Blood screening nucleic acid amplification tests for human immunodeficiency virus Type 1 may require two different amplification targets

被引:43
|
作者
Chudy, Michael
Weber-Schehl, Marijke
Pichl, Lutz
Jork, Christine
Kress, Julia
Heiden, Margarethe
Funk, Markus B.
Nuebling, C. Micha [1 ]
机构
[1] Paul Ehrlich Inst, D-63225 Langen, Germany
关键词
TRANSMISSION; EXPERIENCE;
D O I
10.1111/j.1537-2995.2011.03281.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Five cases of human immunodeficiency virus Type 1 (HIV-1) RNApositive blood donations are described that escaped detection by three different CE-marked nucleic acid amplification technique (NAT) screening assays. These events were associated with two HIV-1 transmissions to recipients of blood components. The implicated NAT assays are monotarget assays and amplify in different viral genome regions (group-specific antigen or long terminal repeat). Investigations into the cause of the false-negative test results were initiated. STUDY DESIGN AND METHODS: Plasma specimens of the five NAT false-negative cases were comparatively investigated in 12 CE-marked HIV-1 NAT systems of differing design. The relative amplification efficiency for the HIV-1 variant was determined for each assay. Sequencing of the variants in the region targeted by each false-negative NAT assay allowed comparison with the respective primers and probes. RESULTS: Some of the NAT assays designed in a similar way to false-negative monotarget NATs also revealed deficiencies in detecting the viral variants. In each case sequencing of the assay target region in the variants demonstrated mismatches with primers and probes used by the assays. Some dual-target assays showed decreased amplification efficiency, but not false-negative results. CONCLUSION: HIV is characterized by its rapid evolution of new viral variants. The evolution of new sequences is unpredictable; NAT screening assays with a single target region appear to be more vulnerable to sequence variations than dual-target assays. Based on this experience with false-negative tests results by monotarget NAT assays, the Paul-Ehrlich-Institut is considering requesting dual-target NAT assays for HIV-1 blood donation screening in Germany.
引用
收藏
页码:431 / 439
页数:9
相关论文
共 50 条
  • [41] Alternate Nucleic Acid Targets Can Be Used To Create a Composite Standard To Evaluate Clinical Performance of Nucleic Acid Amplification Tests
    Schachter, Julius
    Chernesky, Max
    JOURNAL OF CLINICAL MICROBIOLOGY, 2019, 57 (08)
  • [42] Relative distribution of West Nile virus RNA in blood compartments: implications for blood donor nucleic acid amplification technology screening
    Lai, Lori
    Lee, Tzong-Hae
    Tobler, Leslie
    Wen, Li
    Shi, Ping
    Alexander, Jeff
    Ewing, Helen
    Busch, Michael
    TRANSFUSION, 2012, 52 (02) : 447 - 454
  • [43] Detection of infections with hepatitis B virus, hepatitis C virus, and human immunodeficiency virus by analyses of dried blood spots - performance characteristics of the ARCHITECT system and two commercial assays for nucleic acid amplification
    Ross, R. Stefan
    Stambouli, Oumaima
    Gruener, Nico
    Marcus, Ulrich
    Cai, Wei
    Zhang, Weidong
    Zimmermann, Ruth
    Roggendorf, Michael
    VIROLOGY JOURNAL, 2013, 10
  • [44] Detection of infections with hepatitis B virus, hepatitis C virus, and human immunodeficiency virus by analyses of dried blood spots - performance characteristics of the ARCHITECT system and two commercial assays for nucleic acid amplification
    R Stefan Ross
    Oumaima Stambouli
    Nico Grüner
    Ulrich Marcus
    Wei Cai
    Weidong Zhang
    Ruth Zimmermann
    Michael Roggendorf
    Virology Journal, 10
  • [45] Comparison of different samples for 2019 novel coronavirus detection by nucleic acid amplification tests
    Xie, Chunbao
    Jiang, Lingxi
    Huang, Guo
    Pu, Hong
    Gong, Bo
    Lin, He
    Ma, Shi
    Chen, Xuemei
    Long, Bo
    Si, Guo
    Yu, Hua
    Jiang, Li
    Yang, Xingxiang
    Shi, Yi
    Yang, Zhenglin
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 93 : 264 - 267
  • [46] Pre-transplant screening for west nile virus by nucleic acid amplification.
    Fox, Julie D.
    Tilley, Peter A. G.
    Lee, Bonita E.
    Chui, Linda
    Preiksaitis, Jutta K.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2007, 7 : 199 - 199
  • [47] Improved detection of human immunodeficiency virus type 1 variants by analysis of replicate amplification reactions: Relevance to studies of human immunodeficiency virus type 1 vertical transmission
    Becker-Pergola, G
    Mellquist, JL
    Eshleman, JR
    Jackson, JB
    Eshleman, SH
    MOLECULAR DIAGNOSIS, 1999, 4 (04): : 261 - 268
  • [48] HUMAN-IMMUNODEFICIENCY-VIRUS DNA AMPLIFICATION AND SEROLOGY IN BLOOD-DONORS
    PERRIN, LH
    YERLY, S
    ADAMI, N
    BACHMANN, P
    BUTLERBRUNNER, E
    BURCKHARDT, J
    KAWASHIMA, E
    BLOOD, 1990, 76 (03) : 641 - 645
  • [49] First Report of Human Immunodeficiency Virus Transmission through 20-Minipool Nucleic Acid Amplification Test-Negative Blood Donation in Japan
    Sobata, R.
    Shinohara, N.
    Matsumoto, C.
    Uchida, S.
    Igarashi, S.
    Hino, S.
    Satake, M.
    Tadokoro, K.
    TRANSFUSION, 2014, 54 : 210A - 210A
  • [50] Using multiplex nucleic acid amplification tests in the diagnosis and screening for trichomonas vaginalis and mycoplasma genitalium
    Woodward, James D.
    Dalrymple-Hay, Megan
    Pelossi, Emanuela
    Patel, Raj
    INTERNATIONAL JOURNAL OF STD & AIDS, 2021, 32 (08) : 774 - 775