P wave signal averaged ECG and chemoreflexsensitivity in paroxysmal atrial fibrillation

被引:13
|
作者
Budeus, M
Hennersdorf, M
Wieneke, H
Sack, S
Erbel, R
Perings, C
机构
[1] Univ Duisburg, W German Heart Ctr, Dept Cardiol, D-45122 Essen, Germany
[2] Univ Dusseldorf, Med Clin & Policlin B, Dept Cardiol Pneumol & Angiol, Dusseldorf, Germany
[3] Ruhr Univ Bochum, Univ Hosp Herne, Dept Cardiol & Angiol, D-4690 Herne, Germany
关键词
P wave signal averaged ECG; paroxysmal atrial fibrillation; chemoreflexsensitivity; autonomic nervous system; neurovegetative imbalance;
D O I
10.1016/j.ijcard.2004.12.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Detailed analysis of the QRS-complex and autonomic dysfunction can identify patients at risk to suffer from ventricular arrhythmias. To determine whether patients at risk for paroxysmal atrial fibrillation (PAF) could be identified while in sinus rhythm, a P wave triggered signal averaged ECG and an analysis of the autonomic function by chemoreflexsensitivity (CHRS) were examined. The ratio between the difference of RR intervals in the ECG and the venous partial pressure of oxygen before and after 5-min oxygen inhalation was measured for the determination of CHRS. We examined 224 patients (group A) who suffered from PAF, 250 patients (group 13) without arrhythmic history and 30 young volunteers (group C). The filtered P wave duration (FPD) was significantly longer in group A than in group B (140.9 +/- 21.0 vs. 118.2 +/- 9.4 ms,p < 0.0001) or C (105.2 +/- 14.1 ms, p < 0.0001) while the root mean square voltage of the last 20 ms of the P wave (RMS 20) was significantly lower in group A than in group B (2.68 +/- 1.12 vs. 4.06 +/- 1.57 mu V, p < 0.0001) or C (3.97 +/- 1.36 mu V, p < 0.0001). Atrial late potentials (ALP) were defined as a FPD > 120 ms and a RMS 20 <= 3.5 mu V. ALP could identify patients of group A with a specificity of 78% and a sensitivity of 83%. Patients with PAF (2.32 +/- 1.15 ms/mm Hg) showed a significantly lower CHRS than group B (4.14 +/- 1.58 ms/mm Hg, p < 0.0001) or group C (4.98 +/- 1.51 ms/mm Hg, p < 0.0001). The sensitivity for the presence of atrial fibrillation was 71% for a CHRS below 3.0 ms/mm Hg with a specificity of 70%. A combination of both methods showed a specificity of 85% and a sensitivity of 65% when ALP and pathological CHRS were present. The results of our study suggest that risk of atrial fibrillation could be detected by P wave signal averaged ECG and CHRS. An analysis of CHRS seems to be an appropriate method to demonstrate a neurovegetative imbalance, which might be one possible trigger mechanism. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [21] P wave signal averaged ECG criteria in predicting early recurrence of atrial fibrillation: A prospective study
    Guo, XH
    Gallagher, MM
    Harries, M
    Camm, AJ
    CIRCULATION, 2000, 102 (18) : 828 - 828
  • [22] Spectrotemporal analysis of the P Wave signal-averaged ECG in patients with atrial fibrillation and control subjects
    Zaliunas, R
    Slapikas, R
    Zabiela, P
    Ablonskyte, R
    Bechtold, H
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 449 - 453
  • [23] Prediction of the recurrence of atrial fibrillation after successful cardioversion with P wave signal-averaged ECG
    Budeus, M
    Hennersdorf, M
    Perings, C
    Wieneke, H
    Erbel, R
    Sack, S
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2005, 10 (04) : 414 - 419
  • [24] Signal-averaged P-wave abnormalities and atrial size in patients with and without idiopathic paroxysmal atrial fibrillation
    Ishimoto, N
    Ito, M
    Kinoshita, M
    AMERICAN HEART JOURNAL, 2000, 139 (04) : 684 - 689
  • [25] P-wave signal-averaged ECG in normal population and in patients with converted atrial fibrillation
    Militaru, Constantin
    Donoiu, Ionut
    Istratoaie, Octavian
    Ionescu, Dan-Dominic
    CIRCULATION, 2012, 125 (19) : E837 - E837
  • [26] P wave signal averaged ECG criteria in predicting early recurrence of atrial fibrillation: A prospective study
    Guo, XH
    Yap, YG
    Gallagher, MM
    Luddington, L
    Camm, AJ
    Malik, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 131A - 131A
  • [27] P wave signal-averaged ECG predicts the recurrence of paroxysmal atrial fibrillation in patients with accessory pathways who underwent successful catheter ablation
    Hiraki, T
    Ohga, M
    Kubara, I
    Yoshida, T
    Kanahara, M
    CIRCULATION, 1997, 96 (08) : 3645 - 3645
  • [28] Dispersion of signal-averaged P wave duration on precordial body surface in patients with paroxysmal atrial fibrillation
    Yamada, T
    Fukunami, M
    Shimonagata, T
    Kumagai, K
    Sanada, S
    Ogita, H
    Asano, Y
    Hori, M
    Hoki, N
    EUROPEAN HEART JOURNAL, 1999, 20 (03) : 211 - 220
  • [29] Prediction of atrial fibrillation by signal-averaged P wave ECG; long-term prospective study
    Kang, T. S.
    Kwon, H. M.
    Yoon, Y. W.
    Lee, S. J.
    Kwon, S. W.
    Park, J. K.
    Yoon, S. J.
    Hong, B. K.
    EUROPEAN HEART JOURNAL, 2005, 26 : 376 - 376
  • [30] PREDICTION OF TRANSITION FROM PAROXYSMAL ATRIAL-FIBRILLATION TO CHRONIC ATRIAL-FIBRILLATION BY P-WAVE-TRIGGERED SIGNAL-AVERAGED ELECTROCARDIOGRAM
    ABE, Y
    FUKUNAMI, M
    OHMORI, M
    KUMAGAI, K
    YAMADA, T
    NISHIKAWA, N
    HOKI, N
    CIRCULATION, 1993, 88 (04) : 312 - 312