Modified total variation norm for the maximum a posteriori ordered subsets expectation maximization reconstruction in fan-beam SPECT brain perfusion imaging

被引:0
|
作者
Krol, Andrzej [1 ]
Yang, Zhaoxia [1 ,2 ]
Xu, Yuesheng [2 ,3 ]
Wismueller, Axel [4 ]
Feiglin, David H. [1 ]
机构
[1] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY USA
[2] Sun Yat Sen Univ, Dept Sci Comp & Comp, Guangzhou, Guangdong, Peoples R China
[3] Syracuse Univ, Dept Math, Syracuse, NY USA
[4] Univ Rochester, Dept Radiol & Biomed Engn, Rochester, NY 14627 USA
基金
美国国家卫生研究院;
关键词
anisotropic total variation regularization in MAP-OSEM; fan-beam collimator SPECT; partial volume effect;
D O I
10.1117/12.877802
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The anisotropic geometry of Fan-Beam Collimator (FBC) Single Photon Emission Tomography (SPECT) is used in brain perfusion imaging with clinical goals to quantify regional cerebral blood flow and to accurately determine the location and extent of the brain perfusion defects. One of the difficult issues that need to be addressed is partial volume effect. The purpose of this study was to minimize the partial volume effect while preserving the optimal tradeoff between noise and bias, and maintaining spatial resolution in the reconstructed images acquired in FBC geometry. We modified conventional isotropic TV (L1) norm, which has only one hyperparameter, and replaced it with two independent TV (L1u) norms (TVxy and TVz) along two orthogonal basis vectors (XY, Z) in 3D reconstruction space. We investigated if the anisotropic norm with two hyperparameters (beta xy and beta z, where z is parallel to the axis-of-rotation) performed better in FBC-SPECT reconstruction, as compared to the conventional isotropic norm with one hyperparameter (beta) only. We found that MAP-OSEM reconstruction with modified TV norm produced images with smaller partial volume effect, as compared to the conventional TV norm at a cost of slight increase in the bias and noise.
引用
收藏
页数:6
相关论文
共 11 条
  • [1] Anisotropic total variation regularization for the maximum a posteriori ordered subsets expectation maximization reconstruction in fan-beam SPECT
    Kroll, Andrzej
    Yang, Zhaoxia
    Xu, Yuesheng
    Feiglin, David
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [2] New method for tuning hyperparameter for the total variation norm in the maximum a posteriori ordered subsets expectation maximization reconstruction in SPECT myocardial perfusion imaging
    Yang, Zhaoxia
    Krol, Andrzej
    Xu, Yuesheng
    Feiglin, David H.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [3] Can Maximum-a-Posteriori Reconstruction Improve Imaging Quality on Liver Malignant Tumor PET/CT Imaging Compared With Ordered Subsets Expectation Maximization Reconstruction?
    Pang, Lifang
    Shi, Hongcheng
    Cheng, Dengfeng
    Zhang, Yiqiu
    Lv, Yang
    Hu, Debin
    Chen, Mu
    Li, Chenwei
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [4] Accelerated SPECT image reconstruction using a modified ordered subsets expectation maximization method: A fast line search strategy.
    Liu, YH
    Sinusas, AJ
    Browne, JA
    Wackers, FJT
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 239 - 239
  • [5] Optimization of ordered subsets expectation maximization (OS-EM) algorithm in cone-beam SPECT for accelerated 3D reconstruction
    Krol, A
    Feiglin, DH
    Lee, W
    Kunniyur, VR
    Salgado, RB
    Coman, IL
    Lipson, ED
    Karczewski, DA
    Thomas, FD
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S272 - S272
  • [6] Application of ordered-subsets expectation-maximization (OSEM) algorithm to cone-beam SPECT for accelerated 3D reconstruction
    Krol, A
    Feiglin, DH
    Lee, W
    Kunniyur, VR
    Salgado, RB
    Coman, LL
    Lipson, ED
    Karczewski, DA
    Thomas, FD
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3971 - 3973
  • [7] Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximum
    E. Gordon DePuey
    Srinivas Bommireddipalli
    John Clark
    Linda Thompson
    Yossi Srour
    Journal of Nuclear Cardiology, 2009, 16 : 736 - 752
  • [8] Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum
    DePuey, E. Gordon
    Bommireddipalli, Srinivas
    Clark, John
    Thompson, Linda
    Srour, Yossi
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (05) : 736 - 752
  • [9] Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection
    DePuey, E. Gordon
    Gadiraju, Ramesh
    Clark, John
    Thompson, Linda
    Anstett, Frank
    Shwartz, Shuli C.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (04) : 547 - 563
  • [10] Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” filtered backprojection
    E. Gordon DePuey
    Ramesh Gadiraju
    John Clark
    Linda Thompson
    Frank Anstett
    Shuli C. Shwartz
    Journal of Nuclear Cardiology, 2008, 15 : 547 - 563