Application of ordered-subsets expectation-maximization (OSEM) algorithm to cone-beam SPECT for accelerated 3D reconstruction

被引:0
|
作者
Krol, A [1 ]
Feiglin, DH [1 ]
Lee, W [1 ]
Kunniyur, VR [1 ]
Salgado, RB [1 ]
Coman, LL [1 ]
Lipson, ED [1 ]
Karczewski, DA [1 ]
Thomas, FD [1 ]
机构
[1] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We investigated the performance of an ordered-subsets expectation-maximization (OSEM) algorithm for accelerated reconstruction in cone-beam SPECT. SPECT scans were performed using a Defrise phantom filled with 0.9 mu Ci/ml of Tc-99m and a dual-head gamma camera equipped with one cone-beam (CBC, f = 70 cm) and one parallel-beam collimator (PBC). Images were reconstructed using a fully-3D approach with resolution and attenuation modeling and an ordered-subsets version of a maximum-likelihood expectation-maximization algorithm (MLEM). Three grouping patterns of subsets were applied: consecutive, orthogonal, and uniform. In contrast to PBC SPECT, we observe that, in CBC SPECT, the reconstruction grouping pattern of the subsets is very important for the image quality obtained. Only when the projection data grouped into a subset were selected as uniformly as possible from all the acquired views, were the image quality and the noise in the images very close to results obtained using MLEM. However, we note that, for both CBC and PBC SPECT, the loglikelihood for a given iteration is practically the same for different grouping patterns of subsets.
引用
收藏
页码:3971 / 3973
页数:3
相关论文
共 50 条
  • [1] Optimization of ordered subsets expectation maximization (OS-EM) algorithm in cone-beam SPECT for accelerated 3D reconstruction
    Krol, A
    Feiglin, DH
    Lee, W
    Kunniyur, VR
    Salgado, RB
    Coman, IL
    Lipson, ED
    Karczewski, DA
    Thomas, FD
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S272 - S272
  • [2] Development of a fully 3D system model in iterative expectation-maximization reconstruction for cone-beam SPECT
    Ye, Hongwei
    Vogelsang, Levon
    Feiglin, David H.
    Lipson, Edward D.
    Krol, Andrzej
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [3] Simultaneous 3-Dimensional Resolution Correction in SPECT Reconstruction with an Ordered-Subsets Expectation Maximization Algorithm
    Takahashi, Yasuyuki
    Murase, Kenya
    Mochizuki, Teruhito
    Sugawara, Yoshifumi
    Maeda, Hisato
    Kinda, Akiyoshi
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (01) : 34 - 38
  • [4] Pinhole SPECT using the ordered subsets expectation maximization (OSEM) algorithm.
    Vanhove, C
    Defrise, M
    Franken, PR
    Bossuyt, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1185 - 1185
  • [5] Pinhole SPECT using the ordered subsets expectation maximization (OSEM) algorithm.
    Vanhove, C
    Defrise, M
    Franken, PR
    Bossuyt, A
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 78P - 78P
  • [6] Use of ordered-subsets expectation maximization (OSEM) for lesion detection and localization in Tc-99m DMSA SPECT
    Bedel, D.
    Durmus-Altun, G.
    Ergulen, A.
    Berkarda, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S114 - S114
  • [7] Characterization of ordered-subsets expectation maximization with 3d post-reconstruction gauss filtering and comparison with filtered backprojection in99mTc SPECT
    Marco Brambilla
    Barbara Cannillo
    Marco Dominietto
    Lucia Leva
    Chiara Secco
    Eugenio Inglese
    Annals of Nuclear Medicine, 2005, 19 : 75 - 82
  • [8] Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT
    Brambilla, M
    Cannillo, B
    Dominietto, M
    Leva, L
    Secco, C
    Inglese, E
    ANNALS OF NUCLEAR MEDICINE, 2005, 19 (02) : 75 - 82
  • [9] Analytical algorithm for 3D cone-beam SPECT reconstruction with uniform attenuation correction
    Bronnikov, A.V.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1417 - 1423
  • [10] Influence of Setting of Ordered Subsets Expectation Maximization (OSEM 3D) Reconstruction on Quality of 99mTc-EDDA/HYNIC-Octreotate SPECT Images in Patients with Neuroendocrine Tumours
    Lenda-Tracz, W.
    Glowa, B.
    Hubalewska-Dydejczyk, A.
    Sowa-Staszczak, A.
    Trofimiuk, M.
    Huszno, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S402 - S402