An analytic description of electrodynamic dispersion in free-flow zone electrophoresis

被引:19
|
作者
Dutta, Debashis [1 ]
机构
[1] Univ Wyoming, Dept Chem, Laramie, WY 82071 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Band broadening; Electrodynamic dispersion; Electroosmotic cross-flow; Free-flow zone electrophoresis; Method-of-moments; ELECTROKINETIC TRANSPORT; CHARGED SAMPLES; ZETA POTENTIALS; BAND-WIDTH; SEPARATION; RESOLUTION; MICRO; CHROMATOGRAPHY; PURIFICATION; SIMULATION;
D O I
10.1016/j.chroma.2015.05.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present work analyzes the electrodynamic dispersion of sample streams in a free-flow zone electrophoresis (FFZE) chamber resulting due to partial or complete blockage of electroosmotic flow (EOF) across the channel width by the sidewalls of the conduit. This blockage of EOF has been assumed to generate a pressure-driven backflow in the transverse direction for maintaining flow balance in the system. A parallel-plate based FFZE device with the analyte stream located far away from the channel side regions has been considered to simplify the current analysis. Applying a method-of-moments formulation, an analytic expression was derived for the variance of the sample zone at steady state as a function of its position in the separation chamber under these conditions. It has been shown that the increase in stream broadening due to the electrodynamic dispersion phenomenon is additive to the contributions from molecular diffusion and sample injection, and simply modifies the coefficient for the hydrodynamic dispersion term for a fixed lateral migration distance of the sample stream. Moreover, this dispersion mechanism can dominate the overall spatial variance of analyte zones when a significant fraction of the EOF is blocked by the channel sidewalls. The analysis also shows that analyte streams do not undergo any hydrodynamic broadening due to unwanted pressure-driven cross-flows in an FFZE chamber in the absence of a transverse electric field. The noted results have been validated using Monte Carlo simulations which further demonstrate that while the sample concentration profile at the channel outlet approaches a Gaussian distribution only in FFZE chambers substantially longer than the product of the axial pressure-driven velocity and the characteristic diffusion time in the system, the spatial variance of the exiting analyte stream is well described by the Taylor-Aris dispersion limit even in analysis ducts much shorter than this length scale. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 50 条
  • [21] Micro free-flow electrophoresis: theory and applications
    Turgeon, Ryan T.
    Bowser, Michael T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (01) : 187 - 198
  • [22] FREE-FLOW ELECTROPHORESIS IN SOLUTIONS OF BORAX AND MANNITOL
    SHUKUN, SA
    GAVRYUSHKIN, AV
    BREZGUNOV, VN
    ZAVYALOV, VP
    ELECTROPHORESIS, 1986, 7 (12) : 572 - 574
  • [23] Reducing pH Gradients in Free-Flow Electrophoresis
    Agostino, Fletcher J.
    Cherney, Leonid T.
    Kanoatov, Mirzo
    Krylov, Sergey N.
    ANALYTICAL CHEMISTRY, 2014, 86 (12) : 5656 - 5660
  • [24] Counterbalancing hydrodynamic sample distortion effects increases resolution of free-flow zone electrophoresis
    Weber, G
    Bauer, J
    ELECTROPHORESIS, 1998, 19 (07) : 1104 - 1109
  • [25] SEPARATION OF HUMAN LYMPHOCYTES BY FREE-FLOW ELECTROPHORESIS
    STEIN, G
    FLAD, HD
    PABST, R
    TREPEL, F
    BIOMEDICINE EXPRESS, 1973, 19 (09): : 388 - 391
  • [26] PURIFICATION OF MONOCLONAL IGGS BY FREE-FLOW ELECTROPHORESIS
    OSTREM, JA
    MARQUEZ, R
    RHODES, B
    KOSECKI, R
    BARSTOW, L
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 135 - IAEC
  • [27] MATHEMATICAL-MODEL OF FREE-FLOW ELECTROPHORESIS
    GIANNOVARIO, JA
    GRIFFIN, RN
    GRAY, EL
    JOURNAL OF CHROMATOGRAPHY, 1978, 153 (02): : 329 - 352
  • [28] Enhancement in MS-based peptide detection by microfluidic free-flow zone electrophoresis
    Kinde, Tristan F.
    Hess, Natalie
    Dutta, Debashis
    ELECTROPHORESIS, 2020, 41 (7-8) : 545 - 553
  • [29] Free-flow electrophoresis in proteome sample preparation
    Wildgruber, Robert
    Weber, Gerhard
    Wise, Petra
    Grimm, Daniela
    Bauer, Johann
    PROTEOMICS, 2014, 14 (4-5) : 629 - 636
  • [30] ENDOSOME AND LYSOSOME PURIFICATION BY FREE-FLOW ELECTROPHORESIS
    MARSH, M
    METHODS IN CELL BIOLOGY, 1989, 31 : 319 - 334