Flow Cytometry Panel-Reactive Antibody Screening of Anti-HLA Antibodies in the Waiting List Significantly Reduces the Occurrence of Acute Rejection After Kidney Transplantation

被引:1
|
作者
Dedinska, I. [1 ,2 ,3 ]
Mackova, N. [4 ]
Machalekova, K. [5 ]
Miklusica, J. [1 ,2 ,3 ]
Palkoci, B. [1 ,2 ,3 ]
Flalova, J. [1 ,2 ,3 ]
Cellar, M. [6 ]
Galajda, P. [3 ,7 ]
Mokan, M. [3 ,7 ]
机构
[1] Univ Hosp Martin, Surgery Clin, Kollarova 2, Martin 03601, Slovakia
[2] Univ Hosp Martin, Transplant Ctr, Kollarova 2, Martin 03601, Slovakia
[3] Comenius Univ, Jessenius Fac Med, Martin, Slovakia
[4] Martinske Ctr Immunol, Martin, Slovakia
[5] BB Biocyt, Banska Bystrica, Slovakia
[6] Slovak Med Univ, FD Roosevelts Fac Hosp Banska Bystrica, Internal Clin 2, Dept Transplant Nephrol, Banska Bystrica, Slovakia
[7] Univ Hosp Martin, Clin Internal Med 1, Martin, Slovakia
关键词
GRAFT FAILURE; CLASS-I; IMMUNOSUPPRESSION; RECIPIENTS; ASSAY; RISK;
D O I
10.1016/j.transproceed.2017.04.016
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Introduction. The presence of preformed HLA-reactive antibodies in recipient serum before transplantation has long been recognized as a prominent risk factor for a generally worse graft outcome. Screening and identification of HLA antibodies can be used to stratify patients into high-and low-risk categories. Materials and methods. We determined patients' anti-HLA antibodies using flow cytometry panel-reactive antibody (flowPRA) screening, specifying more than 5% after positive screening. According to the results of the screening test, patients were allocated to the induction immunosuppressive protocol according to the actual immunologic risk. Results. In the group of 78 patients, screening with flowPRA of anti-HLA antibodies was done twice a year. Patients were divided into 2 groups of immunologic risk (low or medium), and we chose the induction immunosuppressive protocol according to the risk. Stratification of the risk was correct, because the only predictor for development of acute rejection in the monitored period of 12 months was delayed graft function (odds ratio 33.2501; 95% confidence interval 10.0095-110.4508; P < .0001). The occurrence of acute rejection upon implementing the screening was reduced in our transplant center from 44% to 19% (P < .0001). No difference was recorded in the 12-month survival of grafts and patients according to the applied induction immunosuppressive protocol. Conclusion. We confirmed significantly reduced occurrence of acute rejection in the follow-up period of 12 months by using individualized induction according to flowPRA screening of anti-HLA antibodies. FIowPRA screening represents a suitable alternative for screening and specification of anti-HLA antibodies in case the Luminex methodology is unavailable.
引用
收藏
页码:1719 / 1723
页数:5
相关论文
共 50 条
  • [21] Bortezomib-Containing Multimodality Treatment for Antibody-Mediated Rejection with Anti-HLA and Anti-AT1R Antibodies after Kidney Transplantation
    Iesari, Samuele
    Lai, Quirino
    Favi, Evaldo
    Pisani, Francesco
    YONSEI MEDICAL JOURNAL, 2017, 58 (03) : 679 - 681
  • [22] Preconditioning Using Rituximab in Kidney Transplantation Reduces Incidence of Acute T-Cell Mediated Rejection and Prevents Development of Anti-HLA Antibody
    Hirose, T.
    Hotta, K.
    Iwahara, N.
    Shinohara, N.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2023, 23 (06) : S831 - S831
  • [23] Monitoring of anti-HLA antibodies after kidney transplantation - A prognostic factor for rejection severity an graft loss.
    Souza, Patricia S.
    Panajotopoulos, Nicolas
    Agena, Fabiana
    Ronda, Carla
    Rodrigues, Helcio
    Viggiani, Carlos S.
    David, Daisa S. R.
    Kalil, Jorge
    Ianhez, Luiz E.
    David-Neto, Elias
    Castro, Maria Cristina R.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2007, 7 : 288 - 288
  • [24] Prognostic Value of the Persistence of C1q-Binding Anti-HLA Antibodies in Acute Antibody-Mediated Rejection in Kidney Transplantation
    Bailly, Elodie
    Anglicheau, Dany
    Blancho, Gilles
    Gatault, Philippe
    Vuiblet, Vincent
    Chatelet, Valerie
    Morelon, Emmanuel
    Malvezzi, Paolo
    Parissiadis, Anne
    Tourret, Jerome
    Guidicelli, Gwendaline
    Sayegh, Johnny
    Mousson, Christiane
    Grimbert, Philippe
    Top, Isabelle
    Le Quintrec, Moglie
    Purgus, Raj
    Westeel, Pierre Francois
    Proust, Barbara
    Chabot, Valerie
    Lebranchu, Yvon
    Dehaut, Frederic
    Buchler, Matthias
    TRANSPLANTATION, 2018, 102 (04) : 688 - 698
  • [25] Hyperacute rejection after lung transplantation caused by preformed anti-HLA antibodies undetected by ELISA PRA screening
    Chabod, J.
    Masson, E.
    Stern, M.
    Tiberghien, P.
    TISSUE ANTIGENS, 2006, 67 (06): : 496 - 496
  • [26] PREFORMED LOW REACTIVE ANTI-HLA ANTIBODIES ARE ASSOCIATED WITH MAJORITY OF EARLY ANTIBODY-MEDIATED REJECTION IN RENAL TRANSPLANTATION.
    Brailey, P.
    Woodle, E. S.
    Alloway, R. R.
    Tevar, A. D.
    Cardi, M.
    Portwood, E.
    Mogilishetty, G.
    Govil, A.
    Rike, A. H.
    Walsh, R. C.
    Wall, G.
    Girnita, A. L.
    HUMAN IMMUNOLOGY, 2010, 71 : S68 - S68
  • [27] ANTIBODY MEDIATED REJECTION AFTER HEART TRANSPLANTATION WITH DE NOVO DONOR SPECIFIC ANTI-HLA ANTIBODIES: CASE REPORT
    Pashkova, I. A.
    Porhanov, V. A.
    Gilevich, I., V
    Kosmacheva, E. D.
    Kruberg, L. K.
    VOX SANGUINIS, 2013, 105 : 298 - 298
  • [28] Non-HLA Antibodies and the Risk of Antibody-mediated Rejection without Donor-specific Anti-HLA Antibodies After Lung Transplantation
    Comins-Boo, Alejandra
    Mora-Fernandez, Victor Manuel
    Padron-Aunceame, Paula
    Toriello-Suarez, Maria
    Gonzalez-Lopez, Elena
    Roa-Bautista, Adriel
    Castro-Hernandez, Carolina
    Iturbe-Fernandez, David
    Cifrian Jose, Manuel
    Lopez-Hoyos, Marco
    San Segundo, David
    TRANSPLANTATION PROCEEDINGS, 2025, 57 (01) : 73 - 76
  • [29] A NEW DIAGNOSTIC AND PRONOSTIC TOOL FOR ANTIBODY MEDIATED REJECTION IN KIDNEY TRANSPLANTATION: INTRAGRAFT DONOR SPECIFIC ANTI-HLA ANTIBODIES DETECTION
    Olagne, Jerome
    Caillard, Sophie
    Froelich, Nadine
    Essaidi, Arnaud
    Guntz, Philippe
    Gautier-Vargas, Gabriela
    Muller, Clotilde
    Gachet, Christian
    Moulin, Bruno
    Parissiadis, Anne
    TISSUE ANTIGENS, 2015, 85 (05): : 416 - 416
  • [30] A New Diagnostic and Pronostic Tool for Antibody Mediated Rejection in Kidney Transplantation: Intragraft Donor Specific Anti-HLA Antibodies Detection
    Olagne, J.
    Parissiadis, A.
    Caillard, S.
    Froelich, N.
    Marcellin, L.
    Muller, C.
    Gautier-Vargas, G.
    Perrin, P.
    Braun-Parvez, L.
    Heibel, F.
    Gachet, C.
    Moulin, B.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2015, 15