Energy resolution and energy-light response of CsI(Tl) scintillators for charged particle detection

被引:46
|
作者
Wagner, A
Tan, WP
Chalut, K
Charity, RJ
Davin, B
Larochelle, Y
Lennek, MD
Liu, TX
Liu, XD
Lynch, WG
Ramos, AM
Shomin, R
Sobotka, LG
de Souza, RT
Tsang, MB
Verde, G [1 ]
Xu, HS
机构
[1] Michigan State Univ, NSCL, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Phys & Astron, E Lansing, MI 48824 USA
[3] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[4] Indiana Univ, IUCF, Bloomington, IN 47405 USA
[5] Washington Univ, Dept Chem, St Louis, MO 63130 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2001年 / 456卷 / 03期
基金
美国国家科学基金会;
关键词
charged particle spectroscopy; Cs (Tl) scintillation detectors; non-uniformity of light output; energy-light response;
D O I
10.1016/S0168-9002(00)00542-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article describes the crystal selection and quality control utilized to develop and calibrate a high-resolution array of CsI(T1) scintillator crystals for the detection of energetic charged particles. Alpha sources are used to test the light output variation due to thallium doping gradients. Selection of crystals with better than 1% non-uniformity in light output is accomplished using this method. Tests with a 240 MeV alpha beam reveal that local light output variations within each of the tested CsI(T1) crystals limit the resolution to about 0.5%. Charge and mass dependences in the energy-light output relationship are determined by calibrating with energetic projectile fragmentation beams. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:290 / 299
页数:10
相关论文
共 50 条
  • [41] Systematics in the light response of BGO, CsI(T1) and GSO(Ce) scintillators to charged particles
    Avdeichikov, V
    Jakobsson, B
    Nikitin, VA
    Nomokonov, PV
    Wegner, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 251 - 258
  • [42] LIGHT OUTPUT AND ENERGY RESOLUTION OF BGO AND GSO SCINTILLATORS FOR LIGHT-IONS
    AVDEICHIKOV, VV
    BERGHOLT, L
    GUTTORMSEN, M
    TAYLOR, JE
    WESTERBERG, L
    WHITLOW, HJ
    BORDENKO, YA
    BURACHAS, SF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 381 - 384
  • [43] USING THE COMBINATION CSI(TL) AND PHOTODIODE FOR IDENTIFICATION AND ENERGY MEASUREMENT OF LIGHT PARTICLES
    GUINET, D
    CHAMBON, B
    CHEYNIS, B
    DEMEYER, A
    DRAIN, D
    HU, XC
    PASTOR, C
    VAGNERON, L
    ZAID, K
    GIORNI, A
    HEUER, D
    LLERES, A
    VIANO, JB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02): : 614 - 616
  • [44] Two annular CsI(Tl) detector arrays for the charged particle telescopes
    Hong-Yu Zhu
    Jian-Ling Lou
    Yan-Lin Ye
    Li-Sheng Yang
    Bo-Long Xia
    Kang Wei
    Ying Chen
    Wei-Liang Pu
    Zi-Yao Hu
    Hao-Yu Ge
    Jia-Hao Chen
    Kai Ma
    Wen-Wu Wan
    Hooi-Jin Ong
    Yan-Yun Yang
    Shi-Wei Xu
    Kang Wang
    Fang-Fang Duan
    Jun-Bin Ma
    Zhen Bai
    Peng Ma
    Ruo-Fu Chen
    NuclearScienceandTechniques, 2023, 34 (10) : 160 - 167
  • [45] Two annular CsI(Tl) detector arrays for the charged particle telescopes
    Zhu, Hong-Yu
    Lou, Jian-Ling
    Ye, Yan-Lin
    Yang, Li-Sheng
    Xia, Bo-Long
    Wei, Kang
    Chen, Ying
    Pu, Wei-Liang
    Hu, Zi-Yao
    Ge, Hao-Yu
    Chen, Jia-Hao
    Ma, Kai
    Wan, Wen-Wu
    Ong, Hooi-Jin
    Yang, Yan-Yun
    Xu, Shi-Wei
    Wang, Kang
    Duan, Fang-Fang
    Ma, Jun-Bin
    Bai, Zhen
    Ma, Peng
    Chen, Ruo-Fu
    NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (10)
  • [46] Two annular CsI(Tl) detector arrays for the charged particle telescopes
    Hong-Yu Zhu
    Jian-Ling Lou
    Yan-Lin Ye
    Li-Sheng Yang
    Bo-Long Xia
    Kang Wei
    Ying Chen
    Wei-Liang Pu
    Zi-Yao Hu
    Hao-Yu Ge
    Jia-Hao Chen
    Kai Ma
    Wen-Wu Wan
    Hooi-Jin Ong
    Yan-Yun Yang
    Shi-Wei Xu
    Kang Wang
    Fang-Fang Duan
    Jun-Bin Ma
    Zhen Bai
    Peng Ma
    Ruo-Fu Chen
    Nuclear Science and Techniques, 2023, 34
  • [47] Large volume CsI(Tl) scintillators for exotic particle search in 90Zr
    Kobayashi, S
    Tsuchiyama, H
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 850 - 854
  • [48] Impact of precursor purity on optical properties and radiation detection of CsI:Tl scintillators
    Phannee Saengkaew
    Sakuntam Sanorpim
    Manit Jitpukdee
    Kulthawat Cheewajaroen
    Chadet Yenchai
    Decho Thong-aram
    Visittapong Yordsri
    Chanchana Thanachayanont
    Noppadon Nuntawong
    Applied Physics A, 2016, 122
  • [49] THE RESPONSE OF A LARGE CSI(TL) DETECTOR TO LIGHT PARTICLES AND HEAVY-IONS IN THE INTERMEDIATE-ENERGY RANGE
    FOMICHEV, AS
    DAVID, I
    LUKYANOV, SM
    PENIONZHKEVICH, YE
    SKOBELEV, NK
    TARASOV, OB
    MATTHIES, A
    ORTLEPP, HG
    WAGNER, W
    LEWITOWICZ, M
    STLAURENT, MG
    CORRE, JM
    DLOUHY, Z
    PECINA, I
    BORCEA, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (02): : 378 - 383
  • [50] Impact of precursor purity on optical properties and radiation detection of CsI:Tl scintillators
    Saengkaew, Phannee
    Sanorpim, Sakuntam
    Jitpukdee, Manit
    Cheewajaroen, Kulthawat
    Yenchai, Chadet
    Thong-aram, Decho
    Yordsri, Visittapong
    Thanachayanont, Chanchana
    Nuntawong, Noppadon
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2016, 122 (08):