Simulation and Experiment Analysis of 10 kV Flexible Grounding Device

被引:3
|
作者
Liu, Mengxuan [1 ]
Zhang, Chi [1 ]
Liu, Kangli [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
关键词
flexible grounding; single-phase grounding fault; control system; current compensation; fault detection; line protection; FAULT ARC-SUPPRESSION; SINGLE-PHASE; PROTECTION; PRINCIPLE;
D O I
10.3390/info12090384
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The traditional 10 kV distribution network grounding system has some disadvantages, such as small grounding current and poor arc extinguishing effect, thus, hindering the detection of high-resistance grounding fault. Therefore, this paper studied the flexible grounding system consisting of small-resistance and active inverter in parallel. The control system comprises the compensation current calculation module, the fault detection module, and line protection strategy. During a single-phase grounding fault, the device is designed to inject a current of a given amplitude and phase into the neutral point to effectively suppress fault-point voltage and current and, meanwhile, quickly identifying the fault line or the busbar fault and then systematically protecting the distribution line. In addition, a large number of simulations have performed based on three grounding faults (metal, low-resistance, and high-resistance) and two modes (ungrounded and small-resistance grounding). The device can all be functional. Finally, a 400 V-level experimental prototype was built, and the experimental results are consistent with the simulation results, which can verify the effectiveness and feasibility of the flexible grounding device.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] The choice of the method of neutral grounding in 6-10 kv power networks
    Yevdokunin, GA
    Gudilin, SV
    Korepanov, AA
    ELECTRICAL TECHNOLOGY RUSSIA, 1998, (04): : 104 - 127
  • [32] Simulation analysis and experimental research of 10 kV multiple-chamber arc-extinguishing lightning protection device with strong airflow
    Wang J.
    Wu D.
    Liang X.
    Li G.
    Wang X.
    Wu, Dong (274573302@qq.com), 2016, Science Press (42): : 1497 - 1502
  • [33] A method of phase selection and line selection for grounding faults in an asymmetric distribution network based on a flexible-grounding device
    Chen B.
    Yu K.
    Zeng X.
    Li L.
    Xu P.
    Peng H.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (12): : 1 - 10
  • [34] Simulation and experiment on a flexible control method for ferroresonance
    Sima, Wenxia
    Yang, Ming
    Yang, Qing
    Yuan, Tao
    Zou, Mi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (10) : 1744 - 1753
  • [35] Rigid-flexible coupling simulation and analysis of crawler excavator working device
    Liu, Zhenguang
    Sun, Beibei
    Zhang, Jianrun
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2013, 33 (SUPPL.1): : 37 - 40
  • [36] Analysis and simulation on intermittent arc grounding overvoltage for neutral grounding via arc-suppression coil with shunt resistance in 35 kV urban distribution system
    Qiao, Zhanjun
    International Journal of Signal Processing, Image Processing and Pattern Recognition, 2014, 7 (05) : 37 - 46
  • [37] Selection of Terminal Device for Virtual Simulation Experiment
    Fuan, Wen
    Gang, Cao
    2020 5TH INTERNATIONAL STEM EDUCATION CONFERENCE (ISTEM-ED), 2020,
  • [38] Optimal Injection Current Calculation and Implementation of Flexible Grounding Device for Suppressing Ferromagnetic Resonance
    Lu P.
    Wang W.
    Liu P.
    Liu Q.
    Zeng X.
    Li J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (04): : 1438 - 1448
  • [39] Universal Switch for Measuring the Resistance of the Grounding Device Supports of the 110 kV Overhead Power Line
    Borodin, M., V
    Belikov, R. P.
    Lysenko, N. E.
    Shabanov, I., V
    Safin, A. R.
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (08) : 1528 - 1536
  • [40] Experimental study on grounding characteristics of reinforced concrete poles for 10 kV distribution lines
    Shen, H. (shenhb@epri.sgcc.com.cn), 1670, Power System Technology Press (38):