; COMPONENT ORIENTATION; POLYETHYLENE WEAR; SAFE ZONE; DISLOCATION; REPLACEMENT; ACCURACY; PLACEMENT; MOVEMENT; RISK;
D O I
10.1177/1120700018760818
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Acetabular cup orientation during total hip arthroplasty (THA) remains a challenge. This is influenced by patient positioning during surgery and the method used to orientate the acetabular cup. The aim of this study was to assess current UK practice for patient positioning and cup orientation, particularly with respect to patient supports and techniques used to achieve target version and inclination. Methods: A literature review and pilot study were initially conducted to develop the questionnaire, which was completed by British Hip Society members (n = 183). As the majority of THA surgical procedures within the UK are performed with the patient in lateral decubitus, orthopaedic surgeons who operated with the patient in the supine position were excluded (n = 18); a further 6% were incomplete and also excluded (n = 11). Results: Of those who operated in lateral decubitus, 76.6% (n = 118/154) used the posterior approach. Only 31% (n = 47/154) considered their supports to be completely rigid. More than 35% (n = 55/154) were unhappy with the supports that they presently use. The most common methods for controlling operative inclination and version were a mechanical alignment guide (MAG; n = 78/154; 50.6%) and the transverse acetabular ligament (TAL; n = 82/154; 53.2%); 31.2% (48/154) used a freehand technique to control operative inclination. Conclusion: Limited studies have been conducted whereby patient supports have been analysed and key design principles outlined. With 35.7% of the orthopaedic surgeons surveyed having issues with their current supports, a greater awareness of essential characteristics for patient supports is required.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [21] The learning curve of robotic-arm assisted acetabular cup positioning during total hip arthroplasty
    Kayani, Babar
    Konan, Sujith
    Huq, Sumon S.
    Ibrahim, Mazin S.
    Ayuob, Atif
    Haddad, Fares S.
    [J]. HIP INTERNATIONAL, 2021, 31 (03) : 311 - 319
  • [22] Randomised controlled trial comparing two methods of acetabular cup positioning during total hip arthroplasty
    Vendittoli, P. -A.
    Ganapathi, M.
    Duval, N.
    Lavoie, P.
    Roy, A.
    Lavigne, M.
    [J]. HIP INTERNATIONAL, 2007, 17 (03) : 137 - 142
  • [23] A Novel Method for Accurate and Reproducible Functional Cup Positioning in Total Hip Arthroplasty
    Meftah, Morteza
    Yadav, Akhilesh
    Wong, Anthony C.
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (07): : 1200 - 1205
  • [24] The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty
    Archbold, H. A. P.
    Slomczykowski, M.
    Crone, M.
    Eckman, K.
    Jaramaz, B.
    Beverland, D. E.
    [J]. HIP INTERNATIONAL, 2008, 18 (01) : 1 - 6
  • [25] Danish survey of acetabular component positioning practice during primary total hip arthroplasty
    Cotong, Dana
    Troelsen, Anders
    Husted, Henrik
    Gromov, Kirill
    [J]. DANISH MEDICAL JOURNAL, 2017, 64 (04):
  • [26] Improving Acetabular Cup Orientation in Total Hip Arthroplasty by Using Smartphone Technology
    Peters, Frank M.
    Greeff, Richard
    Goldstein, Neal
    Frey, Chris T.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (07): : 1324 - 1330
  • [27] Improving Acetabular Cup Orientation in Total Hip Arthroplasty by Using Smartphone Technology
    Meermans, Geert
    Kats, Jan Jaap
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (07): : 1246 - 1246
  • [28] Changes in acetabular orientation during total hip arthroplasty
    Schloemann, D. T.
    Edelstein, A., I
    Barrack, R. L.
    [J]. BONE & JOINT JOURNAL, 2019, 101B (06): : 45 - 50
  • [29] radiographic assessment of the cup orientation after total hip arthroplasty: a literature review (vol 8, 130, 2020)
    Zhao, Jing-Xin
    Su, Xiu-Yun
    Zhao, Zhe
    Xiao, Ruo-Xiu
    Zhang, Li-Cheng
    Tang, Pei-Fu
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (10)
  • [30] Achieving Precise Cup Positioning in Direct Anterior Total Hip Arthroplasty: A Narrative Review
    Streck, Laura Elisa
    Boettner, Friedrich
    [J]. MEDICINA-LITHUANIA, 2023, 59 (02):