Investigation of the gas hold-up of oxygen and hydrogen in different aqueous electrolyte solutions .2. Modelling of the gas hold-up

被引:0
|
作者
Kellermann, H [1 ]
Juttner, KM [1 ]
Kreysa, G [1 ]
机构
[1] DECHEMA EV,KARL WINNACKER INST,D-60486 FRANKFURT,GERMANY
来源
CHEMISCHE TECHNIK | 1996年 / 48卷 / 03期
关键词
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To date models used to describe the gas hold-up in a homogeneous bubble flow have not considered the coalescence behaviour of the gas bubbles. in several studies, however, it is shown that coalescence has a strong effect on gas hold-up. Using the results of experimental investigations, a new model was developed to calculate the gas hold-up in different electrolyte solutions. The coalescence in this model is considered as a reaction of two bubbles. The reaction rate constant of the coalescence reaction is the main parameter for predicting the gas hold-vp for different solutions and gases. It not only depends on the type and concentration of the electrolyte, but also on the kind of gas.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 50 条
  • [41] Ways of Estimating the Hold-up Time of a Gas Chromatographic System
    Shiryaeva, V. E.
    Popova, T. P.
    Kanat'eva, A. Yu
    Korolev, A. A.
    Kurganov, A. A.
    [J]. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2019, 93 (11) : 2291 - 2296
  • [42] Gas hold-up profiles in foaming liquids in bubble columns
    [J]. Joshi, J.B. (jbj@udct.ernet.in), 1600, (Elsevier):
  • [43] GAS HOLD-UP IN EXTERNAL-LOOP AIRLIFT BIOREACTORS
    KAWASE, Y
    TSUJIMURA, M
    YAMAGUCHI, T
    [J]. BIOPROCESS ENGINEERING, 1995, 12 (1-2): : 21 - 27
  • [44] Influence of particles and electrolyte on gas hold-up and mass transfer in a slurry bubble column
    Ruthiya, KC
    van der Schaaf, J
    Kuster, BFM
    Schouten, JC
    [J]. INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2006, 4
  • [45] Fractional gas hold-up in gas inducing type of mechanically agitated contactors
    Saravanan, K
    Joshi, JB
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1996, 74 (01): : 16 - 30
  • [46] On the gas expansion and gas hold-up in vertical slugging columns - A simulation study
    Mayor, T. S.
    Pinto, A. M. F. R.
    Campos, J. B. L. M.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (05) : 799 - 815
  • [47] THE EFFECT OF VESSEL SCALE ON GAS HOLD-UP IN GAS-LIQUID SYSTEMS
    Cudak, Magdalena
    [J]. CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2020, 41 (04): : 241 - 256
  • [48] GAS HOLD-UP IN NON-NEWTONIAN SOLUTIONS IN A BUBBLE-COLUMN WITH INTERNALS
    PRADHAN, AK
    PARICHHA, RK
    DE, P
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1993, 71 (03): : 468 - 471
  • [49] PRESSURE-DROP, GAS HOLD-UP, AND OXYGEN-TRANSFER IN TOWER SYSTEMS
    HSU, KH
    ERICKSON, LE
    FAN, LT
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1977, 19 (02) : 247 - 265
  • [50] Effect of water conductivity on gas hold-up and oxygen transfer rate in an electroflotation column
    Hajlaoui, Nadia
    Kotti, Mariam
    Ksentini, Issam
    Ben Mansour, Lassaad
    [J]. DESALINATION AND WATER TREATMENT, 2017, 98 : 176 - 181