Microchannel System Simulation for a Neutron Production Target to be used in the Boron Neutron Capture Therapy

被引:1
|
作者
Gagetti, Leonardo [1 ,2 ,3 ]
Suarez Anzorena, Manuel [2 ,3 ]
del Grosso, Mariela [1 ,2 ]
Kreiner, Andres J. [1 ,2 ,3 ]
机构
[1] CNEA, Gerencia Invest & Aplicac, Ave Gen Paz 1499, San Martin, Buenos Aires, Argentina
[2] Univ Nacl San Martin UNSAM, Escuela Ciencia & Tecnol, San Martin, Buenos Aires, Argentina
[3] Consejo Nacl Invest Cient & Tecn, Buenos Aires, DF, Argentina
关键词
Microchannels; BNCT; Simulations;
D O I
10.1016/j.mspro.2015.04.097
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Microchannel system simulations have been performed in this work based on the thermal resistance model developed by Phillips (1988) and followed by Zhimin (1997). As it appears in the bibliography [ Phillips (1988), Zhimin et al. (1997), Ludewigt et al. (1997), Tuckerman et al. (1981), Knight et al. (1992)], this system should be capable of removing 1 kW/cm(2), for this reason it is being taken into account for the design of a neutron production target with accelerators. Based on the previously mentioned model, two codes were written in MATLAB programming platform, that solve the equations of such model in an iterative way under constant pressure between the microchannel ends and constant pumping power, respectively. The codes calculate the total thermal resistance (and its components) of the microchannel system for a given geometry, in addition to the hydrodynamic variables and the system adimentional numbers (Re and Nu). The codes report total thermal resistance values and adimentional numbers comparable to those reported in different publications [ Phillips (1988), Zhimin et al. (1997), Ludewigt et al. (1997)], discrepancies lower than 10% have been found. For this reason it is being considered to design a heat sink that drains the energy depositedby the accelerator's incident beam. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:461 / 470
页数:10
相关论文
共 50 条
  • [21] Fast Neutron Beams for Boron Neutron Capture Therapy?
    Wolber, Gerd
    Zeitschrift fur Medizinische Physik, 2004, 14 (01): : 55 - 63
  • [22] Liposomal boron delivery system for neutron capture therapy
    Nakamura, Hiroyuki
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2008, 128 (02): : 193 - 208
  • [23] A COMPACT NEUTRON SOURCE FOR BORON NEUTRON CAPTURE THERAPY
    Golubev, S. V.
    Izotov, I. V.
    Razin, S. V.
    Sidorov, A. V.
    Skalyga, V. A.
    RADIOPHYSICS AND QUANTUM ELECTRONICS, 2017, 59 (8-9) : 682 - 689
  • [24] Utilizing neutron generators in boron neutron capture therapy
    Metwally, Walid A.
    Adel, Yumna
    Dalah, Entesar Z.
    Al-Omari, Husam
    APPLIED RADIATION AND ISOTOPES, 2021, 174
  • [25] Capillary neutron optics for boron neutron capture therapy
    Xiao, QF
    Sharov, VA
    Gibson, DM
    Chen, H
    Mildner, DFR
    Downing, RG
    CANCER NEUTRON CAPTURE THERAPY, 1996, : 399 - 406
  • [26] A Compact Neutron Source for Boron Neutron Capture Therapy
    S. V. Golubev
    I. V. Izotov
    S. V. Razin
    A. V. Sidorov
    V. A. Skalyga
    Radiophysics and Quantum Electronics, 2017, 59 : 682 - 689
  • [27] Boron encapsulated in a liposome can be used for combinational neutron capture therapy
    Li, Jiyuan
    Sun, Qi
    Lu, Chuanjie
    Xiao, Han
    Guo, Zhibin
    Duan, Dongban
    Zhang, Zizhu
    Liu, Tong
    Liu, Zhibo
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [28] Boron encapsulated in a liposome can be used for combinational neutron capture therapy
    Jiyuan Li
    Qi Sun
    Chuanjie Lu
    Han Xiao
    Zhibin Guo
    Dongban Duan
    Zizhu Zhang
    Tong Liu
    Zhibo Liu
    Nature Communications, 13
  • [29] The physics of the boron neutron capture therapy
    Bruno-Machado, A. C.
    Fortes, E. C. F. S.
    Tijero, M. C.
    REVISTA BRASILEIRA DE ENSINO DE FISICA, 2010, 32 (04):
  • [30] Boron and gadolinium neutron capture therapy
    Salt, C
    Lennox, AJ
    Takagaki, M
    Maguire, JA
    Hosmane, NS
    RUSSIAN CHEMICAL BULLETIN, 2004, 53 (09) : 1871 - 1888