Improving the chemiluminescence-based determination of sulphide in complex environmental samples by using a new, automated multi-syringe flow injection analysis system coupled to a gas diffusion unit

被引:64
|
作者
Maya, Fernando [1 ]
Estela, Jose Manuel [1 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Fac Sci, Dept Chem, E-07122 Palma de Mallorca, Spain
关键词
multi-syringe flow injection analysis; gas diffusion; chemiluminescence detection; luminol; sulphide; environmental samples;
D O I
10.1016/j.aca.2007.08.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, completely automated multi-syringe flow injection analysis (MSFIA) system coupled to a gas diffusion unit (GDU) was used for the chemiluminescence (CL)-based determination of sulphide ion in various types of environmental matrices with a high sensitivity and selectivity, and the need for no manual sample pretreatment. Sulphide ions are transferred as H(2)S from the donor channel of the GDU to its acceptor channel (AC) through a hydrophobic membrane inserted between the two streams. The solution held in AC replaces the initial sample matrix, which may contain a wide variety of interferents, with one suitable for the CL determination of the analyte. once sulphide ions have been isolated from the sample matrix, they are determined by their catalytic action on the lumino/H(2)O(2) chemiluminescent reaction system. The influence of various chemical and hydrodynamic variables is discussed and the performance of the proposed system compared with that of existing flow systems for the same purpose. Under the operating conditions used, the proposed method features a linear working range of 0.02-2 mg L(-1), a limit of detection (3 sigma(blank)) of 0.003 mg L(-1), a throughput of 20 samples h(-1) and a coefficient of variation of 2.4% (n = 10) for a 1 mgL(-1) sulphide concentration. The method was used to determine sulphide in leachates and various types of water samples. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 7 条
  • [1] Expert multi-syringe flow-injection system for the determination and speciation analysis of iron using chelating disks in water samples
    Pons, C
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) : 79 - 88
  • [2] The use of anion-exchange disks in an optrode coupled to a multi-syringe flow-injection system for the determination and speciation analysis of iron in natural water samples
    Pons, C
    Forteza, R
    Cerdà, V
    TALANTA, 2005, 66 (01) : 210 - 217
  • [3] Spectrophotometric determination of zinc and copper in a multi-syringe flow injection analysis system using a liquid waveguide capillary cell: Application to natural waters
    Pascoa, Ricardo N. M. J.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    TALANTA, 2011, 84 (05) : 1267 - 1272
  • [4] Spectrophotometric determination of bromide in water using the multisyringe flow injection analysis technique coupled to a gas-diffusion unit
    Danchana, Kaewta
    Maya, Fernando
    Wilairat, Prapin
    Uraisin, Kanchana
    Cerda, Victor
    ANALYTICAL METHODS, 2015, 7 (10) : 4202 - 4208
  • [5] A robust multi-syringe system for process flow analysis.: Part 3.: Time based injection applied to the spectrophotometric determination of nickel(II) and iron speciation
    Albertús, F
    Cladera, A
    Becerra, E
    Cerdà, V
    ANALYST, 2001, 126 (06) : 903 - 910
  • [6] An automatic chemiluminescence method based on the multi-pumping flow system coupled with the fluidized reactor and direct-injection detector: Determination of uric acid in saliva samples
    Vakh, Christina
    Koronkiewicz, Stanislawa
    Kalinowski, Slawomir
    Moskvin, Leonid
    Bulatov, Andrey
    TALANTA, 2017, 167 : 725 - 732
  • [7] POTENTIOMETRIC DETERMINATION OF ETHANOL IN ALCOHOLIC BEVERAGES USING A FLOW-INJECTION ANALYSIS SYSTEM EQUIPPED WITH A GAS-DIFFUSION UNIT WITH A MICROPOROUS POLY(TETRAFLUOROETHYLENE) MEMBRANE
    OHURA, H
    IMATO, T
    ASANO, Y
    YAMASAKI, S
    ISHIBASHI, N
    ANALYTICAL SCIENCES, 1990, 6 (04) : 541 - 545