Optimization of Cooling System of Linac Collinear Load

被引:1
|
作者
Xu, Guixiang [1 ]
Shen, Lianguan [1 ]
Shu, Zhao [1 ]
Sun, Yuan [1 ]
Pei, Yuanji [2 ]
机构
[1] USTC, Dept Precis Machinery & Precis Instrumentat, Hefei, Peoples R China
[2] USTC, Hefei Natl Synchrotron Radiat Lab, Hefei, Peoples R China
来源
关键词
Collinear Load; Cooling system; LINAC; FeSiAl; Frequency shift; DESIGN;
D O I
10.4028/www.scientific.net/AMR.291-294.2272
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Collinear load, coating with microwave-absorbing material, determined to linear accelerator (LINAC) to absorb the remnant power. It forms a part of actual accelerating structure and substitutes for traditional waveguide-type load to make the accelerating structure compacter and size smaller. In order to guarantee operational reliability, it is necessary to keep the operation frequency of cavities of the collinear load at 2856MHz and at a small shift. An approach utilized to accurately evaluate the frequency change caused by non-uniform thermal deformation is presented and a strategy for optimizing its cooling system is also described simultaneously. A six-cavity collinear load, coated with FeSiAl alloy, is researched. The results show that the frequency shift of cavities of the collinear load can be controlled within -56 similar to 35kHz, when it runs on 2856MHz and 2 pi/3 mode and the structure of its cooling system becomes much more compact and economic.
引用
收藏
页码:2272 / +
页数:2
相关论文
共 50 条
  • [1] Design of collinear load for S-band compact electron LINAC
    Zhang, Fang
    Shen, Lianguan
    Pei, Yuanji
    RESULTS IN PHYSICS, 2017, 7 : 751 - 756
  • [2] rf conditioning and breakdown analysis of a traveling wave linac with collinear load cells
    Chen, Qushan
    Hu, Tongning
    Qin, Bin
    Xiong, Yongqian
    Fan, Kuanjun
    Pei, Yuanji
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2018, 21 (04)
  • [3] Numerical analysis and design of collinear load for S-band linac based on FeSiAl material
    Sun, Yuan
    Shen, Lianguan
    Wang, Xiucui
    Shu, Zhao
    Pei, Yuanji
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (03): : 883 - 887
  • [4] A MODULAR COOLING SYSTEM FOR THE MEA HIGH DUTY FACTOR ELECTRON LINAC
    NOOMEN, JG
    GEUZEBROEK, N
    SCHIEBAAN, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 147 - 147
  • [5] A MODULAR COOLING SYSTEM FOR THE MEA HIGH DUTY FACTOR ELECTRON LINAC
    NOOMEN, JG
    GEUZEBROEK, N
    SCHIEBAAN, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 3082 - 3084
  • [6] Impacts of cooling load calculation uncertainties on the design optimization of building cooling systems
    Gang, Wenjie
    Wang, Shengwei
    Shan, Kui
    Gao, Diance
    ENERGY AND BUILDINGS, 2015, 94 : 1 - 9
  • [7] Optimization of Cooling Load for Different Greenhouse Models in Malaysia
    Mohammad, Abdulrahman Th.
    Bin Mat, Sohif
    Alrubaih, M. S.
    Al-abidi, Abduljalil A.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2014, 4 (01): : 42 - 48
  • [8] Cooling water mass flow optimization for indirect dry cooling system of thermal power unit under variable output load
    Wu, Tao
    Wei, Huimin
    Ge, Zhihua
    Yang, Lijun
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 133 : 1 - 10
  • [9] Optimization of a cooling system: the cooling of pilgered seamless tubes
    Carscallen, W.E.
    Jeswiet, J.
    Oosthuizen, P.H.
    CIRP Annals - Manufacturing Technology, 1994, 43 (01) : 223 - 227
  • [10] OPTIMIZATION OF LOAD SHEDDING SYSTEM
    HALEVI, Y
    KOTTICK, D
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1993, 8 (02) : 207 - 213