The influence of flow, vessel diameter, and non-Newtonian blood viscosity on the wall shear stress in a carotid bifurcation model for unsteady flow

被引:56
|
作者
Box, FMA
van der Geest, RJ
Rutten, MCM
Reiber, JHC
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, NL-2300 RC Leiden, Netherlands
[2] Eindhoven Univ Technol, Dept Biomed Engn, Eindhoven, Netherlands
关键词
wall shear stress; vessel diameter; blood viscosity; flow rate; MRI; finite element method;
D O I
10.1097/01.rli.0000160550.95547.22
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The atherosclerotic process in arteries is correlated with the local wall shear stress (WSS). Plaque development particularly occurs in regions with recirculation (ie, where the WSS oscillates). We investigated the effects of non-Newtonian blood viscosity, variations in flow rate, and vessel diameter on wall phenomena in a carotid bifurcation model. Materials and Methods: The flow through a model of a carotid artery bifurcation was simulated by means of the finite element method. The whole-blood viscosity is a function of shear rate, and was modeled by the Carreau-Yasuda (CY) model. Flow rate and vessel morphology were assessed with magnetic resonance imaging. Flow rate, blood viscosity, and hematocrit levels (Hct) were measured in 49 healthy volunteers. We propose an adaptation of the CY model so that differences in Hct can be incorporated; furthermore, plasma viscosity was varied in the CY model. Results: The data from our model indicate that flow increases have a larger effect on the WSS than predicted with a simple paraboloid model. Hct had more influence on the WSS when the plasma viscosity was low. Low plasma viscosity was associated with a low WSS, which implies a contradiction, because both high WSS and low plasma viscosity are thought to be indicators for a healthy system. Maximum WSS oscillations were found at the edges of the recirculation region. Conclusions: Flow and diameter changes have significant influence on wall shear stress values; the same is true for the viscosity, but to a lesser extent.
引用
收藏
页码:277 / 294
页数:18
相关论文
共 50 条
  • [21] Computational simulation of non-Newtonian blood flow in carotid bifurcation for investigating the various rheological blood models
    Jahanyfard, E.
    Firoozabadi, B.
    Chegini, A. Goodarzvand
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 2: BIOMEDICAL AND BIOTECHNOLOGY ENGINEERING, 2008, : 263 - 270
  • [22] The influence of the non-Newtonian properties of blood on the flow in large arteries: Unsteady flow in a 90°curved tube
    Department of Mechanical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, Netherlands
    J. Biomech., 7 (705-713):
  • [23] The influence of the non-Newtonian properties of blood on the flow in large arteries:: unsteady flow in a 90° curved tube
    Gijsen, FJH
    Allanic, E
    van de Vosse, FN
    Janssen, JD
    JOURNAL OF BIOMECHANICS, 1999, 32 (07) : 705 - 713
  • [24] Numerical simulation of the blood flow. consequence of the non-Newtonian behavior, application to the carotid bifurcation
    Bachelet, C
    Dantan, PH
    Flaud, P
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 167 - 167
  • [25] MOVEMENT OF A SPHERE ON A FLAT WALL IN NON-NEWTONIAN SHEAR FLOW
    Ignatenko, Yaroslav
    Bocharov, Oleg
    May, Roland
    PROCEEDINGS OF THE ASME 36TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2017, VOL 8, 2017,
  • [26] WALL REGION IN TURBULENT SHEAR FLOW OF NON-NEWTONIAN FLUIDS
    TENNEKES, H
    PHYSICS OF FLUIDS, 1966, 9 (05) : 872 - &
  • [27] Study of the effect of stenosis severity and non-Newtonian viscosity on multidirectional wall shear stress and flow disturbances in the carotid artery using particle image velocimetry
    DiCarlo, Amanda L.
    Holdsworth, David W.
    Poepping, Tamie L.
    MEDICAL ENGINEERING & PHYSICS, 2019, 65 : 8 - 23
  • [28] Influence of non-Newtonian blood flow models on drug deposition in the arterial wall
    Gudino, Elias
    Oishi, Cassio M.
    Sequeira, Adelia
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2019, 274
  • [29] Influence of Arterial Vessel Diameter and Blood Viscosity on PTT in Pulsatile Flow Model
    Zienkiewicz, Aleksandra
    Vihriala, Erkki
    Myllyla, Teemu
    DIGITAL HEALTH AND WIRELESS SOLUTIONS, PT II, NCDHWS 2024, 2024, 2084 : 186 - 199
  • [30] Influence of non-Newtonian behavior of blood on flow in an elastic artery model
    Dutta, A
    Tarbell, JM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (01): : 111 - 119