Comparison of in-hospital and long-term outcomes between a Cypher stent and a Taxus stent in Chinese diabetic patients with coronary artery disease

被引:7
|
作者
Yang Yue-jin [1 ]
Xu Bo [1 ]
Kang Sheng [1 ]
Pei Wei-dong [1 ]
Chen Ji-lin [1 ]
Qiao Shu-bin [1 ]
Qin Xue-wen [1 ]
Yao Min [1 ]
Chen Jue [1 ]
Wu Yong-jian [1 ]
Liu Hai-bo [1 ]
You Shi-jie [1 ]
Li Jian-jun [1 ]
Dai Jun [1 ]
Gao Run-lin [1 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll, Fuwai Hosp, Cardiovasc Inst,Coronary Heart Dis Ctr,Dept Cardi, Beijing 100037, Peoples R China
关键词
diabetes; percutaneous coronary intervention; stent; outcomes;
D O I
10.1097/00029330-200711010-00003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The sirolimus and paclitaxel distribution patterns and tissue residence time may be modified in atherosclerotic lesions for patients with diabetes, and the biological mechanisms of action for these agents differ significantly. Previous clinical trials have yielded discrepant results of major adverse cardiac events and restenosis between a sirolimus-eluting stent and a paclitaxel-eluting stent in coronary artery disease. Therefore, this study was conduced to compare in-hospital and long-term clinical outcomes between patients receiving sirolimus-eluting stent (Cypher or Cypher Select stent) and paclitaxel-eluting stent (Taxus Express stent) after percutaneous intervention (PCI) in Chinese patients with diabetes. Methods One hundred and sixty-four consecutive diabetic patients underwent PCI in Fuwai Hospital from April 2004 to December 2004. Of them, 101 patients received Cypher or Cypher Select stents (Cypher group, 145 stents) and 63 patients received Taxus Express stents (Taxus group, 129 stents). Repeat coronary angiography was performed at 6-month and clinical outcomes were evaluated at 1- and 3-year follow-up. Stent thrombosis was classified according to Academic Research Consortium (ARC). Results The two groups did not differ significantly with respect to cardiac death, recurrent myocardial infarction (re-MI), target vessel revascularization (TVR) and occurrence of major adverse cardiac events (MACE). And the MACE-free cumulative survival at 1- and 3-year follow-up and early, late and very late thrombosis rates were also similar in the two groups (all P > 0.05). There was a trend favoring PES over SES with regard to reducing cardiac death (0 vs 2.0%, P=0.524), re-MI (0 vs 2.0%, P=0.524), the composite of the cardiac death and re-MI (0 vs 4.0%, P=0.299) and very late thrombosis (0 vs 3.0%, P=0.295) between 1-year and 3-year follow-up. Conclusion The study indicates that PCI with either Cypher or Taxus stents is associated with similar efficacy and safety in the small population of Chinese diabetic patients during long-term follow-up.
引用
收藏
页码:1868 / 1873
页数:6
相关论文
共 50 条
  • [41] Long-term survival of patients after coronary artery bypass graft surgery: Comparison of the pre-stent and post-stent eras
    Gao, Guangqiang
    Wu, YingXing
    Grunkemeier, Gary L.
    Furnary, Anthony P.
    Starr, Albert
    ANNALS OF THORACIC SURGERY, 2006, 82 (03): : 806 - 811
  • [42] Relationship between hyperhomocysteine and long-term outcome of coronary artery disease patients after drug-eluting stent implantation
    鄢高亮
    ChinaMedicalAbstracts(InternalMedicine), 2016, 33 (01) : 25 - 26
  • [43] Long-Term Outcomes of the Viabahn Stent in the Treatment of In-Stent Restenosis in the Superficial Femoral Artery
    Gorgani, Farzan
    Telis, Anatoliy
    Narakathu, Niju
    LaBarbera, Matthew
    Babaev, Anvar
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (12): : 670 - 674
  • [44] Periprocedural and Long-Term Outcomes of Stent Implantation for De Novo Subclavian Artery Disease
    Onishi, Hirokazu
    Naganuma, Toru
    Hozawa, Koji
    Sato, Tomohiko
    Ishiguro, Hisaaki
    Tahara, Satoko
    Kurita, Naoyuki
    Nakamura, Shotaro
    Nakamura, Sunao
    VASCULAR AND ENDOVASCULAR SURGERY, 2019, 53 (04) : 284 - 291
  • [45] Long-Term Outcomes of Intraoperative Pulmonary Artery Stent Placement for Congenital Heart Disease
    Angtuaco, Michael J.
    Sachdeva, Ritu
    Jaquiss, Robert D. B.
    Morrow, W. Robert
    Gossett, Jeffrey M.
    Fontenot, Eudice
    Seib, Paul M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (03) : 395 - 399
  • [46] Comparison of efficacy and safety between sirolimus-eluting stent (Cypher™) and paclitaxel-eluting stent (TAXUS™) on the outcome of patients with small coronary arteries:: Multicenter registry in Asia
    Nakamura, S
    Bae, JH
    Cahyadi, YH
    Udayachalerm, W
    Tresukosol, D
    Tansuphaswadikul, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 169H - 169H
  • [47] Comparison of efficacy and safety between Sirolimus-eluting stent (Cypher) and Paclitaxel-eluting stent (TAXUS) on the outcome of patients with small coronary arteries: multicenter registry in Asia
    Nakamura, S.
    Bae, J. H.
    Cahyadi, Y. H.
    Udayachalerm, W.
    Tresukosol, D.
    Tansuphaswadikul, S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 92 - 92
  • [48] Short- and Long-Term Outcomes of Coronary Artery Bypass Grafting or Drug-Eluting Stent Implantation for Multivessel Coronary Artery Disease in Patients With Chronic Kidney Disease
    Ashrith, Guha
    Lee, Vei-Vei
    Elayda, MacArthur A.
    Reul, Ross M.
    Wilson, James M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03): : 348 - 353
  • [49] Long-term outcomes after coronary bare-metal-stent and drug-eluting-stent implantations: a 'real-world' comparison among patients with diabetes with diffuse small vessel coronary artery disease
    Koh, Angela S.
    Chia, Stanley
    Choi, Lok Man
    Sim, Ling Ling
    Chua, Terrance S. J.
    Koh, Tian Hai
    Tan, Jack W. C.
    CORONARY ARTERY DISEASE, 2011, 22 (02) : 96 - 99
  • [50] Clinical Impact of Angiographic Restenosis After Bare-Metal Stent Implantation on Long-Term Outcomes in Patients With Coronary Artery Disease
    Ogita, Manabu
    Miyauchi, Katsumi
    Kurata, Takeshi
    Yokoyama, Ken
    Dohi, Tomotaka
    Tuboi, Shuta
    Miyazaki, Tadashi
    Nishino, Akihisa
    Yokoyama, Takayuki
    Daida, Hiroyuki
    CIRCULATION JOURNAL, 2011, 75 (11) : 2566 - 2572