Simple and rapid analysis of endocrine disruptors in liquid medicines and intravenous injection solutions by automated in-tube solid-phase microextraction/high performance liquid chromatography

被引:56
|
作者
Mitani, K
Narimatsu, S
Izushi, F
Kataoka, H [1 ]
机构
[1] Shujitsu Univ, Sch Pharm, Okayama 7038516, Japan
[2] Okayama Univ, Fac Pharmaceut Sci, Okayama 7008530, Japan
[3] Okayama Red Cross Gen Hosp, Okayama 7008607, Japan
关键词
in-tube solid-phase microextraction; intravenous injection solutions; automated sample preparation; endocrine disrupting compound; phthalates;
D O I
10.1016/S0731-7085(03)00221-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid method was developed for analyzing contamination of endocrine disruptors in liquid medicines and intravenous injection solutions. Endocrine disrupting compounds such as bisphenol A (BPA), alkylphenols and phthalates were quantitated by on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography (in-tube SPME/HPLC) with UV detection. The liquid medicines and intravenous injection solutions could be used directly without any pretreatment, and the BPA, alkylphenols and phthalates in these solutions were automatically analyzed. The limits of quantification for these compounds were 1-10 ng/ml. Recoveries of these compounds spiked to the intravenous injection solutions was over 80%, except for some phthalates. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/mi in most intravenous injection solutions in plastic containers, but it was not detected in solutions in glass bottles. Diethyl phthalate, di-n-propyl phthalate, DBP and di-2-ethylhexyl phthalate (DEHP) were also detected in syrup, lotion and eye drops. in plastic containers. On the other hand, BPA and alkylphenols were not-detected at all in these solutions. DEHP contamination from an administration set increased when total vitamin formulation was added to the infusion solution. DEHP was easily leached from polyvinyl chloride tubing by polysorbate 80. The in-tube SPME/HPLC method is simple, rapid and automatic, and it provides a useful tool for the screening, and determination of endocrine disruptor. contamination in liquid medicines and intravenous injection solutions. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:469 / 478
页数:10
相关论文
共 50 条
  • [41] Development of in-tube solid-phase microextraction/liquid chromatography/electrospray ionization mass spectrometry for the analysis of mutagenic heterocyclic amines
    Kataoka, H
    Pawliszyn, J
    CHROMATOGRAPHIA, 1999, 50 (9-10) : 532 - 538
  • [42] In-tube solid-phase microextraction with molecularly imprinted polymer to determine interferon alpha 2a in plasma sample by high performance liquid chromatography
    Chaves, Andrea Rodrigues
    Costa Queiroz, Maria Eugenia
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1318 : 43 - 48
  • [43] Hybrid organic-inorganic octyl monolithic column for in-tube solid-phase microextraction coupled to capillary high-performance liquid chromatography
    Zheng, Ming-Ming
    Lin, Bo
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) : 48 - 55
  • [44] Detection of trans-fatty acids by high performance liquid chromatography coupled with in-tube solid-phase microextraction using hydrophobic polymeric monolith
    Wu, Fangling
    Wang, Jiabin
    Zhao, Qi
    Jiang, Nan
    Lin, Xucong
    Xie, Zenghong
    Li, Jianhua
    Zhang, Qiqing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1040 : 214 - 221
  • [45] Simultaneous residue monitoring of four tetracycline antibiotics in fish muscle by in-tube solid-phase microextraction coupled with high-performance liquid chromatography
    Wen, Yi
    Wang, Ying
    Feng, Yu-Qi
    TALANTA, 2006, 70 (01) : 153 - 159
  • [46] Determination of aflatoxins in food samples by automated on-line in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry
    Nonaka, Y.
    Saito, K.
    Hanioka, N.
    Narimatsu, S.
    Kataoka, H.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (20) : 4416 - 4422
  • [47] SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHEN, J
    PAWLISZYN, JB
    ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2530 - 2533
  • [48] In-loop solid-phase microextraction coupled with high performance liquid chromatography
    Djozan, DJ
    Amir-Zehni, M
    CHROMATOGRAPHIA, 2004, 60 (9-10) : 567 - 572
  • [49] In-Loop Solid-Phase Microextraction Coupled with High Performance Liquid Chromatography
    Dj. Djozan
    M. Amir-Zehni
    Chromatographia, 2004, 60 : 567 - 572
  • [50] An ionic-liquid-modified melamine-formaldehyde aerogel for in-tube solid-phase microextraction of estrogens followed by high performance liquid chromatography with diode array detection
    Feng, Juanjuan
    Wang, Xiuqin
    Han, Sen
    Ji, Xiangping
    Li, Chunying
    Luo, Chuannan
    Sun, Min
    MICROCHIMICA ACTA, 2019, 186 (12)