Magnetic Molecularly Imprinted Polymer (MMIP) Mediated Bacterial Esterase-Based Assay for Captan Detection in Milk

被引:2
|
作者
Kumar, Brijesh [1 ]
Yadav, Gulab Singh [1 ]
Kumar, Naresh [1 ]
Kumar, Amarjeet [1 ]
Raghu, H. V. [1 ]
机构
[1] ICAR Natl Dairy Res Inst, Dairy Microbiol Div, Natl Referral Ctr, Karnal 132001, India
关键词
Magnetic molecularly imprinted polymers; Captan pesticide; Enzyme Inhibition assay; Milk; ORGANOPHOSPHORUS PESTICIDE-RESIDUES; MULTIENZYME INHIBITION ASSAY; SOLID-PHASE EXTRACTION; INSECTICIDAL ORGANOPHOSPHATES; SELECTIVE DETERMINATION; BIOSENSOR; NANOPARTICLES; SAMPLES; WATER; ADSORPTION;
D O I
10.1007/s12161-021-02221-y
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In the current investigation, attempts were made to develop magnetic molecularly imprinted polymer (MMIP) conjugated with esterase inhibition-based detection method for selective extraction, concentration followed by detection of captan pesticide from the milk samples. The MMIP was synthesized based on iron magnetite (Fe3O4) encapsulated in the polymer of methacrylate (monomer) and ethyleneglycoldimethacrylate (monomer-cross-linker). It is the first time MMIP-based extraction method conjugated with the enzyme inhibition-based detection method. Different parameters like pH, temperature, and solvent for binding, washing, and elution were optimized. The MMIP was tested for binding with other related pesticides, i.e., maneb, atrazine, carbendazim, and thiram, and results showed an excellent selective binding performance for captan. The precision and accuracy of the extraction method were satisfactory for milk samples at the 20 ppm of captan spiking achieved a good recovery (%R) of 83.97 +/- 1.15% with a high relative standard deviation (RSD) of 1.93% (n= 5) for captan spiked skim milk sample and recovery (R%) of 72.8 +/- 2.11% with an RSD of 2.44% (n= 5) for captan spiked pasteurized milk sample. MMIPs were employed with developed esterase inhibition-based microtiter assay for pesticide detection and achieved an excellent limit of detection (LOD) up to 1 ppb. The extraction followed by detection of pesticide could be completed in 3.30-4.0 h. It would be a cost-effective option as compared to conventional techniques as it exploits the use of bacterial cells as an inexpensive source of enzyme, eliminating the need for expensive sample treatments as MMIP can be reused and has a long shelf-life.
引用
收藏
页码:1269 / 1285
页数:17
相关论文
共 50 条
  • [41] Selective Detection of Penicillin G Antibiotic in Milk by Molecularly Imprinted Polymer-Based Plasmonic SPR Sensor
    Bakhshpour, Monireh
    Goektuerk, Ilgim
    Bereli, Nilay
    Yilmaz, Fatma
    Denizli, Adil
    BIOMIMETICS, 2021, 6 (04)
  • [42] Dual Molecularly Imprinted Polymer-Based Plasmonic Immunosandwich Assay for the Specific and Sensitive Detection of Protein Biomarkers
    Xing, Rongrong
    Wen, Yanrong
    Dong, Yueru
    Wang, Yijia
    Zhang, Qi
    Liu, Zhen
    ANALYTICAL CHEMISTRY, 2019, 91 (15) : 9993 - 10000
  • [43] Molecularly imprinted polymer-based solid-phase extraction combined with molecularly imprinted polymer-based sensor for detection of uric acid
    Prasad, Bhim Bali
    Sharma, Piyush Sindhu
    Lakshmi, Dhana
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1173 (1-2) : 18 - 26
  • [44] Molecularly imprinted conducting polymer based electrochemical sensor for detection of atrazine
    Pardieu, Elodie
    Cheap, Helene
    Vedrine, Christophe
    Lazerges, Mathieu
    Lattach, Youssef
    Garnier, Francis
    Ramita, Samy
    Pernelle, Christine
    ANALYTICA CHIMICA ACTA, 2009, 649 (02) : 236 - 245
  • [45] Conductimetric sensor for atrazine detection based on molecularly imprinted polymer membranes
    Sergeyeva, TA
    Piletsky, SA
    Brovko, AA
    Slinchenko, EA
    Sergeeva, LM
    Panasyuk, TL
    El'skaya, AV
    ANALYST, 1999, 124 (03) : 331 - 334
  • [46] Surface molecularly imprinted polymer-based sensors for antibiotic detection
    Hasaneen, Noha
    Akhtarian, Shiva
    Pulicharla, Rama
    Brar, Satinder Kaur
    Rezai, Pouya
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 170
  • [47] Molecularly imprinted conducting polymer based sensor for Salmonella typhimurium detection
    Aparna
    Garg M.
    Vishwakarma N.
    Mizaikoff B.
    Singh S.
    Bioelectrochemistry, 2022, 147
  • [48] Acrylamide Based Molecularly Imprinted Polymer for Detection of m-Nitrophenol
    Kanai, Tapan
    Sanskriti, C.
    Vislawath, Prakash
    Samui, Asit Baran
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (04) : 3054 - 3061
  • [49] Molecularly Imprinted Polymer-Based Sensor for Electrochemical Detection of Cortisol
    Yulianti, Elly Septia
    Rahman, Siti Fauziyah
    Whulanza, Yudan
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [50] Molecularly imprinted polymer-based sensor for electrochemical detection of erythromycin
    Ayankojo, Akinrinade George
    Reut, Jekaterina
    Ciocan, Valeriu
    Opik, Andres
    Syritski, Vitali
    TALANTA, 2020, 209