Subnormothermic machine perfusion protects against rat liver preservation injury: A comparative evaluation with conventional cold storage

被引:30
|
作者
Vairetti, M.
Ferrigno, A.
Rizzo, V.
Richelmi, P.
Boncompagni, E.
Neri, D.
Freitas, I.
Cillo, U.
机构
[1] Univ Pavia, Dept Internal Med & Therapeut, I-27100 Pavia, Italy
[2] IRCCS, Policlin San Matteo, San Matteo, Italy
[3] Univ Padua, Dept Gen Surg 1, Padua, Italy
关键词
D O I
10.1016/j.transproceed.2007.06.002
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Hypothermic machine perfusion (MP) of the liver has been reported to improve graft function reclaiming marginal livers, such as those from non-heart-beating donors. Livers from obese donors often have fatty infiltrates and are more susceptible to hypothermic conditions. No data exist about MP at temperatures > 4 degrees C. This study evaluated liver function after organ preservation by comparing MP at 20 degrees C with conventional cold storage. Methods. For MP, rat livers were perfused for 6 hours using an oxygenated Krebs-Henseleit (KH) solution at 20 degrees C (pH 7.4). For cold storage, livers were perfused in situ and preserved with Celsior solution at 4 degrees C for 6 hours. The reperfusion period with KH (2 hours at 37 degrees C) was performed under the same conditions both among livers preserved by MP or cold storage. Hepatic enzyme release (aspartate aminotransferase [AST], alanine aminotransferase [ALT], lactate dehydrogenase [LDH], and gamma-glutamyl transferase [GGT]), bile production, and ATP levels were measured during MP and reperfusion. Results. At the end of reperfusion, livers preserved by MP showed significantly decreased liver damage compared with cold storage: AST, 18 +/- 4 vs. 45 +/- 6 mU/mL (P <.01); ALT, 1.5 +/- 07 vs. 6 +/- 0.5 mU/mL (P <.01); and LDH, 82 2 vs. 135 29 mU/mL (P <.05). No difference was observed between bile production between MP and cold storage. High levels of biliary GGT and LDH were found in cold preserved livers. ATP levels were higher in livers preserved with MP compared with those preserved by cold storage. Conclusions. MP at 20 degrees C resulted in a better quality of liver preservation, improving hepatocyte survival, compared with conventional cold storage. This may provide a new method for successful utilization of marginal livers, in particular fatty livers.
引用
收藏
页码:1765 / 1767
页数:3
相关论文
共 50 条
  • [31] PRESERVATION OF CADAVERIC KIDNEYS - COLD-STORAGE OR MACHINE PERFUSION
    VANDERVLIET, JA
    VROEMEN, JPAM
    COHEN, B
    LANSBERGEN, Q
    KOOTSTRA, G
    ARCHIVES OF SURGERY, 1983, 118 (10) : 1166 - 1168
  • [32] Preservation of steatotic livers: A comparison between cold storage and machine perfusion preservation
    Bessems, Maud
    Doorschodt, Benedict M.
    Kolkert, Joe L. P.
    Vetelainen, Reeta L.
    van Vliet, Arlene K.
    Vreeling, Heleen
    van Marle, Jan
    van Gulik, Thomas M.
    LIVER TRANSPLANTATION, 2007, 13 (04) : 497 - 504
  • [33] COMBINED COLD-STORAGE AND PERFUSION PRESERVATION OF THE CANINE LIVER
    VANGULIK, TM
    LINDELL, SL
    BOUDJEMA, K
    PIENAAR, BH
    VREUGDENHIL, PK
    SOUTHARD, JH
    BELZER, FO
    TRANSPLANTATION PROCEEDINGS, 1990, 22 (02) : 520 - 522
  • [34] Advantages of normothermic perfusion over cold storage in liver preservation
    Imber, CJ
    St Peter, SD
    de Cenarruzabeitia, IL
    Pigott, D
    James, T
    Taylor, R
    McGuire, J
    Hughes, D
    Butler, A
    Rees, M
    Friend, PJ
    TRANSPLANTATION, 2002, 73 (05) : 701 - 709
  • [35] Machine perfusion under subnormothermic conditions with a new oxygen-carrier solution: the future of liver preservation
    Fontes, Paulo A.
    Marsh, Wallis
    Scott, Victor L.
    Lopez, Roberto
    Soltys, Kyle A.
    van der Plaats, Arian
    Light, William R.
    Damian, Daniela
    Cruz, Ruy J.
    Venkatmaran, Raman
    Shiva, Sruti
    Minervini, Marta I.
    Demetris, Anthony J.
    HEPATOLOGY, 2012, 56 (06) : 1524 - 1524
  • [36] Impact of Subnormothermic Machine Perfusion Preservation in Severely Steatotic Rat Livers: A Detailed Assessment in an Isolated Setting
    Okamura, Y.
    Hata, K.
    Tanaka, H.
    Hirao, H.
    Kubota, T.
    Inamoto, O.
    Kageyama, S.
    Tamaki, I.
    Yermek, N.
    Yoshikawa, J.
    Uemoto, S.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2017, 17 (05) : 1204 - 1215
  • [37] MACHINE PERFUSION VERSUS COLD STORAGE FOR PRESERVATION OF KIDNEYS BEFORE TRANSPLANTATION
    SLOOFF, MJH
    VANDERWIJK, J
    RIJKMANS, BG
    KOOTSTRA, G
    ARCHIVUM CHIRURGICUM NEERLANDICUM, 1978, 30 (02): : 83 - 90
  • [38] Ex-Vivo Perfusion with UW Cold Storage Solution Improves DCD Rat Liver Preservation
    Fyffe-Freil, R.
    Wickramaratne, N.
    Khoraki, J.
    Kang, H.
    Chmielewski, C.
    Li, R.
    Mangino, M. J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2020, 20 : 733 - 734
  • [39] An In Vivo Autotransplant Model of Renal Preservation: Cold Storage Versus Machine Perfusion in the Prevention of Ischemia/Reperfusion Injury
    La Manna, Gaetano
    Conte, Diletta
    Cappuccilli, Maria Laura
    Nardo, Bruno
    D'Addio, Francesca
    Puviani, Lorenza
    Comai, Giorgia
    Bianchi, Francesca
    Bertelli, Riccardo
    Lanci, Nicole
    Donati, Gabriele
    Scolari, Maria Piera
    Faenza, Alessandro
    Stefoni, Sergio
    ARTIFICIAL ORGANS, 2009, 33 (07) : 565 - 569
  • [40] Subnormothermic Ex Vivo Liver Perfusion Is a Safe Alternative to Cold Static Storage for Preserving Standard Criteria Grafts
    Spetzler, Vinzent N.
    Goldaracena, Nicolas
    Echiverri, Juan
    Kaths, J. Moritz
    Louis, Kristine S.
    Adeyi, Oyedele A.
    Yip, Paul M.
    Grant, David R.
    Selzner, Nazia
    Selzner, Markus
    LIVER TRANSPLANTATION, 2016, 22 (01) : 111 - 119