Optimization of Cooling System of Linac Collinear Load

被引:1
|
作者
Xu, Guixiang [1 ]
Shen, Lianguan [1 ]
Shu, Zhao [1 ]
Sun, Yuan [1 ]
Pei, Yuanji [2 ]
机构
[1] USTC, Dept Precis Machinery & Precis Instrumentat, Hefei, Peoples R China
[2] USTC, Hefei Natl Synchrotron Radiat Lab, Hefei, Peoples R China
来源
关键词
Collinear Load; Cooling system; LINAC; FeSiAl; Frequency shift; DESIGN;
D O I
10.4028/www.scientific.net/AMR.291-294.2272
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Collinear load, coating with microwave-absorbing material, determined to linear accelerator (LINAC) to absorb the remnant power. It forms a part of actual accelerating structure and substitutes for traditional waveguide-type load to make the accelerating structure compacter and size smaller. In order to guarantee operational reliability, it is necessary to keep the operation frequency of cavities of the collinear load at 2856MHz and at a small shift. An approach utilized to accurately evaluate the frequency change caused by non-uniform thermal deformation is presented and a strategy for optimizing its cooling system is also described simultaneously. A six-cavity collinear load, coated with FeSiAl alloy, is researched. The results show that the frequency shift of cavities of the collinear load can be controlled within -56 similar to 35kHz, when it runs on 2856MHz and 2 pi/3 mode and the structure of its cooling system becomes much more compact and economic.
引用
收藏
页码:2272 / +
页数:2
相关论文
共 50 条
  • [11] Space Cooling Load Monitoring System With IoT
    Miqdad, A.
    Kadir, K.
    Ahmed, Syed Faiz
    Janin, Zuriati
    Khan, Sheroz
    2018 IEEE 5TH INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATION (ICSIMA), 2018,
  • [12] A robust optimization model for designing the building cooling source under cooling load uncertainty
    Niu, Jide
    Tian, Zhe
    Lu, Yakai
    Zhao, Hongfang
    Lan, Bo
    APPLIED ENERGY, 2019, 241 : 390 - 403
  • [13] Multi-objective optimization of district cooling systems considering cooling load characteristics
    He, Junjie
    Guo, Zihao
    Li, Yajun
    ENERGY CONVERSION AND MANAGEMENT, 2023, 281
  • [14] Optimization procedure of blade cooling system
    Silesian University of Technology, Institute of Power Engineering and Turbomachinery, ul. Konarskiego 18, 44-100 Gliwice, Poland
    不详
    Arch. Thermodyn., 2006, 3 (63-82):
  • [15] Turbine Blade Cooling System Optimization
    Girardeau, Julian
    Pailhes, Jerome
    Sebastian, Patrick
    Pardo, Frederic
    Nadeau, Jean-Pierre
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2013, 135 (06):
  • [16] COOLING SYSTEM OPTIMIZATION OF COMBUSTOR LINERS
    Pucci, Egidio
    Cerutti, Matteo
    Peano, Guido
    Facchini, Bruno
    Andreini, Antonio
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 5A, 2017,
  • [17] Cooling load density analysis and optimization for an endoreversible air refrigerator
    Zhou, SB
    Chen, LG
    Sun, FR
    Wu, C
    OPEN SYSTEMS & INFORMATION DYNAMICS, 2001, 8 (02): : 147 - 155
  • [18] Optimization of cooling load for a lecture theatre in a composite climate in India
    Kulkarni, K.
    Sahoo, P. K.
    Mishra, M.
    ENERGY AND BUILDINGS, 2011, 43 (07) : 1573 - 1579
  • [19] Cooling load density optimization of an irreversible simple Brayton refrigerator
    Zhou, SB
    Chen, LG
    Sun, FR
    Wu, C
    OPEN SYSTEMS & INFORMATION DYNAMICS, 2002, 9 (04): : 325 - 337
  • [20] Optimization of a plant cooling system design
    Kolak, Doug
    Plant Engineering, 2020, : 39 - 43