The flow-field pattern Optimization of the Bipolar Plate for PEMFC Considering the Nonlinear Material

被引:0
|
作者
Choi, Kap-Seung [1 ]
机构
[1] Tongmyong Univ, Dept Automot Engn, Busan 608711, South Korea
来源
关键词
PEMFC(proton exchange membrane fuel cell); Serpentine flow-field design; Optimization; Current density distribution; FSI(Fluid-Structure Interaction); FSI Method; MEMBRANE FUEL-CELL; GAS-DIFFUSION LAYER; ASSEMBLY PRESSURE; PERFORMANCE; MODEL;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
During the assembly of a fuel cell, the mechanical stress and strain that occur have a significantly large effect on the performance and reliability of fuel cell. When assembling a fuel cell stack, the assembly pressure generated can decrease the interfacial contact resistance (ICR) between the bipolar plate (BPP), gas diffusion layer (GDL) and catalyst layer, and also, the reduction in mass transfer that happens during the electrochemical reaction in the catalyst layer through the GDL must be considered. Recent research on the numerical analysis of fuel cells does not take into account the aforementioned importance of the GDL compression deformation, claiming the restrictions of numerical analysis, and uses a simple model to analyze the mass transfer of the fuel cells using CFD analysis. Therefore in this research, the performance of the fuel cell (e.g. pressure drop, gas permeability of GDL, and the electrolyte membrane water content (lambda) were compared for the FSI model, which is a thermal fluid based PEMFC model (CFD model) that takes the GDL compression deformation into account. The GDL compression deformation, dependent on the fuel cell assembly pressure, affects the gas permeability caused by under-rib convection. As a result in the inlet of the fuel cell, the internal pressure and flow velocity increase due to the decrease in cross sectional area, but due to the decreased gas permeability of the rib it has a low current density, and as the outlet is approached, it can be determined that the current density actually increases due to the hydrogen and oxygen mass fractions being greater than the CFD model making the current density more uniform overall. Therefore using the FSI analysis method, it is important to predict the optimized fuel cell architecture and operating condition parameters.
引用
收藏
页码:2564 / 2579
页数:16
相关论文
共 50 条
  • [21] Computational evaluation of PEMFC performance based on bipolar plate material types
    Musse, Dawit
    Lee, Dongkyoung
    ENERGY REPORTS, 2024, 11 : 4886 - 4903
  • [22] Performance Analysis of a Direct Methanol Fuel Cell Stack With Bipolar Plate Incorporated With Innovative Flow-Field Combination
    Shen, Chia-Chieh
    Jung, Guo-Bin
    Weng, Feng-Bor
    Yeh, Chia-Chen
    Lee, Chih-Hung
    Su, Yi-Ju
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2014, 11 (03):
  • [23] Topology optimization of distribution and collection zones for flow field plate of large-scale PEMFC
    Xiao, Congda
    Tian, Shaopeng
    Guo, Hui
    Wang, Long
    Pan, Yuxin
    Yang, Shujin
    Xie, Wenlong
    FUEL, 2025, 382
  • [24] The impact of flow field pattern on concentration and performance in PEMFC
    Su, A
    Chiu, YC
    Weng, FB
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (05) : 409 - 425
  • [25] Investigation of bifurcation structure flow field for bipolar plates in PEMFC
    Chen, Tao
    Gong, Shi-Chao
    Xiao, Yong
    HEAT AND MASS TRANSFER, 2013, 49 (02) : 147 - 153
  • [26] Investigation of bifurcation structure flow field for bipolar plates in PEMFC
    Tao Chen
    Shi-Chao Gong
    Yong Xiao
    Heat and Mass Transfer, 2013, 49 : 147 - 153
  • [27] Flow Field Model Experiment Studies of a Bipolar Plates PEMFC
    Jiang, Bingkun
    Ji, Xinjie
    Li, Yongzhong
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 581 - 584
  • [28] AN EXPERIMENTAL INVESTIGATION OF AIR WATER FLOW THROUGH DIFFERENT FLOW FIELD DESIGNS OF A PEMFC BIPOLAR PLATE IN THE PRESENCE OF MICRONIZED WAX
    Utturkar, Aditya
    Mukherjee, Abhijit
    PROCEEDINGS OF THE ASME 9TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY 2011, 2012, : 613 - 621
  • [29] Comparison between CFD Analysis and Experiments According to Various PEMFC Flow-field Designs
    Lee, Kang In
    Lee, Se Won
    Park, Min Soo
    Cho, Yong-Hun
    Cho, Yoon-Hwan
    Chu, Chong Nam
    Sung, Yung-Eun
    JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY, 2009, 12 (01): : 61 - 67
  • [30] Effect of channel length on interdigitated flow-field PEMFC performance: A computational and experimental study
    Santamaria, Anthony D.
    Cooper, Nathanial J.
    Becton, Maxwell K.
    Park, Jae Wan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (36) : 16253 - 16263