Functional imaging of murine hearts using accelerated self-gated UTE cine MRI

被引:11
|
作者
Motaal, Abdallah G. [1 ,2 ,3 ]
Noorman, Nils [1 ,2 ]
de Graaf, Wolter L. [1 ,2 ]
Hoerr, Verena [4 ]
Florack, Luc M. J. [3 ]
Nicolay, Klaas [1 ,2 ]
Strijkers, Gustav J. [1 ,2 ,5 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Biomed NMR, NL-5600 MB Eindhoven, Netherlands
[2] CIRE, Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Dept Math & Comp Sci, NL-5600 MB Eindhoven, Netherlands
[4] Univ Hosp Munster, Dept Clin Radiol, Munster, Germany
[5] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys, NL-1105 AZ Amsterdam, Netherlands
来源
关键词
Compressed sensing; UTE; Cardiac MRI; Functional imaging; CARDIOVASCULAR MAGNETIC-RESONANCE; ULTRASHORT TE; MOUSE; RESOLUTION;
D O I
10.1007/s10554-014-0531-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We introduce a fast protocol for ultra-short echo time (UTE) Cine magnetic resonance imaging (MRI) of the beating murine heart. The sequence involves a self-gated UTE with golden-angle radial acquisition and compressed sensing reconstruction. The self-gated acquisition is performed asynchronously with the heartbeat, resulting in a randomly undersampled kt-space that facilitates compressed sensing reconstruction. The sequence was tested in 4 healthy rats and 4 rats with chronic myocardial infarction, approximately 2 months after surgery. As a control, a non-accelerated self-gated multi-slice FLASH sequence with an echo time (TE) of 2.76 ms, 4.5 signal averages, a matrix of 192 x 192, and an acquisition time of 2 min 34 s per slice was used to obtain Cine MRI with 15 frames per heartbeat. Non-accelerated UTE MRI was performed with TE = 0.29 ms, a reconstruction matrix of 192 x 192, and an acquisition time of 3 min 47 s per slice for 3.5 averages. Accelerated imaging with 2x, 4x and 5x undersampled kt-space data was performed with 1 min, 30 and 15 s acquisitions, respectively. UTE Cine images up to 5x undersampled kt-space data could be successfully reconstructed using a compressed sensing algorithm. In contrast to the FLASH Cine images, flow artifacts in the UTE images were nearly absent due to the short echo time, simplifying segmentation of the left ventricular (LV) lumen. LV functional parameters derived from the control and the accelerated Cine movies were statistically identical.
引用
收藏
页码:83 / 94
页数:12
相关论文
共 50 条
  • [1] Functional imaging of murine hearts using accelerated self-gated UTE cine MRI
    Abdallah G. Motaal
    Nils Noorman
    Wolter L. de Graaf
    Verena Hoerr
    Luc M. J. Florack
    Klaas Nicolay
    Gustav J. Strijkers
    [J]. The International Journal of Cardiovascular Imaging, 2015, 31 : 83 - 94
  • [2] Accelerated self-gated UTE MRI of the murine heart
    Motaal, Abdallah G.
    Noorman, Nils
    De Graaf, Wolter L.
    Florack, Luc J.
    Nicolay, Klaas
    Strijkers, Gustav J.
    [J]. MEDICAL IMAGING 2014: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2014, 9038
  • [3] Accelerated self-gated UTE of murine heart
    Wolter L de Graaf
    Abdallah Motaal
    Nils Noorman
    Luc Florack
    Klaas Nicolay
    Gustav J Strijkers
    [J]. Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [4] Self-gated cardiac cine MRI
    Larson, AC
    White, RD
    Laub, G
    McVeigh, ER
    Li, DB
    Simonetti, OP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 93 - 102
  • [5] Self-Gated Cardiac Cine Imaging Using Phase Information
    Seo, Hyunseok
    Kim, Dongchan
    Oh, Changheun
    Park, HyunWook
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1216 - 1222
  • [6] Wireless, self-gated multi-slice cine MRI of mouse hearts in vivo
    Van Echteld, Cees J. A.
    te Boekhorst, Bernard C. M.
    Nederhoff, Marcel G. J.
    van de Kolk, Kees W. A.
    Nauerth, Arno
    [J]. JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2007, 42 : S238 - S238
  • [7] Automated rectilinear self-gated cardiac cine imaging
    Crowe, ME
    Larson, AC
    Zhang, Q
    Carr, J
    White, RD
    Li, DB
    Simonetti, OP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) : 782 - 788
  • [8] Respiratory self-gated 3D UTE for lung imaging in small animal MRI
    Tibiletti, Marta
    Bianchi, Andrea
    Kjorstad, Asmund
    Wundrak, Stefan
    Stiller, Detlef
    Rasche, Volker
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (02) : 739 - 745
  • [9] Self-Gated Fat-Suppressed Cardiac Cine MRI
    Ingle, R. Reeve
    Santos, Juan M.
    Overall, William R.
    McConnell, Michael V.
    Hu, Bob S.
    Nishimura, Dwight G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1764 - 1774
  • [10] Self-gated PROPELLER-encoded cine cardiac imaging
    Wang, Chi-Chung
    Huang, Teng-Yi
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1477 - 1485