Comparative evaluation of 2.0-mm locking plate system vs 2.0-mm nonlocking plate system for mandibular fracture: a prospective randomized study

被引:27
|
作者
Singh, V. [1 ]
Kumar, I. [1 ]
Bhagol, A. [1 ]
机构
[1] Pt BD Sharma Univ Hlth Sci, Govt Dent Coll, Dept Oral & Maxillofacial Surg, Rohtak 124001, Haryana, India
关键词
mandibular fracture; locking; nonlocking miniplates; COATED HOLLOW-SCREW; MAXILLOMANDIBULAR FIXATION; PLATE/SCREW SYSTEM; MINIPLATE FIXATION; RECONSTRUCTION; DEFECTS;
D O I
10.1016/j.ijom.2010.11.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the efficacy of a 2.0-mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in mandibular fractures. A prospective randomized clinical trial was conducted. Patients were randomly assigned to receive 2.0-mm locking plates (group A) or 2.0-mm nonlocking plates (group B). All patients were followed up for 12 weeks postoperatively. Complications were analysed according to the type of plate used and the site of fracture. Fifty patients with 76 fractures met the inclusion criteria. Thirty-six fracture sites were treated with 2.0-mm locking plates and 40 with 2.0-mm nonlocking plates. The number of patients requiring postoperative maxillomandibular fixation was significantly higher in group B (p < 0.01); seven complications occurred representing 9% of the total. Two complications occurred in the locking group and five in the nonlocking group with complication rates equalling 6% and 13%, respectively. When comparing the overall complication rates according to plates used, the chi(2) test showed no statistically significant difference between the locking and nonlocking plates (p > 0.05). In conclusion, mandible fractures treated with 2.0-mm locking plates and 2.0-mm nonlocking plates present similar short-term complication rates.
引用
收藏
页码:372 / 377
页数:6
相关论文
共 49 条
  • [31] Study of Efficacy and the Comparison Between 2.0 mm Locking Plating System and 2.0 mm Standard Plating System in Mandibular Fractures
    Kumar B.P.
    Kumar K.A.J.
    Venkatesh V.
    Mohan A.P.
    Ramesh K.
    Mallikarjun K.
    Journal of Maxillofacial and Oral Surgery, 2015, 14 (3) : 799 - 807
  • [32] Management of Mandibular Angle Fractures by Two Conventional 2.0-mm Miniplates: A Retrospective Study of 389 Patients
    Spinelli, Giuseppe
    Lazzeri, Davide
    Arcuri, Francesco
    Valente, Domenico
    Agostini, Tommaso
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2016, 9 (03) : 206 - 210
  • [33] Effectiveness of 2.0 mm Standard and 2.0 mm Locking Miniplates in Management of Mandibular Fractures: A Clinical Comparative Study
    Shaik M.
    Subba Raju T.
    Rao N.K.
    Reddy C.K.
    Journal of Maxillofacial and Oral Surgery, 2014, 13 (1) : 47 - 52
  • [34] Comparative evaluation of a single 2.0-mm AO locking reconstruction plate with conventional miniplate osteosynthesis for treatment of linear non-comminuted fractures of symphysis and parasymphsis region of the mandible
    Hu, W.
    Agrawal, M.
    Thadani, S.
    Mukul, S. K.
    Sood, R.
    Patel, A.
    Dhanak, R.
    Tailor, S.
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2019, 120 (01) : 11 - 15
  • [35] Outcome of Repair of Distal Radial and Ulnar Fractures in Dogs Weighing 4 kg or Less Using a 1.5-mm Locking Adaption Plate or 2.0-mm Limited Contact Dynamic Compression Plate
    Nelson, Thomas A.
    Strom, Adam
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 30 (06) : 444 - 452
  • [36] Histological and histomorphometric analysis of the bone-screw interface in the mandibular body after using a 2.0-mm miniplate system: An experimental study in dogs
    dos Santos, Thiago Iafelice
    de Oliveira, Paulo Tambasco
    Rosa, Adalberto Luiz
    Barros, Valdemar Mallet da Rocha
    Papalexiou, Vula
    Sverzut, Cassio Edvard
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (11) : 2169 - 2175
  • [37] In vitro evaluation of the resistance of a 2.0-mm titanium fixation system in the sectioned angle without continuity of the inferior border of the mandible
    Trivellato, P. F. B.
    Pepato, A. O.
    Ribeiro, M. C.
    Sverzut, C. E.
    Trivellato, A. E.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (05) : 559 - 563
  • [38] Treatment of Mandibular Fractures via Transoral 2.0-mm Miniplate Fixation With 2 Weeks of Maxillomandibular Fixation: A Retrospective Study
    Longwe, Edward A.
    Zola, Malcolm B.
    Bonnick, Andrea
    Rosenberg, Dara
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (12) : 2943 - 2946
  • [39] The Use of 2.4-mm Locking Plate System in Treating Comminuted Mandibular Fracture by Firearm
    Silva Pereira, Cassiano Costa
    dos Santos, Pamela Leticia
    Gaetti Jardim, Ellen Cristina
    Garcia Junior, Idelmo Rangel
    Shinohara, Elio Hitoshi
    Araujo, Marcelo Marotta
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2012, 5 (02) : 91 - 96
  • [40] Comparative in vitro mechanical evaluation of techniques using a 2.0 mm locking fixation system for simulated fractures of the mandibular body
    de Medeiros, Raquel Correia
    de Moura, Andrezza Lauria
    Sawazaki, Renato
    Fernandes Moreira, Roger William
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (03) : 302 - 305