A high resolving power ion selector for post-source decay measurements in a reflecting time-of-flight mass spectrometer

被引:0
|
作者
Piyadasa, CKG [1 ]
Hakansson, P
Ariyaratne, TR
Barofsky, DF
机构
[1] Univ Colombo, Dept Phys, Colombo 03, Sri Lanka
[2] Angstrom Lab, Div Ion Phys, S-75121 Uppsala, Sweden
[3] Oregon State Univ, Dept Chem, Corvallis, OR 97331 USA
关键词
D O I
10.1002/(SICI)1097-0231(19981130)12:22<1655::AID-RCM383>3.0.CO;2-C
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrostatic deflector has been designed and constructed that can be used in a reflecting time-of-flight mass spectrometer for either single-deflector or dual-deflector velocity selection in post-source decay measurements. The deflector consists of an interleaved set of parallel deflection electrodes as in a Loeb/Cravath/Bradbury device, but thin metal ribbon instead of wire is used for the deflection electrodes. The time for reversing the electric field, which depends on various factors such as the electronics for pulsing the voltage and the time constant of a particular electrode geometry, is about 19 ns for the deflectors used in this study. By properly timing the reversal of the electric field, the time-window for ion transmission can be made substantially less than the switching time of each individual deflector, In conjunction with matrix-assisted laser desorption/ionization, the single-deflector's resolving power and transmission are robust with respect to laser fluence, i.e. they remain high even when the fluence is raised well above threshold, By contrast the operational features of the dual-deflector gate offer more versatility in locating and sizing the selection window, Operating the ion selector in a single-deflector mode, we have achieved a resolving power of similar to 710 full width at half maximum (FWHM) for different isotopes of protonated, sodiated, and potassiated substance-P (m/z 1348.6, 1370.6 and 1386.6 respectively; 10.073 keV), Operating it in the dual-deflector mode under two different sets of conditions, we have succeeded in obtaining resolving powers of similar to 1100 (FWHM) for protonated substance-P (m/z 1348.6; 10.8 keV) and similar to 5200 (FWHM) for an isotopomer of PEG 6000 (similar to m/z 6000; 10.04 keV). This accomplishment implies that high-resolution ion selection can be coupled to post-source decay analyses. (C) 1998 John Wiley & Sons, Ltd.
引用
收藏
页码:1655 / 1664
页数:10
相关论文
共 50 条
  • [1] MEASUREMENTS OF ION DISSOCIATION IN A REFLECTING TIME-OF-FLIGHT MASS-SPECTROMETER
    STANDING, KG
    ENS, W
    MAO, Y
    LAFORTUNE, F
    MAYER, F
    POPPE, N
    SCHUELER, B
    TANG, X
    WESTMORE, JB
    [J]. JOURNAL DE PHYSIQUE, 1989, 50 (C-2): : 163 - 167
  • [2] Orthogonal electron impact source for a time-of-flight mass spectrometer with high mass resolving power
    Chen, YH
    Gonin, M
    Fuhrer, K
    Dodonov, A
    Su, CS
    Wollnik, H
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 185 : 221 - 226
  • [3] Structural analysis of secondary ions by post-source decay in time-of-flight secondary ion mass spectrometry
    Touboul, D
    Brunelle, A
    Laprévote, O
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (04) : 703 - 709
  • [4] RESOLVING POWER AND MEASUREMENT OF ISOTOPIC ABUNDANCES BY A TIME-OF-FLIGHT MASS SPECTROMETER WITH A LASER ION SOURCE
    BYKOVSKII, YA
    DYMOVICH, VI
    KOZYREV, YP
    NEVOLIN, VN
    SILNOV, SM
    [J]. SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1971, 15 (11): : 1877 - +
  • [5] Using a matrix-assisted laser desorption ionization time-of-flight mass spectrometer for combined in-source decay/post-source decay experiments
    Pfeifer, T
    Drewello, M
    Schierhorn, A
    [J]. JOURNAL OF MASS SPECTROMETRY, 1999, 34 (06): : 644 - 650
  • [6] Using a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer for combined in-source decay/post-source decay experiments
    Pfeifer, Thomas
    Drewello, Mario
    Schierhorn, Angelika
    [J]. Journal of Mass Spectrometry, 34 (06): : 644 - 650
  • [7] A comparison of negative and positive ion time-of-flight post-source decay mass spectrometry for peptides containing basic residues
    Clipston, NL
    Jai-nhuknan, J
    Cassady, CJ
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 222 (1-3) : 363 - 381
  • [8] CONTINUOUS ION SOURCE FOR A TIME-OF-FLIGHT MASS SPECTROMETER
    STUDIER, MH
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1963, 34 (12): : 1367 - &
  • [9] SEQUENCING PEPTIDES WITHOUT SCANNING THE REFLECTRON - POST-SOURCE DECAY WITH A CURVED-FIELD REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    CORDERO, MM
    CORNISH, TJ
    COTTER, RJ
    LYS, IA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (14) : 1356 - 1361
  • [10] REFLECTING TIME-OF-FLIGHT MASS-SPECTROMETER WITH AN ELECTROSPRAY ION-SOURCE AND ORTHOGONAL EXTRACTION
    VERENTCHIKOV, AN
    ENS, W
    STANDING, KG
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (01) : 126 - 133