Development and Validation by Reverse Phase High Performance Liquid Chromatography Method for the Estimation of Piperine and Coenzyme Q10 in Bulk and Pharmaceutical Dosage Form

被引:2
|
作者
Sarkar, M. [1 ]
Bag, Puja [1 ]
Kumar, B. [1 ]
Chawla, Pooja A. [1 ]
机构
[1] ISF Coll Pharm, Dept Pharmaceut Anal, Moga 142001, Punjab, India
关键词
Piperine; coenzyme Q10; reversed phase high performance liquid chromatography; method validation; limit of detection; limit of quantitation; Q(10); ABSORPTION; PEPPER;
D O I
10.36468/pharmaceutical-sciences.875
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Today people are focused on their health, as good health is a key to the happiness of our life. Medicine takes a big responsibility to take care of our health. Various supplements are available to meet the nutritional requirement. One such supplement is a combination of piperine and coenzyme Q10. The medicines have to be analyzed properly before introducing them to the market. As no analytical method is available for simultaneous estimation of the combination, hence an attempt was made to develop a validated method for the estimation of piperine and coenzyme Q10 simultaneously in bulk and its dosage form. A simple, precise, accurate and validated reversed phase high performance liquid chromatography technique was developed for the estimation of piperine and coenzyme Q10 in bulk and its tablet formulation. In this developed method, Waters X Bridge C-18 column (250 mmx4.6 mm, 5 mu m) was used as a stationary phase and acetonitrile, tetrahydrofuran and water was used in 65:32:3 (v/v) ratio as mobile phase with 1 ml/min flow rate. This isocratic separation was accomplished using Waters 2707 Autosampler high performance liquid chromatography system, Waters 515 solvent delivery system, with photodiode array detector detection at 275 nm. Chromatographic data was processed by Empower 2 software. The retention times of coenzyme Q10 and piperine were 4.56 and 8.19 min respectively. The linearity ranges have lied between 4-6 mu g/ml, 240-360 mu g/ml for piperine and coenzyme Q10 respectively with 0.997 as correlation coefficient for both.
引用
收藏
页码:1208 / 1214
页数:7
相关论文
共 50 条
  • [41] Development and Validation of RP-HPLC Method for the Estimation of Nilotinib in Bulk and Pharmaceutical Dosage form
    Barla, Archana
    Buralla, Kiran Kumar
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL INVESTIGATION, 2020, 10 (03) : 364 - 367
  • [42] Development and Validation of Reversed-phase High-performance Liquid Chromatography Method for Simultaneous Estimation of Desonide and Curcumin in Topical Dosage Form
    Waman, Rahul L.
    Loksh, Kavita R.
    ASIAN JOURNAL OF PHARMACEUTICS, 2024, 18 (03) : 866 - 871
  • [43] Development and Validation of Analytical Method for Determination of Esomeprazole in Pharmaceutical Effluents Using Reverse Phase High Performance Liquid Chromatography
    Tulasi, S. Lakshmi
    Swamy, A. V. V. S.
    Peddi, Pavani
    Ganji, Ramana Reddy
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL AND PHYTOPHARMACOLOGICAL RESEARCH, 2019, 9 (01): : 71 - 80
  • [44] Quality by Design Based Stability Indicating Quantitative Reverse Phase High Performance Liquid Chromatography Method Development and Validation for Bilastine in Tablet Dosage Form
    Pandya, D. J.
    Patel, C. N.
    Patel, Khushbu
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 86 (02) : 683 - 691
  • [45] Simultaneous estimation of Rosuvastatin calcium and Ezetimibe in tablet dosage form by reverse phase high performance liquid chromatography
    Sharma, Smita
    Sharma, M. C.
    Kohli, D. V.
    Chaturvedi, S. C.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2010, 4 (02): : 238 - 241
  • [46] Simultaneous Estimation of Ofloxacin and Ketorolac Tromethamine in Ophthalmic Dosage Form by Reverse Phase High Performance Liquid Chromatography
    Fegade, J. D.
    Bhole, R. P.
    Chaudhari, R. Y.
    Patil, V. R.
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (05) : 3360 - 3366
  • [47] Determination of coenzyme Q10 in human breast milk high-performance liquid chromatography
    Tang, Peter H.
    Miles, Michael V.
    Steele, Paul
    Davidson, Barbara S.
    Geraghty, Sheela R.
    Morrow, Ardythe L.
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (12) : 1336 - 1343
  • [48] Rapid determination of coenzyme Q10 in cheese using high-performance liquid chromatography
    Manzi, Pamela
    Durazzo, Alessandra
    DAIRY SCIENCE & TECHNOLOGY, 2015, 95 (04) : 533 - 539
  • [49] Development and Validation of Stability-indicating High- Performance Liquid Chromatography Method for estimation of organic impurities of Carvedilol from bulk and its Dosage Form
    Desai, M. M.
    Nikalje, Anna Pratima G.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 85 (04) : 962 - 971
  • [50] ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY (UPLC) METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF L-ALANYL-L-GLUTAMINE IN PHARMACEUTICAL DOSAGE FORM (INFUSIONS).
    Wadia, Devang. N.
    Desai, Hemant. T.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2012, 2 (01): : P179 - P184