Expert multi-syringe flow-injection system for the determination and speciation analysis of iron using chelating disks in water samples

被引:34
|
作者
Pons, C [1 ]
Forteza, R [1 ]
Cerdà, V [1 ]
机构
[1] Univ Balearic Isl, Fac Sci, Dept Chem, E-07122 Palma de Mallorca, Spain
关键词
multi-syringe flow-injection analysis; expert system; chelating disk; pre-concentration; speciation analysis;
D O I
10.1016/j.aca.2004.01.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel expert multi-syringe flow-injection system has been developed. This system, which is able to choose for itself the best strategy to quantify the analyte, has been applied to the spectrophotometric determination, pre-concentration and speciation analysis of iron. The determination of the lowest iron concentrations benefits from the retention of the analyte on a chelating disk (iminodiacetic acid groups) which has been placed in a laboratory-made methyl methacrylate cylindrical device. A three-way solenoid commutation valve allows the deviation of the flow towards the chelating disk to follow the pre-concentration schemes when necessary. Ammonium thiocyanate was used as the chromogenic reagent for iron(III). Total iron can be determined by on-line oxidation of iron(II) to iron(III) with a hydrogen peroxide stream. A mass calibration was feasible in the wide range from 0.019 to 3 mug. The detection limit (3(sb)/S) was 19 ng. The repeatability (RSD), calculated from 11 replicates using 3 ml injections of a 0.5 mg 1(-1), was 2%. When pre-concentration was not required, two linear calibration graph between 0.1 and 20 mg 1(-1) and between 0.2 and 35 mg 1(-1) for the determination of iron(III) and total iron, respectively, were obtained. The proposed technique has been validated by replicate analysis (n = 3) of a certified reference material of water with satisfactory results. The use of chelating disks offers several advantages over the conventional resin. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 50 条
  • [1] The use of anion-exchange disks in an optrode coupled to a multi-syringe flow-injection system for the determination and speciation analysis of iron in natural water samples
    Pons, C
    Forteza, R
    Cerdà, V
    TALANTA, 2005, 66 (01) : 210 - 217
  • [2] Multi-syringe flow injection system for the determination of available phosphorus in soil samples
    Almeida, MIGS
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2005, 85 (01) : 51 - 62
  • [3] Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system
    Gomes, DMC
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    TALANTA, 2005, 66 (03) : 703 - 711
  • [4] Direct Introduction of Slurry Samples in Multi-syringe Flow Injection Analysis: Determination of Potassium in Plant Samples
    M. Inês G. S. Almeida
    Marcela A. Segundo
    José L. F. C. Lima
    António O. S. S. Rangel
    Analytical Sciences, 2008, 24 : 601 - 606
  • [5] Direct introduction of slurry samples in multi-syringe flow injection analysis: Determination of potassium in plant samples
    Almeida, M. Ines G. S.
    Segundo, Marcela A.
    Lima, Jose L. F. C.
    Rangel, Antonio O. S. S.
    ANALYTICAL SCIENCES, 2008, 24 (05) : 601 - 606
  • [6] Multi-syringe flow-injection systems improve antioxidant assessment
    Magalhaes, Luis M.
    Ribeiro, Joana P. N.
    Segundo, Marcela A.
    Reis, Salette
    Lima, Jose L. F. C.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (08) : 952 - 960
  • [7] A multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistries
    Pascoa, Ricardo N. M. J.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    MICROCHEMICAL JOURNAL, 2009, 93 (02) : 153 - 158
  • [8] Multi-syringe flow injection system with in-line microwave digestion for the determination of phosphorus
    Almeida, MIGS
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    TALANTA, 2004, 64 (05) : 1283 - 1289
  • [9] A robust multi-syringe system for process flow analysis.: Part 3.: Time based injection applied to the spectrophotometric determination of nickel(II) and iron speciation
    Albertús, F
    Cladera, A
    Becerra, E
    Cerdà, V
    ANALYST, 2001, 126 (06) : 903 - 910
  • [10] A portable multi-syringe flow system for spectrofluorimetric determination of iodide in seawater
    Frizzarin, Rejane M.
    Aguado, Enrique
    Portugal, Lindomar A.
    Moreno, Daniel
    Estela, Jose M.
    Rocha, Fabio R. P.
    Cerda, Victor
    TALANTA, 2015, 144 : 1155 - 1162