Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy

被引:34
|
作者
Gao, Hao [1 ]
Liu, Jiulong [2 ]
Lin, Yuting [1 ]
Gan, Gregory N. [1 ]
Pratx, Guillem [3 ]
Wang, Fen [1 ]
Langen, Katja [4 ]
Bradley, Jeffrey D. [4 ]
Rotondo, Ronny L. [1 ]
Li, Harold H. [1 ]
Chen, Ronald C. [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiat Oncol, Kansas City, KS 66103 USA
[2] Chinese Acad Sci, Acad Math & Syst Sci, Inst Computat Math & Sci Engn Comp, LSEC, Beijing, Peoples R China
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[4] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
dose rate optimization; FLASH dose modifying factor; IMPT; proton therapy; RADIATION-THERAPY; IRRADIATION;
D O I
10.1002/mp.15356
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Compared to CONV-RT (with conventional dose rate), FLASH-RT (with ultra-high dose rate) can provide biological dose sparing for organs-at-risk (OARs) via the so-called FLASH effect, in addition to physical dose sparing. However, the FLASH effect only occurs, when both dose and dose rate meet certain minimum thresholds. This work will develop a simultaneous dose and dose rate optimization (SDDRO) method accounting for both FLASH dose and dose rate constraints during treatment planning for pencil-beam-scanning proton therapy. Methods SDDRO optimizes the FLASH effect (specific to FLASH-RT) as well as the dose distribution (similar to CONV-RT). The nonlinear dose rate constraint is linearized, and the reformulated optimization problem is efficiently solved via iterative convex relaxation powered by alternating direction method of multipliers. To resolve and quantify the generic tradeoff of FLASH-RT between FLASH and dose optimization, we propose the use of FLASH effective dose based on dose modifying factor (DMF) owing to the FLASH effect. Results FLASH-RT via transmission beams (TB) (IMPT-TB or SDDRO) and CONV-RT via Bragg peaks (BP) (IMPT-BP) were evaluated for clinical prostate, lung, head-and-neck (HN), and brain cases. Despite the use of TB, which is generally suboptimal to BP for normal tissue sparing, FLASH-RT via SDDRO considerably reduced FLASH effective dose for high-dose OAR adjacent to the target. For example, in the lung SBRT case, the max esophageal dose constraint 27 Gy was only met by SDDRO (24.8 Gy), compared to IMPT-BP (35.3 Gy) or IMPT-TB (36.6 Gy); in the brain SRS case, the brain constraint V12Gy <= 15cc was also only met by SDDRO (13.7cc), compared to IMPT-BP (43.9cc) or IMPT-TB (18.4cc). In addition, SDDRO substantially improved the FLASH coverage from IMPT-TB, e.g., an increase from 37.2% to 67.1% for lung, from 39.1% to 58.3% for prostate, from 65.4% to 82.1% for HN, from 50.8% to 73.3% for the brain. Conclusions Both FLASH dose and dose rate constraints are incorporated into SDDRO for FLASH-RT that jointly optimizes the FLASH effect and physical dose distribution. FLASH effective dose via FLASH DMF is introduced to reconcile the tradeoff between physical dose sparing and FLASH sparing, and quantify the net effective gain from CONV-RT to FLASH-RT.
引用
收藏
页码:2014 / 2025
页数:12
相关论文
共 50 条
  • [21] Pencil Beam Dose Algorithm for Intensity Modulated Proton Therapy with Scanning Proton Beams
    Wang, H.
    Zheng, H.
    Cao, R.
    Jia, J.
    Song, J.
    He, T.
    Wu, Y.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [22] Commissioning of a clinical pencil beam scanning proton therapy unit for ultra-high dose rates (FLASH)
    Nesteruk, Konrad P.
    Togno, Michele
    Grossmann, Martin
    Lomax, Anthony J.
    Weber, Damien C.
    Schippers, Jacobus M.
    Safai, Sairos
    Meer, David
    Psoroulas, Serena
    MEDICAL PHYSICS, 2021, 48 (07) : 4017 - 4026
  • [23] Neutron Dose Equivalent Evaluation for Pencil Beam Scanning Proton Therapy with Apertures
    Geng, C.
    Schuemann, J.
    Moteabbed, M.
    Paganetti, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3466 - 3466
  • [24] Effect of Scanning Beam for Superficial Dose in Proton Therapy
    Moskvin, Vadim P.
    Estabrook, Neil C.
    Cheng, Chee-Wai
    Das, Indra J.
    Johnstone, Peter A. S.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (05) : 643 - 652
  • [25] Time-resolved dose rate measurements in pencil beam scanning proton FLASH therapy with a fiber-coupled scintillator detector system
    Kanouta, Eleni
    Poulsen, Per Rugaard
    Kertzscher, Gustavo
    Sitarz, Mateusz Krzysztof
    Sorensen, Brita Singers
    Johansen, Jacob Graversen
    MEDICAL PHYSICS, 2023, 50 (04) : 2450 - 2462
  • [26] Pencil Beam Proton Flash Therapy, the challenge of scanning.
    Pin, A.
    Hotoiu, L.
    Deffet, S.
    Sterpin, E.
    Labarbe, R.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S747 - S748
  • [27] Exploratory study of seed spots analysis to characterize dose and linear-energy-transfer effect in adverse event initialization of pencil-beam-scanning proton therapy
    Yang, Yunze
    Patel, Samir H.
    Bridhikitti, Jidapa
    Wong, William W.
    Halyard, Michele Y.
    McGee, Lisa A.
    Rwigema, Jean-Claude M.
    Schild, Steven E.
    Vora, Sujay A.
    Liu, Tianming
    Bues, Martin
    Fatyga, Mirek
    Foote, Robert L.
    Liu, Wei
    MEDICAL PHYSICS, 2022, 49 (09) : 6237 - 6252
  • [28] Need for Beam Collimation Design for Dose-Rate Fall-Off in Proton Flash Treatment Using Pencil Beam Scanning
    Bentefour, E.
    Sawant, A.
    Mossahebi, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [29] Dose and dose rate objectives in Bragg peak and shoot-through beam orientation optimization for FLASH proton therapy
    Ramesh, Pavitra
    Gu, Wenbo
    Ruan, Dan
    Sheng, Ke
    MEDICAL PHYSICS, 2022, 49 (12) : 7826 - 7837
  • [30] Skin Dose in Proton Pencil Beam Scanning for Pediatric Patients
    Axente, M.
    Moskvin, V.
    Shin, J.
    Tsiamas, P.
    Merchant, T.
    Farr, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3498 - 3498