Aspects of oligonucleotide and peptide sequencing with MALDI and electrospray mass spectrometry

被引:18
|
作者
Owens, DR
Bothner, B
Phung, Q
Harris, K
Siuzdak, G
机构
[1] Scripps Res Inst, Dept Chem, La Jolla, CA 92037 USA
[2] Scripps Res Inst, Dept Mol Biol, La Jolla, CA 92037 USA
关键词
D O I
10.1016/S0968-0896(98)00098-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Biopolymer sequencing with mass spectrometry has become increasingly important and accessible with the development of matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI). Here we examine the use of sequential digestion for the rapid identification of proteolytic fragments, in turn highlighting the general utility of enzymatic MALDI ladder sequencing and ESI tandem mass spectrometry. Analyses were performed on oligonucleotides ranging in size from 2 to 50 residues, on peptides ranging in size from 7 to 44 residues and on viral coat proteins. MALDI ladder sequencing using exonuclease digestion generated a uniform distribution of ions and provided complete sequence information on the oligonucleotides 2-30 nucleic acid residues long. Only partial sequence information was obtained on the longer oligonucleotides. C-terminal peptide ladder sequencing typically provided information from 4 to 7 amino acids into the peptide. Sequential digestion, or endoprotease followed by exoprotease exposure, was also successfully applied to a trypsin digest of viral proteins. Analysis of ladder sequenced peptides by LCMS generated less information than in the MALDI-MS analysis and ESI-MS2 normally provided partial sequence information on both the small oligonucleotides and peptides. In general, MALDI ladder sequencing offered information on a broader mass range of biopolymers than ESI-MS2 and was relatively straightforward to interpret, especially for oligonucleotides. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1547 / 1554
页数:8
相关论文
共 50 条
  • [21] Electrospray and MALDI mass spectrometry in the identification of spermicides in criminal investigations
    Hollenbeck, TPE
    Siuzdak, G
    Blackledge, RD
    JOURNAL OF FORENSIC SCIENCES, 1999, 44 (04) : 783 - 788
  • [22] Oxidation artifacts in the electrospray mass spectrometry of Aβ peptide
    Chen, Maolian
    Cook, Kelsey D.
    ANALYTICAL CHEMISTRY, 2007, 79 (05) : 2031 - 2036
  • [23] CONFIRMATION OF OLIGONUCLEOTIDE SYNTHESIS BY ELECTROSPRAY IONIZATION-MASS SPECTROMETRY
    REDDY, DM
    IDEN, CR
    AMERICAN LABORATORY, 1995, 27 (09) : 15 - +
  • [25] Efficient peptide ladder sequencing by MALDI-TOF mass spectrometry using allyl isothiocyanate
    Gu, QM
    Prestwich, GD
    JOURNAL OF PEPTIDE RESEARCH, 1997, 49 (06): : 484 - 491
  • [26] Free Radical Initiated Peptide Sequencing Using MALDI-TOF/TOF Mass Spectrometry
    Song, Insu
    Lee, Jae-ung
    Baek, Jaehyeon
    Cha, Sangwon
    Han, Sang Yun
    Oh, Han Bin
    MASS SPECTROMETRY LETTERS, 2018, 9 (02) : 56 - 60
  • [27] Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
    El-Aneed, Anas
    Cohen, Aljandro
    Banoub, Joseph
    APPLIED SPECTROSCOPY REVIEWS, 2009, 44 (03) : 210 - 230
  • [28] PEPTIDE SEQUENCING BY MASS-SPECTROMETRY
    STULTS, JT
    METHODS OF BIOCHEMICAL ANALYSIS, 1990, 34 : 145 - 201
  • [29] Accurate peptide sequencing by mass spectrometry
    Takao, T
    Mo, W
    Fernandez-de-Cossio, J
    Gonzalez, J
    Besada, V
    Padron, G
    Shimonishi, Y
    PEPTIDE SCIENCE - PRESENT AND FUTURE, 1999, : 146 - 151
  • [30] Effects of tryptic peptide esterification in MALDI mass spectrometry
    Kim, TY
    Brun, YV
    Reilly, JP
    ANALYTICAL CHEMISTRY, 2005, 77 (13) : 4185 - 4193