Volume reconstruction based on non-rigid registration

被引:0
|
作者
Bao, Xudong [1 ,3 ]
Xu, Danhua [1 ,3 ]
Toumoulin, Christine [2 ,3 ]
Luo, Limin [1 ,3 ]
机构
[1] Southeast Univ, Sch Comp Sci & Technol, Lab Image Sci & Technol, Nanjing 210096, Jiangsu, Peoples R China
[2] Univ Rennes 1, Lab Traitement Signal & Image, INSERM, U642, F-35000 Rennes, France
[3] CRIBs, Rennes, France
关键词
interpolation; non-rigid registration; level set;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Volume reconstruction is one of the key problems in 3D image rendering and analysis. Inter slice interpolation methods have been widely discussed in the literature and object-based algorithms have been shown to well behave. In this paper, we present a non-rigid registration based strategy to improve the volume reconstruction. A level set evolution technique is proposed to yield the deformation between adjacent slices. A modified bilinear interpolation method is then designed to generate propagating image. A multi-resolution scheme is applied to decrease the computation time and support large deformation. The resulting images show good results on regions enclosing different anatomic structures.
引用
收藏
页码:6536 / +
页数:3
相关论文
共 50 条
  • [21] Iterative Non-rigid Image Registration Based on Mobius Transformations
    Gerganov, Georgi V.
    Mitev, Krasimir K.
    Kawrakow, Iwan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2973 - 2975
  • [22] Non-rigid registration for cerebral DSA based on inverse stretching
    Key Laboratory for Precision and Non-traditional Machining, Dalian University of Technology, Dalian 116024, China
    Guangdianzi Jiguang, 2008, 8 (1137-1142):
  • [23] Feature Based Non-rigid Registration Using Quaternion Subdivision
    Ahmad, Fahad Hameed
    Natarajan, Sudha
    Jiang, Jimmy Liu
    MEDICAL BIOMETRICS, PROCEEDINGS, 2010, 6165 : 373 - +
  • [24] Vision based Tunnel Inspection using non-rigid Registration
    Badshah, Amir
    Ullah, Shan
    Shahzad, Danish
    TWELFTH INTERNATIONAL CONFERENCE ON QUALITY CONTROL BY ARTIFICIAL VISION, 2015, 9534
  • [25] TRACKING VOLUME CHANGE DURING IMRT TREATMENT USING NON-RIGID REGISTRATION
    Haga, A.
    Matsuura, T.
    Kida, S.
    Masutani, Y.
    Itoh, S.
    Saotome, N.
    Sakumi, A.
    Kotoku, J.
    Terahara, A.
    Nakagawa, K.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S444 - S444
  • [26] An Non-Rigid Online Volume Reconstruction Method Based on Energy Optimization of Dense Deformation Field
    Lin J.-H.
    Ma L.
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2021, 49 (05): : 936 - 943
  • [27] Coupled PDEs for non-rigid registration and segmentation
    Unal, G
    Slabaugh, G
    2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 1, PROCEEDINGS, 2005, : 168 - 175
  • [28] Optimized imaging using non-rigid registration
    Berkels, Benjamin
    Binev, Peter
    Blom, Douglas A.
    Dahmen, Wolfgang
    Sharpley, Robert C.
    Vogt, Thomas
    ULTRAMICROSCOPY, 2014, 138 : 46 - 56
  • [29] Improved non-rigid registration of prostate MRI
    d'Aische, AD
    De Craene, M
    Haker, S
    Weisenfeld, N
    Tempany, C
    Macq, B
    Warfield, SK
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 845 - 852
  • [30] Non-rigid registration under isometric deformations
    Huang, Qi-Xing
    Adams, Bart
    Wicke, Martin
    Guibas, Leonidas J.
    COMPUTER GRAPHICS FORUM, 2008, 27 (05) : 1449 - 1457