A 64-Channel Neuron Recording System

被引:0
|
作者
Lo, Yi-Kai [1 ]
Liu, Wentai [1 ]
Chen, Kuanfu [1 ]
Tsai, Ming-Hsien [2 ]
Hsueh, Fu-Lung [2 ]
机构
[1] Univ Calif Santa Cruz, Dept Elect Engn, Santa Cruz, CA 95064 USA
[2] Taiwan Semicond Manufacturing Co Ltd, Hsinchu 300, Taiwan
来源
2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2011年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a fully integrated low-power neuron recording front-end system in TSMC 65nm 1p6m CMOS technology. The proposed system is comprised of two recording modules, each containing 32 recording channels with tunable bandwidth and gain, a 32-to-1 multiplexer, one differential successive approximation register (SAR) analog-to-digital converter (ADC) with programmable sampling rate on each channel, and a digital control module to govern the signal digitization as well as to encode and serialize the digitized neuron signal from two ADCs. The recording amplifier presents a low power and low noise merits of 6 mu W and input-referred noise of 3.8 mu V-rms. The ADC digitizes the neural signal at a sampling rate of 40kS/s with 9-bit resolution. The overall power consumption of the entire system is 2.56mW and occupies an area of 3x4mm(2).
引用
收藏
页码:2862 / 2865
页数:4
相关论文
共 50 条
  • [21] A Miniature Wireless 64-channel System for Monitoring Gastrointestinal Activity
    Javan-Khoshkholgh, Amir
    Alrofati, Wahib
    Abukhalaf, Zaid
    Ibrahim, Ahmed
    Kiani, Mehdi
    Farajidavar, Aydin
    PROCEEDINGS OF THE 2018 IEEE/MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2018, : 118 - 120
  • [22] A wireless 64-channel ECoG recording Electronic for implantable monitoring and BCI applications: WIMAGINE
    Charvet, G.
    Foerster, M.
    Chatalic, G.
    Michea, A.
    Porcherot, J.
    Bonnet, S.
    Filipe, S.
    Audebert, P.
    Robinet, S.
    Josselin, V.
    Reverdy, J.
    D'Errico, R.
    Sauter, F.
    Mestais, C.
    Benabid, A. L.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 783 - 786
  • [23] A 64-Channel Versatile Neural Recording SoC With Activity-Dependent Data Throughput
    Liu, Yan
    Luan, Song
    Williams, Ian
    Rapeaux, Adrien
    Constandinou, Timothy G.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (06) : 1344 - 1355
  • [24] A 64-channel ASIC for TOFPET applications
    Rolo, Manuel D.
    Bugalho, Ricardo
    Goncalves, Fernando
    Rivetti, Angelo
    Mazza, Giovanni
    Silva, Jose C.
    Silva, Rui
    Varela, Joao
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1460 - 1464
  • [25] 64-Channel Optical Pulse Stacker
    Kong, Yong
    Liu, Qi Zhong
    Deng, Chen
    Huang, Xiu Jiang
    Chen, Guang Hui
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2009, 27 (15) : 3017 - 3020
  • [26] 64-CHANNEL SHARED PCM CODEC
    不详
    ELECTRONICS & WIRELESS WORLD, 1987, 93 (1615): : 507 - 507
  • [27] 64-channel ultrasound transducer amplifier
    Morizio, J
    Guhados, S
    Castellucci, J
    von Ramm, O
    2003 SOUTHWEST SYMPOSIUM ON MIXED-SIGNAL DESIGN, 2003, : 228 - 232
  • [28] Monolithically Integrated 64-channel WDM Channel Selector
    Kikuchi, Nobuhiro
    Shibata, Yasuo
    Tohmori, Yuichi
    NTT Technical Review, 2003, 1 (07): : 43 - 49
  • [29] Monolithically integrated 64-channel WDM channel selector
    Kikuchi, Nobuhiro
    Shibata, Yasuo
    Tohmori, Yuichi
    NTT R and D, 2002, 51 (11): : 886 - 892
  • [30] WIMAGINE: A wireless, low power, 64-channel ECoG recording platform for implantable BCI applications
    Charvet, G.
    Foerster, M.
    Filipe, S.
    Porcherot, J.
    Beche, J. F.
    Guillemaud, R.
    Audebert, P.
    Regis, G.
    Zongo, B.
    Robinet, S.
    Condemine, C.
    Tetu, Y.
    Sauter, F.
    Mestais, C.
    Benabid, A. L.
    2011 5TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2011, : 356 - 359