Six months of hybrid closed loop in the real-world: An evaluation of children and young adults using the 670G system

被引:111
|
作者
Berget, Cari [1 ]
Messer, Laurel H. [1 ]
Vigers, Tim [2 ]
Frohnert, Brigitte I. [1 ]
Pyle, Laura [1 ,2 ]
Wadwa, R. Paul [1 ]
Driscoll, Kimberly A. [1 ,3 ]
Forlenza, Gregory P. [1 ]
机构
[1] Univ Colorado, Sch Med, Barbara Davis Ctr Childhood Diabet, Anschutz Campus, Aurora, CO 80045 USA
[2] Colorado Sch Publ Hlth, Dept Biostat & Informat, Aurora, CO USA
[3] Univ Florida, Dept Clin & Hlth Psychol, Gainesville, FL USA
关键词
pediatrics; artificial pancreas; automated insulin delivery; continuous glucose monitor; INSULIN DELIVERY-SYSTEM; QUALITY-OF-LIFE; PROBLEM AREAS; TYPE-1; ADOLESCENTS;
D O I
10.1111/pedi.12962
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To describe glycemic and psychosocial outcomes in youth with type 1 diabetes using a hybrid closed loop (HCL) system. Subjects Youth with type 1 diabetes (2-25 years) starting the 670G HCL system for their diabetes care were enrolled in an observational study. Methods Prospective data collection occurred during routine clinical care and included glycemic variables (sensor time in range [70-180 mg/dL], HbA1c), and psychosocial variables (Hypoglycemia Fear Survey [HFS]; Problem Areas in Diabetes [PAID]). Mixed models were used to analyze change across time. Results Ninety-two youth (mean age 15.7 +/- 3.6 years, 50% female, HbA1c 8.8% +/- 1.8%) started HCL for their diabetes care. Youth used Auto Mode 65.5% +/- 3.0% of the time at month 1, which decreased to 51.2% +/- 3.4% at month 6 (P = .001). Sensor time in range increased from 50.7% +/- 1.8% at baseline to 56.9% +/- 2.1% at 6 months (P = .007). HbA1c decreased from 8.7% +/- 0.2% at baseline to 8.4% +/- 0.2% after 6 months of use (P <= .0001), with the greatest HbA1c decline in participants with high baseline HbA1c. Increased percent time in auto mode was associated with lower HbA1c (P = .02). Thirty percent of youth discontinued HCL in the first 6 months of use. There were no changes in the HFS or PAID scores across time. Conclusions HCL use is associated with improved glycemic control and no change in psychosocial outcomes in this clinical sample. The decline in HCL use across time suggests that youth experience barriers in sustaining use of HCL. Further research is needed to understand reasons for HCL discontinuation and determine intervention strategies.
引用
收藏
页码:310 / 318
页数:9
相关论文
共 50 条
  • [41] Retrospective Analysis of 3-Month Real-World Glucose Data After the MiniMed 670G System Commercial Launch
    Stone, Michael P.
    Agrawal, Pratik
    Chen, Xiaoxiao
    Liu, Margaret
    Shin, John
    Cordero, Toni L.
    Kaufman, Francine R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (10) : 689 - 692
  • [42] ALGORITHM-DRIVEN PERSONALIZED INSULIN DELIVERY: INSIGHTS FROM REAL-WORLD USE OF THE MINIMED™ 670G SYSTEM IN EUROPE
    Cohen, O.
    Da Silva, J.
    Arrieta, A.
    Castaneda, J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A76 - A76
  • [43] EVALUATION OF THE MINIMED™ 670G SYSTEM PREDICTIVE LOW GLUCOSE MANAGEMENT FEATURE IN CHILDREN
    Forlenza, G.
    Shulman, D.
    Wood, M.
    Bode, B.
    Pinhas-Hamiel, O.
    Kaiserman, K.
    Buckingham, B.
    Liljenquist, D.
    Bailey, T.
    Shin, J.
    Huang, S.
    Cordero, T.
    Lee, S.
    Kaufman, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A19 - A20
  • [44] Real-World Use of the Advanced Hybrid Closed-Loop System Camaps FX with Two Different CGM Systems in Pregnancy and Young Children
    Beato-Vibora, Pilar I.
    Gil-Poch, Estela
    Arroyo-Diez, Francisco Javier
    DIABETES, 2024, 73
  • [45] Hybrid closed loop in adolescents and young adults with type 1 diabetes: a real world study
    Ung, M.
    Penfornis, A.
    Amadou-Kerangoarec, C.
    Eroukhmanoff, J.
    DIABETOLOGIA, 2024, 67 : S367 - S368
  • [46] MiniMed 670G hybrid closed loop artificial pancreas system for the treatment of type 1 diabetes mellitus: overview of its safety and efficacy
    Saunders, Aria
    Messer, Laurel H.
    Forlenza, Gregory P.
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (10) : 845 - 853
  • [47] THE INTRODUCTION OF MINIMED 670G HYBRID CLOSED LOOP INSULIN PUMP AUTO MODE SYSTEM IMPROVES GLYCAEMIC CONTROL IN ROUTINE CLINICAL PRACTICE
    Skvarca, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A177 - A177
  • [48] The Effect of Prior Continuous Glucose Monitoring Use on Glycemic Outcomes in the Pivotal Trial of the MiniMed 670G Hybrid Closed-Loop System
    Cordero, Toni L.
    Garg, Satish K.
    Brazg, Ronald
    Bailey, Timothy S.
    Shin, John
    Lee, Scott W.
    Kaufman, Francine R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (12) : 749 - 752
  • [49] Real-World User and Clinician Perspective and Experience with MiniMed™ 780G Advanced Hybrid Closed Loop System
    Kesavadev, Jothydev
    Basanth, Anjana
    Krishnan, Gopika
    Shankar, Arun
    Sanal, Geethu
    Jothydev, Sunitha
    DIABETES THERAPY, 2023, 14 (08) : 1319 - 1330
  • [50] Real-World User and Clinician Perspective and Experience with MiniMed™ 780G Advanced Hybrid Closed Loop System
    Jothydev Kesavadev
    Anjana Basanth
    Gopika Krishnan
    Arun Shankar
    Geethu Sanal
    Sunitha Jothydev
    Diabetes Therapy, 2023, 14 : 1319 - 1330